QUANTITATIVE EVALUATION OF RETINAL TUMOR VOLUME IN MOUSE MODEL OF RETINOBLASTOMA BY USING ULTRA HIGH-RESOLUTION OPTICAL COHERENCE TOMOGRAPHY

被引:4
作者
Ruggeri, Marco [1 ]
Wehbe, Hassan [1 ]
Tsechpenakis, Gavriil [2 ]
Jiao, Shuliang [1 ]
Jockovich, Maria Elena [1 ]
Cebulla, Colleen [1 ]
Hernandez, Eleut [1 ]
Murray, Timothy G. [1 ]
Puliafito, Carmen A. [1 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[2] Univ Miami, Dept Elect & Comp Engn, Coral Gables, FL 33124 USA
关键词
3D imaging; retina; mouse models; optical coherence tomography; image segmentation;
D O I
10.1142/S1793545808000066
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An ultra high resolution spectral-domain optical coherence tomography (SD-OCT) together with an advanced animal restraint and positioning system was built for noninvasive non-contact in vivo three-dimensional imaging of rodent models of ocular diseases. The animal positioning system allowed the operator to rapidly locate and switch the areas of interest on the retina. This function together with the capability of precise spatial registration provided by the generated OCT fundus image allows the system to locate and compare the same lesion (retinal tumor in the current study) at different time point throughout the entire course of the disease progression. An algorithm for fully automatic segmentation of the tumor boundaries and calculation of tumor volume was developed. The system and algorithm were successfully applied to monitoring retinal tumor growth quantitatively over time in the LHBETATAG mouse model of retinoblastoma.
引用
收藏
页码:17 / 28
页数:12
相关论文
共 17 条
  • [1] MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY
    FERCHER, AF
    HITZENBERGER, CK
    KAMP, G
    ELZAIAT, SY
    [J]. OPTICS COMMUNICATIONS, 1995, 117 (1-2) : 43 - 48
  • [2] Hartl I, 2001, INVEST OPHTH VIS SCI, V42, pS793
  • [3] Horio N, 2001, ARCH OPHTHALMOL-CHIC, V119, P1329
  • [4] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [5] Simultaneous acquisition of sectional and fundus ophthalmic images with spectral-domain optical coherence tomography
    Jiao, SL
    Knighton, R
    Huang, XR
    Gregori, G
    Puliafito, CA
    [J]. OPTICS EXPRESS, 2005, 13 (02): : 444 - 452
  • [6] KIM K, 2006, OPTICAL COHERENCE TO
  • [7] Li QH, 2001, INVEST OPHTH VIS SCI, V42, P2981
  • [8] PENDERGRASS TW, 1980, ARCH OPHTHALMOL-CHIC, V98, P1204
  • [9] A SCHEMATIC EYE FOR THE MOUSE, AND COMPARISONS WITH THE RAT
    REMTULLA, S
    HALLETT, PE
    [J]. VISION RESEARCH, 1985, 25 (01) : 21 - 31
  • [10] In vivo three-dimensional high-resolution imaging of rodent retina with spectral-domain optical coherence tomography
    Ruggeri, Marco
    Webbe, Hassan
    Jiao, Shuliang
    Gregori, Giovanni
    Jockovich, Maria E.
    Hackam, Abigail
    Duan, Yuanli
    Puliafito, Carmen A.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (04) : 1808 - 1814