Parallel On-Chip Analysis of Single Vesicle Neurotransmitter Release

被引:46
|
作者
Yakushenko, Alexey [1 ,2 ]
Kaetelhoen, Enno [1 ,2 ]
Wolfrum, Bernhard [1 ,2 ,3 ]
机构
[1] Forschungszentrum Julich, Inst Bioelect PGI 8 ICS 8, D-52425 Julich, Germany
[2] Forschungszentrum Julich, JARA Fundamentals Future Informat Technol, D-52425 Julich, Germany
[3] Rhein Westfal TH Aachen, Inst Phys 4, D-52074 Aachen, Germany
关键词
ELECTROCHEMICAL DETECTION; DOPAMINE RELEASE; EXOCYTOSIS; CELLS; MICROELECTRODES; NEURONS; ARRAY; TRANSMITTER; MICROSCOPY; CHEMISTRY;
D O I
10.1021/ac4006183
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Real-time investigations of neurotransmitter release provide a direct insight on the mechanisms involved in synaptic communication. Carbon fiber microelectrodes are state-of-the-art tools for electrochemical measurements of. single vesicle: neurotransmitter release. Yet, they lack high-throughput capabilities, that are required for collecting robust. statistically, significant data across multiple samples. Here, we present a chip-based recording system enabling parallel in vitro measurements of individual, neurotransmitter release events from cells, cultured directly on planar multielectrode arrays. The applicability of this cell-based platform to Pharmacological screening is demonstrated by resolving minute concentration-dependent effects of the dopamine reuptake inhibitor nomifensine on recorded single-vesicle release events from PC12 cells. The experimental results, showing an increased time of the recorded events, are complemented by an analytical model for the verification of drug action.
引用
收藏
页码:5483 / 5490
页数:8
相关论文
共 50 条
  • [31] Parallel vs. Serial On-Chip Communication
    Dobkin, Rostislav
    Morgenshtein, Arkadiy
    Kolodny, Avinoam
    Ginosar, Ran
    SLIP '08: PROCEEDINGS OF THE 2008 ACM INTERNATIONAL WORKSHOP ON SYSTEM LEVEL INTERCONNECT PREDICTION, 2008, : 43 - 50
  • [32] Quantum-inspired on-chip parallel processors
    Fujishima, M
    NOISE AND INFORMATION IN NANOELECTRONICS, SENSORS, AND STANDARDS II, 2004, 5472 : 214 - 224
  • [33] EEPROM ON-CHIP SINGLE-CHIP MICROCOMPUTER.
    Matsubara, Kiyoshi
    Arai, Tamotsu
    Hitachi Review, 1986, 35 (05): : 237 - 240
  • [34] THE SYNAPTIC VESICLE CLUSTER: A SOURCE OF ENDOCYTIC PROTEINS DURING NEUROTRANSMITTER RELEASE
    Shupliakov, O.
    NEUROSCIENCE, 2009, 158 (01) : 204 - 210
  • [35] One-vesicle hypothesis for neurotransmitter release: A possible molecular mechanism
    K. Yusim
    H. Parnas
    L. A. Segel
    Bulletin of Mathematical Biology, 2001, 63 : 1025 - 1040
  • [36] One-vesicle hypothesis for neurotransmitter release: a possible molecular mechanism
    Yusim, K
    Parnas, H
    Segel, LA
    BULLETIN OF MATHEMATICAL BIOLOGY, 2001, 63 (06) : 1025 - 1040
  • [37] Involvement of β-adrenergic receptor in synaptic vesicle swelling and implication in neurotransmitter release
    Chen, Zhi Hui
    Lee, Jin-Sook
    Shin, Leah
    Cho, Won Jin
    Jena, Bhanu P.
    JOURNAL OF CELLULAR AND MOLECULAR MEDICINE, 2011, 15 (03) : 572 - 576
  • [38] Synaptic Vesicle Recycling Pathway Determines Neurotransmitter Content and Release Properties
    Silm, Katlin
    Yang, Jing
    Marcott, Pamela F.
    Asensio, Cedric S.
    Eriksen, Jacob
    Guthrie, Daryl A.
    Newman, Amy H.
    Ford, Christopher P.
    Edwards, Robert H.
    NEURON, 2019, 102 (04) : 786 - +
  • [39] Molecular analysis of neurotransmitter release
    Schiavo, G
    Stenbeck, G
    ESSAYS IN BIOCHEMISTRY, VOL 33, 1998, 1998, 33 : 29 - 41
  • [40] Molecular analysis of neurotransmitter release
    Sudhof, TC
    FASEB JOURNAL, 1997, 11 (09): : A1447 - A1447