摘要
The paper presents model devices for magnetic water treatment, optimized for scale control at water capacities up to a few m(3)/h. Different arrangements of permanent magnets were investigated and simulated at different water-flow capacities to yield the proper magnetic field distribution and the required magnetic flux density, using the computational program OPERA 15R1 (Vector Fields Software) with the finite-element method, considering the real 3D-geometry, non-linearity of magnetic properties of construction materials, and the interaction of neighbouring poles. (Received in October 2011, accepted in April 2012. This paper was with the authors 2 months for 1 revision.)
引用
收藏
页码:141 / 149
页数:9
相关论文
共 25 条
  • [1] Monitoring of aggregation and scaling of calcium carbonate in the presence of ultrasound irradiation using focused beam reflectance measurement
    Al Nasser, Waleed N.
    Pitt, Kate
    Hounslow, Michael J.
    Salman, Agba D.
    [J]. POWDER TECHNOLOGY, 2013, 238 : 151 - 160
  • [2] Effect of magnetic water treatment on calcium carbonate precipitation: Influence of the pipe material
    Alimi, F.
    Tlili, M. M.
    Ben Amor, M.
    Maurin, G.
    Gabrielli, C.
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2009, 48 (08) : 1327 - 1332
  • [3] Effect of the magnetic field on the growth rate of aragonite and the precipitation of CaCO3
    Chang, Meng-Chun
    Tai, Clifford Y.
    [J]. CHEMICAL ENGINEERING JOURNAL, 2010, 164 (01) : 1 - 9
  • [4] Magnetic water treatment
    Coey, JMD
    Cass, S
    [J]. JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2000, 209 (1-3) : 71 - 74
  • [5] Magnetic water treatment for scale prevention
    Gabrielli, C
    Jaouhari, R
    Maurin, G
    Keddam, M
    [J]. WATER RESEARCH, 2001, 35 (13) : 3249 - 3259
  • [6] Gusel L, 2009, METALURGIJA, V48, P103
  • [7] Jesenik M., 2006, Przeglad Elektrotechniczny, V82, P20
  • [8] Magnetic water treatment for scale control in heating and alkaline conditions
    Kozic, Viljem
    Hamler, Anton
    Ban, Irena
    Lipus, Lucija C.
    [J]. DESALINATION AND WATER TREATMENT, 2010, 22 (1-3) : 65 - 71
  • [9] Velocity effect on electronic-antifouling technology to mitigate mineral fouling in enhanced-tube heat exchanger
    Lee, SH
    Cho, YI
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (20) : 4163 - 4174
  • [10] Influence of magnetic field on the aragonite precipitation
    Lipus, L. C.
    Dobersek, D.
    [J]. CHEMICAL ENGINEERING SCIENCE, 2007, 62 (07) : 2089 - 2095