Controversies in Intramedullary Fixation for Intertrochanteric Hip Fractures

被引:27
|
作者
Baldwin, Paul C., III [1 ]
Lavender, Randy C. [1 ]
Sanders, Roy [2 ]
Koval, Kenneth J. [1 ]
机构
[1] Orlando Hlth, Orlando Reg Med Ctr, Dept Orthopaed Surg, Level One Orthopaed,1222 South Orange Ave, Orlando, FL 32806 USA
[2] Univ S Florida, Florida Orthopaed Inst, Dept Orthopaed Surg, Tampa, FL USA
关键词
hip fracture; pertrochanteric femur fracture; intertrochanteric hip fracture; pertrochanteric hip fracture; cephalomedullary nail; intramedullary nail; LONG CEPHALOMEDULLARY NAILS; GAMMA-NAIL; PERTROCHANTERIC FRACTURES; FEMORAL FRACTURES; SCREW FIXATION; LAG SCREWS; FEMUR; COMPRESSION; COMPLICATIONS; INTERTAN;
D O I
10.1097/BOT.0000000000000652
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Intertrochanteric hip fractures are common and costly. Intramedullary fixation has gained popularity as a means of stabilizing intertrochanteric hip fractures. This review article presents some of the controversies surrounding the treatment of intertrochanteric fractures using a cephalomedullary nail. These topics include nail length, the need for distal interlocking, proximal screw design, the number of proximal lag screws, and integrated proximal sliding lag screws.
引用
收藏
页码:635 / 641
页数:7
相关论文
共 50 条
  • [1] Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures
    Baumgaertner, MR
    Curtin, SL
    Lindskog, DM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (348) : 87 - 94
  • [2] Intramedullary fixation of intertrochanteric hip fractures: a comparison of two implant designs
    Nicolas E. Efstathopoulos
    Vassilios S. Nikolaou
    John T. Lazarettos
    International Orthopaedics, 2007, 31 : 71 - 76
  • [3] Intramedullary fixation of intertrochanteric hip fractures: a comparison of two implant designs
    Efstathopoulos, Nicolas E.
    Nikolaou, Vassilios S.
    Lazarettos, John T.
    INTERNATIONAL ORTHOPAEDICS, 2007, 31 (01) : 71 - 76
  • [4] FIXATION IN INTERTROCHANTERIC FRACTURES OF HIP
    FRIEDENBERG, ZB
    GENTCHOS, E
    RUTT, C
    SURGERY GYNECOLOGY AND OBSTETRICS WITH INTERNATIONAL ABSTRACTS OF SURGERY, 1972, 135 (02): : 225 - +
  • [5] Intramedullary fixation of unstable intertrochanteric hip fractures - One or two lag screws
    Kubiak, EN
    Bong, M
    Park, SS
    Kummer, F
    Egol, K
    Koval, KJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (01) : 12 - 17
  • [6] A BIOMECHANICAL EVALUATION OF AN INTRAMEDULLARY FIXATION DEVICE FOR INTERTROCHANTERIC FRACTURES
    FLAHIFF, CM
    NELSON, CL
    GRUENWALD, JM
    HOLLIS, JM
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 35 (01): : 23 - 27
  • [7] The treatment of intertrochanteric fractures with intramedullary hip screw (IMHS)
    Fancellu, G
    Tulic, G
    Ricciardi, A
    Dordolin, P
    Cau, P
    Gulli, S
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S17 - S17
  • [8] Comparison of intramedullary fixation and arthroplasty for the treatment of intertrochanteric hip fractures in the elderly A meta-analysis
    Nie, Boyuan
    Wu, Dou
    Yang, Zhaohui
    Liu, Qiang
    MEDICINE, 2017, 96 (27)
  • [9] ENDER NAIL FIXATION FOR INTERTROCHANTERIC HIP FRACTURES
    TRAFTON, PG
    WESTERN JOURNAL OF MEDICINE, 1979, 130 (01): : 57 - 58