Intraoperative and early postoperative colour Doppler sonography after carotid artery reconstruction: Follow-up of technical defects

被引:9
作者
Dorffner, R
Metz, VM
Trattnig, S
Eibenberger, K
Dock, W
Hormann, M
Trubel, W
Grabenwoger, F
机构
[1] Department of Radiology, University of Vienna, AKH, A-1090 Vienna
关键词
sonography; intraoperative; colour-coded Doppler; carotid artery reconstruction;
D O I
10.1007/s002340050377
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We studied 50 patients with intraoperative colour-coded Doppler sonography (CCDS) after carotid artery reconstruction. Technical defects could be detected in 19 cases (38 %): residual plaques in 9, naps in 8 and strictures in 2. In 9 cases (18 %) the carotid endarterectomy was revised. One residual plaque and one residual stricture caused thrombosis at the operative site a few hours postoperatively. One of the patients with residual plaques developed a high-grade stenosis within the follow-up period. Of the patients with residual plaques two had a medium-grade stenosis at follow-up. Six flaps decreased in size or disappeared within 1 week after operation. No patient with a flap developed a stenosis within the follow-up period. Our findings seem to indicate that correction of intimal flaps less than 10 mm in size is not necessary.
引用
收藏
页码:117 / 121
页数:5
相关论文
共 14 条
[1]   INTRAOPERATIVE DUPLEX SCANNING AND LATE CAROTID-ARTERY STENOSIS [J].
BAKER, WH ;
KOUSTAS, G ;
BURKE, K ;
LITTOOY, FN ;
GREISLER, HP .
JOURNAL OF VASCULAR SURGERY, 1994, 19 (05) :829-833
[2]   CAROTID SONOGRAPHY [J].
CARROLL, BA .
RADIOLOGY, 1991, 178 (02) :303-313
[3]  
FLANIGAN DP, 1986, SURGERY, V100, P893
[4]  
Foldes M S, 1993, J Vasc Nurs, V11, P108
[5]   THE IMPORTANCE OF INTRAOPERATIVE DETECTION OF RESIDUAL FLOW ABNORMALITIES AFTER CAROTID-ARTERY ENDARTERECTOMY [J].
KINNEY, EV ;
SEABROOK, GR ;
KINNEY, LY ;
BANDYK, DF ;
TOWNE, JB .
JOURNAL OF VASCULAR SURGERY, 1993, 17 (05) :912-923
[6]  
LANE RJ, 1982, SURGERY, V92, P5
[7]   OPERATIVE COLOR DOPPLER IMAGING FOR VASCULAR-SURGERY [J].
MACHI, J ;
SIGEL, B ;
ROBERTS, A ;
BAKSHI, KR ;
KODAMA, I ;
LOIACONO, LA .
JOURNAL OF ULTRASOUND IN MEDICINE, 1992, 11 (02) :65-71
[8]   AIR ALONG NEW POLYTETRAFLUOROETHYLENE GRAFTS - INABILITY TO DEMONSTRATE FLOW WITH DOPPLER SONOGRAPHY [J].
NAZARIAN, GK ;
FINLAY, DE ;
SCHWABACHER, SM ;
LETOURNEAU, JG .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (01) :144-146
[9]   RECURRENT CAROTID STENOSIS - A CONSEQUENCE OF LOCAL OR SYSTEMIC FACTORS - THE INFLUENCE OF UNREPAIRED TECHNICAL DEFECTS [J].
REILLY, LM ;
OKUHN, SP ;
RAPP, JH ;
BENNETT, JB ;
EHRENFELD, WK ;
GOLDSTONE, J ;
STONEY, RJ .
JOURNAL OF VASCULAR SURGERY, 1990, 11 (03) :448-460
[10]   INTRAOPERATIVE ARTERIOGRAPHY AND CAROTID SURGERY [J].
ROON, AJ ;
HOOGERWERF, D .
JOURNAL OF VASCULAR SURGERY, 1992, 16 (02) :239-243