Five-year clinical trial using three attachment systems for implant overdentures

被引:55
作者
Cristache, Corina Marilena [1 ,3 ]
Muntianu, Ligia Adriana Stanca [2 ]
Burlibasa, Mihai [3 ]
Didilescu, Andreea Cristiana [4 ,5 ]
机构
[1] Concordia Dent Clin, Bucharest, Romania
[2] Univ Med & Pharm Carol Davila, Fac Med Dent, Bucharest, Romania
[3] Univ Med & Pharm Carol Davila, FMAM, Bucharest, Romania
[4] Dunarea Jos Univ, Fac Med & Pharm, Dept Anat, Galati, Romania
[5] Univ Med & Pharm Carol Davila, Fac Med Dent, Dept Embryol, Bucharest, Romania
关键词
complications; costs; locator; magnet; prosthetic maintenance; retentive anchor; UNSPLINTED ORAL IMPLANTS; MANDIBULAR OVERDENTURES; PROSTHODONTIC MAINTENANCE; PATIENT SATISFACTION; PROSTHETIC OUTCOMES; COMPLETE DENTURES; ITI IMPLANTS; LONG-TERM; PART I; BALL;
D O I
10.1111/clr.12086
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveThe objective is to compare, in a prospective randomized clinical trial, three types of attachment systems for mandibular implant overdenture, focusing on costs, maintenance requirements and complications from baseline to the end of 5-year follow-up period. Materials and MethodsSixty-nine fully mandibular and fully/partially maxillary edentulous patients received two screw-type Straumann implants, in the mandibular canine region. New overdentures with three types of attachment systems were inserted according to an early-loading protocol: Group B (balls, divided into Subgroup B.1 - retentive anchor with gold matrix and Subgroup B.2 - retentive anchor with titanium matrix) (n=23), Group M (magnets) (n=23) and Group L (locator) (n=23). ResultsThe highest maintenance event number (195) was observed in Group B vs. 31 in Group L and 15 in Group M. Significantly more complications were recorded in Subgroup B.1 than in Subgroup B.2, Group M and Group L (P<0.05). Group M registered the highest prosthetic success (82.6%) in the 5years, followed by Group L (78.2%). Subgroup B.1 had the lowest success rate (50%). The magnet group recorded statistically significant higher costs, comparing with the other two groups (P<0.05). ConclusionsThe three attachment systems functioned well after 5years. The magnets had a low maintenance requirement and high success rate, despite the relatively increased initial costs. Retentive anchor with titanium matrix and locator may be a better choice from a financial point of view, taking into consideration the initial low cost of the components and also the reduced number of complications.
引用
收藏
页码:E171 / E178
页数:8
相关论文
共 44 条
[1]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[2]   Mandibular single-implant overdentures: preliminary results of a randomised-control trial on early loading with different implant diameters and attachment systems [J].
Alsabeeha, Nabeel H. M. ;
Payne, Alan G. T. ;
De Silva, Rohana K. ;
Thomson, W. Murray .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (03) :330-337
[3]   The revised CONSORT statement for reporting randomized trials: Explanation and elaboration [J].
Altman, DG ;
Schulz, KF ;
Moher, D ;
Egger, M ;
Davidoff, F ;
Elbourne, D ;
Gotzsche, PC ;
Lang, T .
ANNALS OF INTERNAL MEDICINE, 2001, 134 (08) :663-694
[4]  
Aparicio Carlos, 2003, Clin Implant Dent Relat Res, V5, P57, DOI 10.1111/j.1708-8208.2003.tb00183.x
[5]  
Buser D, 1999, Adv Dent Res, V13, P153
[6]   Complications associated with the ball, bar and Locator attachments for implant-supported overdentures [J].
Cakarer, Sirmahan ;
Can, Taylan ;
Yaltirik, Mehmet ;
Keskin, Cengizhan .
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2011, 16 (07) :C953-C959
[7]  
Cune M, 2010, INT J PROSTHODONT, V23, P310
[8]   Randomization and allocation concealment: a practical guide for researchers [J].
Doig, GS ;
Simpson, F .
JOURNAL OF CRITICAL CARE, 2005, 20 (02) :187-191
[9]  
Feine J S, 2002, Int J Prosthodont, V15, P413
[10]   A long-term follow-up study of non-submerged ITI implants in the treatment of totally edentulous jaws Part I: Ten-year life table analysis of a prospective multicenter study with 1286 implants [J].
Ferrigno, N ;
Laureti, M ;
Fanali, S ;
Grippaudo, G .
CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) :260-273