Long-Term Outcomes of Constrained Liners Cemented into Retained, Well-Fixed Acetabular Components

被引:26
作者
Brown, Timothy S. [1 ]
Tibbo, Meagan E. [1 ]
Arsoy, Diren [1 ]
Lewallen, David G. [1 ]
Hanssen, Arlen D. [1 ]
Trousdale, Robert T. [1 ]
Abdel, Matthew P. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN 55902 USA
关键词
TOTAL HIP-ARTHROPLASTY; LINKED POLYETHYLENE LINER; HIGH-RISK PATIENTS; HIGH FAILURE RATE; REVISION; CEMENTATION; DISLOCATION; SHELL; STRENGTH; IMPLANTS;
D O I
10.2106/JBJS.18.00607
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Cementation of a constrained liner is a viable option for treating instability after total hip arthroplasty (THA) when the acetabular component is well fixed and well aligned. However, concerns regarding long-term mechanical failure and recurrent instability remain. The aim of this study was to evaluate the long-term survivorship, complications, and clinical and radiographic outcomes of constrained polyethylene liners cemented into well-fixed acetabular components at the time of revision THA. Methods: We identified 125 cases in which a constrained liner of 1 design was cemented into a retained, osseointegrated acetabular component during revision THA between 1998 and 2006. The mean patient age at revision was 70 years. Mean follow-up was 7 years. Survivorship data, risk of instability, and clinical and radiographic outcomes were analyzed. Results: Survivorship free from revision for instability was 86% at 5 years and 81% at 10 years. Survivorship free from aseptic acetabular component revision was 78% at 5 years and 65% at 10 years, with the most common failure mechanism being dissociation of the constrained liner from the acetabular component. Survivorship free from revision for any reason was 76% at 5 years and 60% at 10 years. The most common complications were instability and peri prosthetic joint infection, with cumulative incidences at 7 years of 18% and 11%, respectively. Harris hip scores did not significantly improve. Cup position did not affect implant survivorship or risk of dislocation. Conclusions: Cementing a constrained liner into a retained acetabular shell at the time of revision THA has durable longterm results, with 8 in 10 patients free from instability at 10 years. Aseptic acetabular survivorship was worse (65%) at 10 years, primarily due to dissociation of the constrained liner from the acetabular component.
引用
收藏
页码:620 / 627
页数:8
相关论文
共 50 条
[1]   Dislocationm after revision total hip arthroplasty - An analysis of risk factors and treatment options [J].
Alberton, GM ;
High, WA ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) :1788-1792
[2]   A new method of measuring acetabular cup anteversion on simulated radiographs [J].
Bachhal, Vikas ;
Jindal, Nipun ;
Saini, Gaurav ;
Sament, Radheshyam ;
Kumar, Vishal ;
Chouhan, Devendra ;
Dhillon, Mandeep .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) :1813-1818
[3]   Cementing a liner into a stable cementless acetabular shell:: The double-socket technique [J].
Beaulé, PE ;
Ebramzadeh, E ;
LeDuff, M ;
Prasad, R ;
Amstutz, HC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05) :929-934
[4]   Cementation of a polyethylene liner into a metal shell - Factors related to mechanical stability [J].
Bonner, KF ;
Delanois, RE ;
Harbach, G ;
Bushelow, M ;
Mont, MA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (09) :1587-1593
[5]   Do dual-mobility cups cemented into porous tantalum shells reduce the risk of dislocation after revision surgery?: A retrospective cohort study on 184 patients [J].
Bruggemann, Anders ;
Mallmin, Hans ;
Hailer, Nils P. .
ACTA ORTHOPAEDICA, 2018, 89 (02) :156-162
[6]   A constrained liner cemented into a secure cementless acetabular shell [J].
Callaghan, JJ ;
Parvizi, J ;
Novak, CC ;
Bremner, B ;
Shrader, W ;
Lewallen, DG ;
Johnston, RC ;
Goetz, DD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (10) :2206-2211
[7]  
Callaghan JJ, 2009, ORTHOPEDICS, V32
[8]   Cementing Acetabular Liners Into Secure Cementless Shells for Polyethylene Wear Provides Durable Mid-term Fixation [J].
Callaghan, John J. ;
Hennessy, David W. ;
Liu, Steve S. ;
Goetz, Kirsten E. ;
Heiner, Anneliese D. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (11) :3142-3147
[9]   Cementation of a Dual Mobility Construct in Recurrently Dislocating and High Risk Patients Undergoing Revision Total Arthroplasty [J].
Chalmers, Brian P. ;
Ledford, Cameron K. ;
Taunton, Michael J. ;
Sierra, Rafael J. ;
Lewallen, David G. ;
Trousdale, Robert T. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (05) :1501-1506
[10]   High Failure Rate of Modular Exchange With a Specific Design of a Constrained Liner in High-Risk Patients Undergoing Revision Total Hip Arthroplasty [J].
Chalmers, Brian P. ;
Arsoy, Diren ;
Sierra, Rafael J. ;
Lewallen, David G. ;
Trousdale, Robert T. .
JOURNAL OF ARTHROPLASTY, 2016, 31 (09) :1963-1969