A comprehensive investigation of the optimization cooling technique for improving the performance of PV module with reflectors under Egyptian conditions

被引:69
|
作者
Kabeel, A. E. [1 ]
Abdelgaied, Mohamed [1 ]
Sathyamurthy, Ravishankar [1 ,2 ]
机构
[1] Tanta Univ, Fac Engn, Mech Power Engn Dept, Tanta, Egypt
[2] Hindustan Inst Technol & Sci, Dept Automobile Engn, Chennai 603103, Tamil Nadu, India
关键词
PV module; Reflectors; Cooling techniques; Performance improvement; Economic study; PHOTOVOLTAIC PANEL; SOLAR-STILL; FACADE INTEGRATION; POWER-GENERATION; WATER; SYSTEMS; DESIGN; CONCENTRATOR; ENERGY; CELLS;
D O I
10.1016/j.solener.2019.05.019
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The aim of this study is to determine an optimization cooling technology for improving the performance of PV module with reflector under Egyptian conditions. For best cooling technology can be used to enhance the performance of the PV module with reflectors, a three different cooling techniques were experimentally studied as follows: use air forced cooling technology in the presence of reflectors (case-I), use water cooling technology in the presence of reflectors (case-II), and use forced-air and water cooling technologies together in the presence of reflectors (case-III). The results of the case-I, case-II, and case-III was compared to the conventional PV module to get the best cooling technique that case be used to improve the performance of the PV module with reflectors. Also, the economic analysis was studied. The results show that use water cooling technology in the presence of reflectors represents a best technology that can be used for the PV modules. The net output electricity reaches to 912, 1077, and 1010 Wh/day for case-I, II, and III, respectively. But the output electricity from the conventional PV module recorded 832 Wh/day. The gain in the net output electricity for using the reflectors and the cooling technique was recorded 80, 245, and 178 Wh/day for case-I, II, and III, respectively compared to traditional case. Furthermore, the estimated costs of kWh reached approximately 0.062, 0.072, 0.061, and 0.0722 $/kWh for the conventional case, case-I, II, and III, respectively. Finally, we recommend using water cooling technology in the presence of reflectors to improve the performance of the PV module under Egyptian conditions.
引用
收藏
页码:257 / 263
页数:7
相关论文
共 32 条
  • [21] Hybrid thermal CFD-quadrupole simulation method for estimating the cooling performance of a PV panel under natural weather conditions
    Chan-Dzib, E.
    Carrillo, J. G.
    Bassam, A.
    Lopez, L. D. Patino
    Cetina-Quinones, A. J.
    Flota-Banuelos, M.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2025, 210
  • [22] PERFORMANCE ANALYSIS OF GEO COOLING ENERGY STORAGE TECHNIQUE FOR DOMESTIC BUILDINGS IN AREAS UNDER TYPICAL WEATHER CONDITIONS
    Abbas, Zulkanain
    Abbas, Saqlain
    Shahid, Muhammad Umair
    Abbasi, Taufeeq Ur Rehman
    Hashmi, Khurram
    2021 4TH INTERNATIONAL CONFERENCE ON ENERGY CONSERVATION AND EFFICIENCY (ICECE 2021), 2021, : 83 - 86
  • [23] Experimental and Numerical Investigation of Thermal Performance of an Air-Cooled Battery Module Under High Ambient Temperature Conditions
    Sharma, Dinesh Kumar
    Prabhakar, Aneesh
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2023, 15 (09)
  • [24] A Salp-Swarm Optimization based MPPT technique for harvesting maximum energy from PV systems under partial shading conditions
    Mirza, Adeel Feroz
    Mansoor, Majad
    Ling, Qiang
    Yin, Baoqun
    Javed, M. Yaqoob
    ENERGY CONVERSION AND MANAGEMENT, 2020, 209
  • [25] Optimization assisted divide-combine approach to model cooling of a PV module equipped with TEG by using a trapezoidal shaped hybrid nano-enhanced cooling channel and performance estimation with generalized neural networks
    Selimefendigil, Fatih
    Oztop, Hakan F.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2025, 241
  • [26] Numerical investigation on the thermal performance of a flat plate solar collector using ZnO & CuO water nanofluids under Egyptian weathering conditions
    Ashour, Amr Fathy
    El-Awady, Ahmed T.
    Tawfik, Mohsen A.
    ENERGY, 2022, 240
  • [27] Optimal Performance of Dynamic Particle Swarm Optimization Based Maximum Power Trackers for Stand-Alone PV System Under Partial Shading Conditions
    Obukhov, Sergey
    Ibrahim, Ahmed
    Diab, Ahmed A. Zaki
    Al-Sumaiti, Ameena Saad
    Aboelsaud, Raef
    IEEE ACCESS, 2020, 8 (08): : 20770 - 20785
  • [28] Beyond traditional PV system: An annual study on incorporating thermal, phase change material, and thermoelectric generator technologies for performance optimization under various climatic conditions
    Benseddik, Z.
    Mortadi, M.
    Derraz, A.
    Ahachad, M.
    Radoine, H.
    Mahdaoui, M.
    APPLIED THERMAL ENGINEERING, 2025, 268
  • [29] Parametric analysis on G-PV/T collector: Performance optimization and energy trade-off among two critical structures under various outside conditions
    Li, Zhaomeng
    Ji, Jie
    Zhao, Xudong
    Li, Guiqiang
    Cui, Yu
    Song, Zhiying
    Yao, Tingting
    ENERGY, 2022, 255
  • [30] Optimization and performance investigation of confocal twin-nozzle ejector for PEMFC hydrogen supply and recirculation system under actual variable operating conditions
    Song, Yajie
    Wang, Lei
    Jia, Lei
    Wang, Xinli
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 50 : 1450 - 1464