Voltammetric study of vitamin K3 at interdigitated array microelectrodes

被引:0
作者
Liu, ZM [1 ]
Li, J [1 ]
You, TY [1 ]
Yang, XR [1 ]
Wang, EK [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, Natl Analyt Res Ctr Electrochem & Spect, Electroanalyt Chem Lab, Changchun 130022, Jilin, Peoples R China
关键词
voltammetric study; vitamin K-3; interdigitated array microelectrodes; single mode; dual mode;
D O I
10.1002/(SICI)1521-4109(199901)11:1<53::AID-ELAN53>3.0.CO;2-O
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cyclic voltammetry of Vitamin K-3 (V-K3) was measured with Pt disk electrode, platinum interdigitated array (Pt-IDA) and Au-IDA microelectrodes in single and dual modes. The effects of pH, scan rate and collector potential on the current of generator and collector were studied. The collection efficiency of V-K3 at IDA electrodes was measured. The linear ranges for current response as a function of V-K3 concentration were found to he 10 mu M-1 mM (i(g)) and 1 mu M - 1 mM (i(c)) for the generator and collector of the Pt-IDA electrode, respectively. The effects of waiting time, potential difference and pulse electrolysis time in differential pulse voltammetry (DPV) on the peak current of V-K3 were studied to get the optimal condition at 0.1 M Na2HPO4, pH 11.50 and 11.0 for Au-IDA and Pt-IDA, respectively.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 30 条
[1]   THIN-LAYER ELECTROCHEMISTRY - STEADY-STATE METHODS OF STUDYING RATE PROCESSES [J].
ANDERSON, LB ;
REILLEY, CN .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1965, 10 (04) :295-&
[2]   ELECTROCHEMICAL RESPONSE AT MICROARRAY ELECTRODES IN FLOWING STREAMS AND DETERMINATION OF CATECHOLAMINES [J].
AOKI, A ;
MATSUE, T ;
UCHIDA, I .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2206-2210
[3]   QUANTITATIVE-ANALYSIS OF REVERSIBLE DIFFUSION-CONTROLLED CURRENTS OF REDOX SOLUBLE SPECIES AT INTERDIGITATED ARRAY ELECTRODES UNDER STEADY-STATE CONDITIONS [J].
AOKI, K ;
MORITA, M ;
NIWA, O ;
TABEI, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 256 (02) :269-282
[4]   DIGITAL-SIMULATION OF THE MEASURED ELECTROCHEMICAL RESPONSE OF REVERSIBLE REDOX COUPLES AT MICROELECTRODE ARRAYS - CONSEQUENCES ARISING FROM CLOSELY SPACED ULTRAMICROELECTRODES [J].
BARD, AJ ;
CRAYSTON, JA ;
KITTLESEN, GP ;
SHEA, TV ;
WRIGHTON, MS .
ANALYTICAL CHEMISTRY, 1986, 58 (11) :2321-2331
[5]  
BARD AJ, 1980, ELECTROCHEMICAL METH, P183
[6]   FLUORIMETRIC DETERMINATION OF VITAMIN-K3 (MENADIONE SODIUM BISULFITE) IN SYNTHETIC ANIMAL FEED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A POST-COLUMN ZINC REDUCER [J].
BILLEDEAU, SM .
JOURNAL OF CHROMATOGRAPHY, 1989, 472 (02) :371-379
[7]   COMPARISON BETWEEN A DIFFERENTIAL AMPEROMETRIC DETECTOR IN THE REDUCTIVE MODE AND A UV DETECTOR IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH VITAMIN-K3 AS TEST COMPOUND [J].
BRUNT, K ;
BRUINS, CHP ;
DOORNBOS, DA .
ANALYTICA CHIMICA ACTA, 1981, 125 (APR) :85-91
[8]   SIMULATION OF EDGE EFFECTS IN ELECTROANALYTICAL EXPERIMENTS BY ORTHOGONAL COLLOCATION .6. CYCLIC VOLTAMMETRY AT ULTRAMICROELECTRODE ENSEMBLES [J].
CASSIDY, J ;
GHOROGHCHIAN, J ;
SARFARAZI, F ;
SMITH, JJ ;
PONS, S .
ELECTROCHIMICA ACTA, 1986, 31 (06) :629-636
[9]   MICROMETER-SPACED PLATINUM INTERDIGITATED ARRAY ELECTRODE - FABRICATION, THEORY, AND INITIAL USE [J].
CHIDSEY, CE ;
FELDMAN, BJ ;
LUNDGREN, C ;
MURRAY, RW .
ANALYTICAL CHEMISTRY, 1986, 58 (03) :601-607
[10]  
DVHNRIFRTMSN MS, 1988, J CHROMATOGR SCI, V26, P458