A Constrained ICA Approach for Real-Time Cardiac Artifact Rejection in Magnetoencephalography

被引:18
作者
Breuer, Lukas [1 ]
Dammers, Juergen [1 ]
Roberts, Timothy P. L. [2 ,3 ]
Shah, N. Jon [1 ,4 ]
机构
[1] Forschungszentrum Julich, Inst Neurosci & Med INM 4, D-52425 Julich, Germany
[2] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Radiol, Perelman Sch Med, Philadelphia, PA 19104 USA
[4] Julich Aachen Res Alliance JARA Translat Brai, D-52425 Julich, Germany
关键词
Cardiac artifact rejection for real-time analysis (CARTA); constrained ICA (cICA); cross trial phase statistics (CTPS); independent component analysis (ICA); magnetoencephalography (MEG); real-time artifact reduction; INDEPENDENT COMPONENT ANALYSIS; SOURCE SEPARATION; BLIND SEPARATION; EEG-DATA; REMOVAL; IDENTIFICATION; STATISTICS; INFORMATION; ALGORITHMS; REDUCTION;
D O I
10.1109/TBME.2013.2280143
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, magnetoencephalography (MEG)-based real-time brain computing interfaces (BCI) have been developed to enable novel and promising methods of neuroscience research and therapy. Artifact rejection prior to source localization largely enhances the localization accuracy. However, many BCI approaches neglect real-time artifact removal due to its time consuming processing. With cardiac artifact rejection for real-time analysis (CARTA), we introduce a novel algorithm capable of real-time cardiac artifact (CA) rejection. The method is based on constrained independent component analysis (ICA), where a priori information of the underlying source signal is used to optimize and accelerate signal decomposition. In CARTA, this is performed by estimating the subject's individual density distribution of the cardiac activity, which leads to a subject-specific signal decomposition algorithm. We show that the new method is capable of effectively reducing CAs within one iteration and a time delay of 1 ms. In contrast, Infomax and Extended Infomax ICA converged not until seven iterations, while FastICA needs at least ten iterations. CARTA was tested and applied to data from three different but most common MEGsystems (4-D-Neuroimaging, VSM MedTech Inc., and Elekta Neuromag). Therefore, the new method contributes to reliable signal analysis utilizing BCI approaches.
引用
收藏
页码:405 / 414
页数:10
相关论文
共 44 条
[21]  
Hyvärinen A, 2001, INDEPENDENT COMPONENT ANALYSIS: PRINCIPLES AND PRACTICE, P71
[22]   Independent component analysis:: algorithms and applications [J].
Hyvärinen, A ;
Oja, E .
NEURAL NETWORKS, 2000, 13 (4-5) :411-430
[23]   Magnetic field tomography of cortical and deep processes: Examples of ''real-time mapping'' of averaged and single trial MEG signals [J].
Ioannides, AA ;
Liu, MJ ;
Liu, LC ;
Bamidis, PD ;
Hellstrand, E ;
Stephan, KM .
INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 1995, 20 (03) :161-175
[24]   Fully Automated Reduction of Ocular Artifacts in High-Dimensional Neural Data [J].
Kelly, John W. ;
Siewiorek, Daniel P. ;
Smailagic, Asim ;
Collinger, Jennifer L. ;
Weber, Douglas J. ;
Wang, Wei .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (03) :598-606
[25]   Groupwise independent component decomposition of EEG data and partial least square analysis [J].
Kovacevic, Natasa ;
McIntosh, Anthony Randal .
NEUROIMAGE, 2007, 35 (03) :1103-1112
[26]   Removal of ocular artifacts from EEG using adaptive thresholding of wavelet coefficients [J].
Krishnaveni, V. ;
Jayaraman, S. ;
Anitha, L. ;
Ramadoss, K. .
JOURNAL OF NEURAL ENGINEERING, 2006, 3 (04) :338-346
[27]   Applications of cortical signals to neuroprosthetic control: A critical review [J].
Lauer, RT ;
Peckham, PH ;
Kilgore, KL ;
Heetderks, WJ .
IEEE TRANSACTIONS ON REHABILITATION ENGINEERING, 2000, 8 (02) :205-208
[28]   Independent component analysis using an extended infomax algorithm for mixed subgaussian and supergaussian sources [J].
Lee, TW ;
Girolami, M ;
Sejnowski, TJ .
NEURAL COMPUTATION, 1999, 11 (02) :417-441
[29]   Approach and applications of constrained ICA [J].
Lu, W ;
Rajapakse, JC .
IEEE TRANSACTIONS ON NEURAL NETWORKS, 2005, 16 (01) :203-212
[30]   Improving MEG source localizations: An automated method for complete artifact removal based on independent component analysis [J].
Mantini, D. ;
Franciotti, R. ;
Romani, G. L. ;
Pizzella, V. .
NEUROIMAGE, 2008, 40 (01) :160-173