Subjective indoor air quality in schools in relation to exposure

被引:76
作者
Smedje, G
Norback, D
Edling, C
机构
[1] Department of Occupational and Environmental Medicine, University Hospital
关键词
subjective air quality; school personnel; personal factors; building characteristics; VOC; microorganisms;
D O I
10.1111/j.1600-0668.1997.00009.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This payer presents data on indoor air quality in schools as perceived by those working in them and relates these data to exposure measurements. Data on subjective air quality, domestic exposures and health aspects were gathered by means of a questionnaire which was sent to all personnel in 38 schools; it was completed by 1410 persons (85% of the total). Data on exposure were gathered by exposure measurements in classrooms. The ree suits indicate that 53% of the personnel perceived the indoor air quality as bad or very bad. It was perceived as worse by those who were younger, those who were dissatisfied with their psychosocial work climate and those who were not exposed to tobacco smoke at home. In older school buildings and buildings with displacement ventilation there was less dissatisfaction with the air quality. There were no significant relations between complaints and air exchange rate or concentration of carbon dioxide. The air quality was perceived as worse at higher levels of exposure to a number of airborne compounds including volatile organic compounds, moulds, bacteria and respirable dust. It was concluded that exposure to indoor pollutants affects perception even at the low concentrations normally found indoors in nonindustrial buildings. (C) Indoor Air (1997).
引用
收藏
页码:143 / 150
页数:8
相关论文
共 35 条
  • [1] HUMAN RESPONSE TO 78-HOUR EXPOSURE TO DRY AIR
    ANDERSEN, I
    LUNDQVIST, GR
    JENSEN, PL
    PROCTOR, DF
    [J]. ARCHIVES OF ENVIRONMENTAL HEALTH, 1974, 29 (06): : 319 - 324
  • [2] CHEMOSORPTION SAMPLING AND ANALYSIS OF FORMALDEHYDE IN AIR - INFLUENCE ON RECOVERY DURING THE SIMULTANEOUS SAMPLING OF FORMALDEHYDE, PHENOL, FURFURAL AND FURFURYL ALCOHOL
    ANDERSSON, K
    HALLGREN, C
    LEVIN, JO
    NILSSON, CA
    [J]. SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1981, 7 (04) : 282 - 289
  • [3] Anundi H, 1992, P 41 NORD M WORK ENV, P227
  • [4] DISTINGUISHING BETWEEN HEALTHY AND SICK PRESCHOOLS BY CHEMICAL CLASSIFICATION
    BAIRD, JC
    BERGLUND, B
    BERGLUND, U
    NICANDERBREDBERG, H
    NOMA, E
    [J]. ENVIRONMENT INTERNATIONAL, 1987, 13 (02) : 167 - 174
  • [5] Berglund B, 1982, ENVIRON INT, V8, P327
  • [6] RESULTS IN DUST SAMPLES WITH A NEW QUANTITATIVE GUANINE ASSESSMENT AND EVALUATING OF RISK GROUPS
    BISCHOFF, ERC
    KNIEST, FM
    SCHIRMACHER, W
    [J]. ENVIRONMENTAL TECHNOLOGY, 1992, 13 (04) : 377 - 382
  • [7] Broder I, 1993, VOLATILE ORGANIC COM, P595
  • [8] SICK BUILDING SYNDROME - A STUDY OF 4373 OFFICE WORKERS
    BURGE, S
    HEDGE, A
    WILSON, S
    BASS, JH
    ROBERTSON, A
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 1987, 31 (04) : 493 - 504
  • [10] GEBSKI V, 1992, SPIDA USERS MANUAL