An experimental study of the thermal performance of a novel photovoltaic double-skin facade in Hong Kong

被引:131
|
作者
Peng, Jinqing [1 ]
Lu, Lin [1 ]
Yang, Hongxing [1 ]
机构
[1] Hong Kong Polytech Univ, RERG, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Building-integrated photovoltaic; See-through amorphous silicon; Solar heat gain coefficient; Building energy efficiency; HEAT-TRANSFER; ENERGY PERFORMANCE; SOLAR-CELLS; AIR-FLOW; BUILDINGS; WINDOW; SIMULATION; CHINA;
D O I
10.1016/j.solener.2013.08.031
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Ventilated building-integrated photovoltaic (BIPV) facades can not only generate electricity at the locations of buildings themselves but if designed optimally, such facades can also reduce the respective heat gains and heat losses in summer and winter via the building envelope. The development of a novel ventilated BIPV double-skin facade (DSF), constituted by a see-through amorphous silicon (a-Si) PV module and an inward opening window, is reported in this paper. In order to enhance ventilation, an air-flow duct, 400 mm in depth is situated between the outside PV module and the inside window. This ventilation design can remove much of the waste heat generated by the PV module energy conversion processes, and thus bring down the operating temperature of the solar cells. Infrared thermal imaging was adopted in relation to the ventilated PV-DSF to visually demonstrate this ventilating effect. It was found that the air temperature at the outlet louver is higher than that at the inlet louver by 2.2-2.3 degrees C. The thermal performance of PV-DSFs operating in different modes was studied and compared. The results showed that the ventilated PV-DSF provides the lowest solar heat gain coefficient (SHGC), while the non-ventilated PV-DSF better reduces heat loss. Based on the experimental results, the optimum operation strategy for the PV-DSF under different weather conditions has been determined and proposed. This novel PV-DSF is more suitable for sub-tropical climates because it results in a much lower SHGC than that of a low-e coating DSF. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:293 / 304
页数:12
相关论文
共 50 条
  • [1] Performance evaluation of photovoltaic double-skin facade with forced ventilation in the composite climate
    Preet, Sajan
    Sharma, Manoj Kumar
    Mathur, Jyotirmay
    Chowdhury, Amartya
    Mathur, Sanjay
    JOURNAL OF BUILDING ENGINEERING, 2020, 32
  • [2] Thermal performance of an innovative double-skin ventilated facade with multistep-encapsulated PCM integration
    Yang, Ruitong
    Li, Dong
    Arici, Muslum
    Salazar, Samanta Lopez
    Zhang, Chengjun
    Fu, Qiang
    Yang, Xinpeng
    Zheng, Qiye
    JOURNAL OF ENERGY STORAGE, 2023, 73
  • [3] Evaluating thermal performance of double-skin facade using response factor
    Lee, Seung Woo
    Park, J. S.
    ENERGY AND BUILDINGS, 2020, 209
  • [4] Investigation on energy performance of double skin facade in Hong Kong
    Chan, A. L. S.
    Chow, T. T.
    Fong, K. F.
    Lin, Z.
    ENERGY AND BUILDINGS, 2009, 41 (11) : 1135 - 1142
  • [5] Energy performance assessment of double-skin facade with thermal mass
    Fallahi, Ali
    Haghighat, Fariborz
    Elsadi, Hafia
    ENERGY AND BUILDINGS, 2010, 42 (09) : 1499 - 1509
  • [6] Investigating Factors Impacting Power Generation Efficiency in Photovoltaic Double-Skin Facade Curtain Walls
    Zhou, Xiaoxuan
    Zhou, Xue
    Zhu, Xiangyuan
    Liu, Jiying
    Zhou, Shiyu
    BUILDINGS, 2024, 14 (09)
  • [7] A method to describe the thermal property of pipe-embedded double-skin facade: Equivalent glass window
    Yan, Shuai
    Li, Xianting
    Wang, Baolong
    Shi, Wenxing
    Lyu, Weihua
    ENERGY AND BUILDINGS, 2019, 195 : 33 - 44
  • [8] A theoretical model of natural ventilation enhanced by solar thermal energy in double-skin facade
    Tao, Yao
    Yan, Yihuan
    Chew, Michael Yit Lin
    Tu, Jiyuan
    Shi, Long
    ENERGY, 2023, 276
  • [9] Experimental Study on Impact of Ventilated Double-Skin Facade on the Indoor Thermal Environment in Winter
    Yang, Hua
    Feng, Xiyang
    Xia, Guoqiang
    Wan, Qianzhao
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 1: INDOOR AND OUTDOOR ENVIRONMENT, 2014, 261 : 523 - 531
  • [10] Summertime thermal and energy performance of a double-skin green facade: A case study in Shanghai
    Yang, Feng
    Yuan, Feng
    Qian, Feng
    Zhuang, Zhi
    Yao, Jiawei
    SUSTAINABLE CITIES AND SOCIETY, 2018, 39 : 43 - 51