3-D Finite-Element Method for Calculating the Ionized Electric Field and the Ion Current of the Human Body Model Under the UHVDC Lines

被引:22
作者
Zhen, Yongzan [1 ,2 ]
Cui, Xiang [1 ]
Lu, Tiebing [1 ]
Li, Xuebao [1 ]
Fang, Chao [1 ]
Zhou, Xiangxian [1 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, Postdoctoral Res Stn Management Sci & Engn, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
Finite-element method (FEM); human body; high-voltage direct current (HVDC); ion current; TRANSMISSION-LINES; CURRENT-DENSITY;
D O I
10.1109/TPWRD.2012.2234767
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As ultra-high-voltage direct current (UHVDC) projects are constructed in China, the electromagnetic environment problem is widely concerned. One of the most important problems is the ion-flow field including the human body under the UHVDC lines. But it has not been analyzed sufficiently. In this paper, the 3-D upstream finite-element method, a new method to analyze the 3-D ion-flow field under HVDC lines is proposed and verified by experiments. Then, the method is used to calculate the ionized electric field and the ion current of the human body model under the UHVDC lines. The ionized electric field is significantly distorted by the human body. According to the results, the ionized electric field and the ion current of the human body remarkably increase with the height of the human body model. The results could provide a reference for evaluating the electromagnetic environment and the personal feeling test under the UHVDC lines.
引用
收藏
页码:965 / 971
页数:7
相关论文
共 9 条
[1]   TRANSMISSION-LINE ELECTRIC-FIELD INDUCTION IN HUMANS USING CHARGE SIMULATION METHOD [J].
ABDELSALAM, M ;
ABDALLAH, HM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (11) :1105-1109
[2]   Corona power loss, electric field, and current density profiles in bundled horizontal and vertical bipolar conductors [J].
Al-Hamouz, ZM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2002, 38 (05) :1182-1189
[3]  
Jin Jianming, 2002, FINITE ELEMENT METHO, P165
[4]  
Li X, 1995, IEEE 1995 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, P455, DOI 10.1109/CEIDP.1995.483761
[5]   Analysis of the electric field and ion current density under ultra high-voltage direct-current transmission lines based on finite element method [J].
Lu, Tiebing ;
Feng, Han ;
Zhao, Zhibin ;
Cui, Xiang .
IEEE TRANSACTIONS ON MAGNETICS, 2007, 43 (04) :1221-1224
[6]  
Sarma M. P, 2000, CORONA PERFORMANCE H, P3
[7]   CALCULATION OF ION FLOW-FIELDS OF HVDC TRANSMISSION-LINES BY THE FINITE-ELEMENT METHOD [J].
TAKUMA, T ;
IKEDA, T ;
KAWAMOTO, T .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (12) :4802-4810
[8]  
YAMASHITA M, 1994, IEICE T COMMUN, VE77B, P714
[9]  
Zhang B., 2010, IEEE C EL FIELD COMP