An experimental study of the thermal performance of a novel photovoltaic double-skin facade in Hong Kong

被引:131
|
作者
Peng, Jinqing [1 ]
Lu, Lin [1 ]
Yang, Hongxing [1 ]
机构
[1] Hong Kong Polytech Univ, RERG, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Building-integrated photovoltaic; See-through amorphous silicon; Solar heat gain coefficient; Building energy efficiency; HEAT-TRANSFER; ENERGY PERFORMANCE; SOLAR-CELLS; AIR-FLOW; BUILDINGS; WINDOW; SIMULATION; CHINA;
D O I
10.1016/j.solener.2013.08.031
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Ventilated building-integrated photovoltaic (BIPV) facades can not only generate electricity at the locations of buildings themselves but if designed optimally, such facades can also reduce the respective heat gains and heat losses in summer and winter via the building envelope. The development of a novel ventilated BIPV double-skin facade (DSF), constituted by a see-through amorphous silicon (a-Si) PV module and an inward opening window, is reported in this paper. In order to enhance ventilation, an air-flow duct, 400 mm in depth is situated between the outside PV module and the inside window. This ventilation design can remove much of the waste heat generated by the PV module energy conversion processes, and thus bring down the operating temperature of the solar cells. Infrared thermal imaging was adopted in relation to the ventilated PV-DSF to visually demonstrate this ventilating effect. It was found that the air temperature at the outlet louver is higher than that at the inlet louver by 2.2-2.3 degrees C. The thermal performance of PV-DSFs operating in different modes was studied and compared. The results showed that the ventilated PV-DSF provides the lowest solar heat gain coefficient (SHGC), while the non-ventilated PV-DSF better reduces heat loss. Based on the experimental results, the optimum operation strategy for the PV-DSF under different weather conditions has been determined and proposed. This novel PV-DSF is more suitable for sub-tropical climates because it results in a much lower SHGC than that of a low-e coating DSF. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:293 / 304
页数:12
相关论文
共 50 条
  • [21] Parametric study of double-skin facades performance in mild climate countries
    Alberto, Andre
    Ramos, Nuno M. M.
    Almeida, Ricardo M. S. F.
    JOURNAL OF BUILDING ENGINEERING, 2017, 12 : 87 - 98
  • [22] Numerical study of the performance for a curved double-skin fa?ade in summer
    Huang, Yi
    Tao, Yao
    Shi, Long
    Liu, Qinggong
    Wang, Yong
    Tu, Jiyuan
    Gan, Xin
    BUILDING AND ENVIRONMENT, 2023, 233
  • [23] Optimising Design Parameters of a Building-Integrated Photovoltaic Double-Skin Facade in Different Climate Zones in Australia
    Yang, Siliang
    Fiorito, Francesco
    Sproul, Alistair
    Prasad, Deo
    BUILDINGS, 2023, 13 (04)
  • [24] Investigation of energy performance of nanotechnological material and double-skin facade system in office buildings in Turkiye
    Qurraie, Bahar Sultan
    Sertyamac, Rahman
    INTELLIGENT BUILDINGS INTERNATIONAL, 2023, 15 (06) : 251 - 265
  • [25] Analytical model of semi-transparent photovoltaic double-skin facade system (STPV-DSF) for natural and forced ventilation modes
    Preet, Sajan
    Sharma, Manoj Kumar
    Mathur, Jyotirmay
    Chowdhury, Amartya
    Mathur, Sanjay
    INTERNATIONAL JOURNAL OF VENTILATION, 2023, 22 (02) : 138 - 167
  • [26] NUMERICAL AND EXPERIMENTAL STUDY ON THE THERMO-AERODYNAMIC BEHAVIOR OF A DOUBLE-SKIN GLAZED FACADE
    Grigoras, Catalin
    Popovici, Catalin George
    Mateescu, Theodor
    Chereches, Nelu-Cristian
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2014, 13 (04): : 775 - 781
  • [27] Numerical simulation study of BIPV/T double-skin facade for various climate zones in Australia: Effects on indoor thermal comfort
    Yang, Siliang
    Cannavale, Alessandro
    Prasad, Deo
    Sproul, Alistair
    Fiorito, Francesco
    BUILDING SIMULATION, 2019, 12 (01) : 51 - 67
  • [28] Thermal Performance of Double Skin Facade Windows
    He, Guoqing
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1964 - 1969
  • [29] NUMERICAL STUDIES ON SMOKE SPREAD IN THE CAVITY OF A DOUBLE-SKIN FACADE
    Chow, Cheuk Lun
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2011, 17 (03) : 371 - 392
  • [30] Modeling and Simulation of Ventilated Double-Skin Facade Using EnergyPlus
    Le, Sha
    Chen, Youming
    Bi, Yuan
    Lu, Xiang
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 3: BUILDING SIMULATION AND INFORMATION MANAGEMENT, 2014, 263 : 241 - 252