Microfabricated devices for capillary electrophoresis-electrospray mass spectrometry

被引:210
作者
Zhang, B
Liu, H
Karger, BL
Foret, F [1 ]
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
关键词
D O I
10.1021/ac990090u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two fundamental approaches for the coupling of microfabricated devices to electrospray mass spectrometry (ESI-MS) have been developed and evaluated. The microdevices, designed for electrophoretic separation, were constructed from glass by standard photolithographic/wet chemical etching techniques. Both approaches integrated sample inlet ports, preconcentration sample loops, the separation channel, and a port for ESI coupling. In one design, a modular, reusable microdevice was coupled to an external subatmospheric electrospray interface using a liquid junction and a fused silica transfer capillary. The transfer capillary allowed the use of an independent electrospray interface as well as fiber optic UV detection. In the second design, a miniaturized pneumatic nebulizer was fabricated as an integral part of the chip, resulting in a very simple device, The on-chip pneumatic nebulizer provided control of the flow of the electrosprayed liquid and minimized the dead volume associated with droplet formation at the electrospray exit port. Thus, the microdevice substituted for a capillary electrophoresis instrument and an electrospray interface-traditionally two independent components. This type of microdevice is simple to fabricate and may thus be developed either as a part of a reusable system or as a disposable cartridge, Both devices were tested on CE separations of angiotensin peptides and a cytochrome c tryptic digest. Several electrolyte systems including a transient isotachophoretic preconcentration step were tested for separation and analysis by an ion trap mass spectrometer.
引用
收藏
页码:3258 / 3264
页数:7
相关论文
共 39 条
[1]  
BING NH, 1998, P MU TAS 98 BAN CAN, P141
[2]   Preparation and hybridization analysis of DNA/RNA from E-coli on microfabricated bioelectronic chips [J].
Cheng, J ;
Sheldon, EL ;
Wu, L ;
Uribe, A ;
Gerrue, LO ;
Carrino, J ;
Heller, MJ ;
O'Connell, JP .
NATURE BIOTECHNOLOGY, 1998, 16 (06) :541-546
[3]   Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline [J].
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :373-378
[4]   Dispersion sources for compact geometries on microchips [J].
Culbertson, CT ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3781-3789
[5]  
Desai A, 1997, TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, P927, DOI 10.1109/SENSOR.1997.635254
[6]   HIGH-SPEED SEPARATION OF ANTISENSE OLIGONUCLEOTIDES ON A MICROMACHINED CAPILLARY ELECTROPHORESIS DEVICE [J].
EFFENHAUSER, CS ;
PAULUS, A ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2949-2953
[7]   A microfabricated device for rapid protein identification by microelectrospray ion trap mass spectrometry [J].
Figeys, D ;
Ning, YB ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3153-3160
[8]   Nanoflow solvent gradient delivery from a microfabricated device for protein identifications by electrospray ionization mass spectrometry [J].
Figeys, D ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3721-3727
[9]   TRACE ANALYSIS OF PROTEINS BY CAPILLARY ZONE ELECTROPHORESIS WITH ON-COLUMN TRANSIENT ISOTACHOPHORETIC PRECONCENTRATION [J].
FORET, F ;
SZOKO, E ;
KARGER, BL .
ELECTROPHORESIS, 1993, 14 (5-6) :417-428
[10]  
FORET F, 1996, P 44 ASMS C MASS SPE, P913