Measurement of active content in escitalopram tablets by a near-infrared transmission spectroscopy model that encompasses batch variability

被引:5
作者
Warnecke, Solveig [1 ]
Rinnan, Asmund [1 ]
Alleso, Morten [2 ]
Engelsen, Soren Balling [1 ]
机构
[1] Univ Copenhagen, Dept Food Sci, Fac Sci, DK-1958 Frederiksberg C, Denmark
[2] H Lundbeck & Co AS, Biol & Pharmaceut Sci, DK-2500 Valby, Denmark
关键词
near-infrared spectroscopy; HPLC; content uniformity; partial least squares regression; multivariate analysis; theory of sampling; active pharmaceutical ingredient; sampling error; PROCESS ANALYTICAL TECHNOLOGY; DISCRETE MATERIALS; REFLECTANCE SPECTROSCOPY; DIMENSIONAL OBJECTS; NIR SPECTROSCOPY; QUANTITATION; TRANSMITTANCE; VALIDATION; SUBSTANCE; SPECTRA;
D O I
10.1002/jps.23461
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Near-infrared transmission (NIT) spectroscopy, with high-performance liquid chromatography as reference method, was used to study the variation of the active pharmaceutical ingredient (API), escitalopram, in five tablet batches (4%12%, w/w) manufactured by direct compression. This study investigates the influence of sample orientation, powder segregation, and compression force on the NIT spectra. For this purpose, tablet samples were taken at six different production time points, at three different compression forces, and presented to the spectrometer in four different orientations and in three spectroscopic replicates. A total set of 2160 NIT spectra was recorded. The variances between the spectra at each level of API content were thoroughly investigated by partial least squares regression using theory of sampling. The results show that a minimum of 18 tablets from each level of API content is required to establish a robust NIT calibration. The identified number of spectra is required for covering small differences in the spatial heterogeneity of the API as well as minor variations in optical properties, due to variations in the tablet compression force. NIT spectroscopy is demonstrated to be a powerful technique not only for measuring the API content in escitalopram tablets but also for routine content uniformity analysis. (c) 2013 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 102:12681280, 2013
引用
收藏
页码:1268 / 1280
页数:13
相关论文
共 31 条
[21]   Interval partial least-squares regression (iPLS):: A comparative chemometric study with an example from near-infrared spectroscopy [J].
Norgaard, L ;
Saudland, A ;
Wagner, J ;
Nielsen, JP ;
Munck, L ;
Engelsen, SB .
APPLIED SPECTROSCOPY, 2000, 54 (03) :413-419
[22]   Review of the most common pre-processing techniques for near-infrared spectra [J].
Rinnan, Asmund ;
van den Berg, Frans ;
Engelsen, Soren Balling .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2009, 28 (10) :1201-1222
[23]   Near-infrared reflectance spectroscopy as a process analytical technology tool in Ginkgo biloba extract qualification [J].
Rosa, Silvia S. ;
Barata, Pedro A. ;
Martins, Jose M. ;
Menezes, Jose C. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (02) :320-327
[24]   Assessment of Diffuse Transmission Mode in Near-Infrared Quantification-Part I: The Press Effect on Low-Dose Pharmaceutical Tablets [J].
Saeed, M. ;
Saner, S. ;
Oelichmann, J. ;
Keller, H. ;
Betz, G. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2009, 98 (12) :4877-4886
[25]   Process analytical technology: Chemometric analysis of Raman and near infra-red spectroscopic data for predicting physical properties of extended release matrix tablets [J].
Shah, Rakh B. ;
Tawakkul, Mobin A. ;
Khan, Mansoor A. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2007, 96 (05) :1356-1365
[26]  
Sheskey P.J., 2009, Handbook of Pharmaceutical Excipients, V6th
[27]   Methods for minimizing segregation: A review [J].
Tang, P ;
Puri, VM .
PARTICULATE SCIENCE AND TECHNOLOGY, 2004, 22 (04) :321-337
[28]   A comparison of reflectance and transmittance near-infrared spectroscopic techniques in determining drug content in intact tablets [J].
Thosar, SS ;
Forbess, RA ;
Ebube, NK ;
Chen, YX ;
Rubinovitz, RL ;
Kemper, MS ;
Reier, GE ;
Wheatley, TA ;
Shukla, AJ .
PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2001, 6 (01) :19-29
[29]   Protein heterogeneity in wheat lots using single-seed NIT - A Theory of Sampling (TOS) breakdown of all sampling and analytical errors [J].
Tonning, Erik ;
Norgaard, Lars ;
Engelsen, Soren B. ;
Pedersen, Lene ;
Esbensen, Kim H. .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2006, 84 (1-2) :142-152
[30]  
WOLD S, 1983, LECT NOTES MATH, V973, P286