Polyethylene moderator optimized for increasing thermal neutron flux in the NASBEE accelerator-based neutron field

被引:5
作者
Ogawara, Ryo [1 ,2 ,3 ,4 ]
Kusumoto, Tamon [4 ,5 ]
Konishi, Teruaki [5 ]
Hamano, Tsuyoshi [1 ]
Kodaira, Satoshi [4 ,5 ]
机构
[1] Natl Inst Quantum & Radiol Sci & Technol, Natl Inst Radiol Sci, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
[2] Kyoto Univ, Adv Res Ctr Beam Sci, Inst Chem Res, Uji, Kyoto 6110011, Japan
[3] RIKEN, Nishina Ctr Accelerator Based Sci, Wako, Saitama 3510198, Japan
[4] Natl Inst Quantum & Radiol Sci & Technol, Ctr Adv Radiat Emergency Med, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
[5] Natl Inst Quantum & Radiol Sci & Technol, Inst Quantum Life Sci, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
关键词
Accelerator-based neutron field; Thermal neutron; Boron neutron capture therapy; Neutron moderator; CAPTURE THERAPY; DETECTOR;
D O I
10.1016/j.radmeas.2020.106358
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) at National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology (NIRS-QST) achieved thermal neutron flux of a therapeutic intensity of (1.75 +/- 0.13) x 10(9) cm(-2) s(-1) by optimizing polyethylene (PE) moderator in the beam port. The dose contamination of gamma rays was 2.37 x 10(-12) Gy cm(2) (the absorbed dose of 14.9 Gy h(-1)). The improved thermal neutron field at the NASBEE facility will be useful in the research and development for boron neutron capture therapy (BNCT).
引用
收藏
页数:4
相关论文
共 27 条
[1]   FIRST EVALUATION OF THE BIOLOGIC EFFECTIVENESS FACTORS OF BORON NEUTRON CAPTURE THERAPY (BNCT) IN A HUMAN COLON CARCINOMA CELL LINE [J].
Alejandra Dagrosa, Maria ;
Crivello, Martin ;
Perona, Marina ;
Thorp, Silvia ;
Alberto Santa Cruz, Gustavo ;
Pozzi, Emiliano ;
Casal, Mariana ;
Thomasz, Lisa ;
Cabrini, Romulo ;
Kahl, Steven ;
Juan Juvenal, Guillermo ;
Alberto Pisarev, Mario .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (01) :262-268
[2]  
Fairchild R.G., 2020, RAD MEASUREMENTS, V137
[3]  
Fukumura Akifumi, 2012, Igaku Butsuri, V32, P182
[4]   Measurement of the thick-target 9Be(p,n) neutron energy spectra [J].
Howard, WB ;
Grimes, SM ;
Massey, TN ;
Al-Quraishi, SI ;
Jacobs, DK ;
Brient, CE ;
Yanch, JC .
NUCLEAR SCIENCE AND ENGINEERING, 2001, 138 (02) :145-160
[5]  
IAEA publications, 2008, IAEA TECHN REP SER, V461
[6]  
IAEA publications, 2001, IAEATECDOC1223
[7]   Development of thermal neutron moderator for testing boron agents for Boron Neutron Capture Therapy (BNCT) [J].
Ichikawa, G. ;
Tsuchida, K. ;
Kiyanagi, Y. ;
Ishikawa, A. ;
Hirata, Y. ;
Yoshihashi, S. ;
Watanabe, K. ;
Uritani, A. ;
Hamano, T. ;
Ogawara, R. ;
Suda, M. ;
Igawa, K. .
JOURNAL OF INSTRUMENTATION, 2019, 14
[8]   Sensitivity and linearity of optical fiber-based neutron detectors using small 6Li-based scintillators [J].
Ishikawa, Akihisa ;
Yamazaki, Atsushi ;
Watanabe, Kenichi ;
Yoshihashi, Sachiko ;
Uritani, Akira ;
Fukuda, Kentaro ;
Koike, Akifumi ;
Ogawara, Ryo ;
Suda, Mitsuru ;
Hamano, Tsuyoshi .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954
[9]  
Ishikawa M., 2016, ONCOLOGY, V11, P105
[10]   Neutron-induced thermoluminescence properties of Tb3+-doped CaO-Al2O3-B2O3 glasses [J].
Kawamura, Ichiro ;
Kawamoto, Hiroki ;
Fujimoto, Yutaka ;
Koshimizu, Masanori ;
Okada, Go ;
Koba, Yusuke ;
Ogawara, Ryo ;
Yanagida, Takayuki ;
Asai, Keisuke .
JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 2019, 127 (10) :663-668