Microfabricated Gas Chromatograph for Rapid, Trace-Level Determinations of Gas-Phase, Explosive Marker Compounds

被引:66
作者
Collin, William R. [1 ,2 ]
Serrano, Gustavo [2 ,3 ]
Wright, Lindsay K. [1 ,2 ]
Chang, Hungwei [2 ,3 ]
Nunovero, Nicolas [2 ,3 ]
Zellers, Edward T. [1 ,2 ,3 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Ctr Wireless Integrated MicroSensing & Syst, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Environm Hlth Sci, Ann Arbor, MI 48109 USA
基金
美国国家科学基金会;
关键词
CHEMIRESISTOR ARRAY; INDOOR AIR; VAPOR; TRICHLOROETHYLENE;
D O I
10.1021/ac402961t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A prototype microfabricated gas chromatograph (mu GC) adapted specifically for the rapid determination of selected gas-phase marker compounds of the explosive 2,4,6-trinitrotoluene (TNT) at sub-parts-per-billion (< ppb) concentrations in complex mixtures is described. Si-microfabricated focuser, separation column, and sensor array components are integrated with a high-volume sampler of conventional construction to reduce analysis time and the limit of detection (LOD). The primary markers selected as target analytes were 2,4-dinitrotoluene (2,4-DNT, a persistent impurity of TNT) and 2,3-dimethyl-2,3-dinitrobutane (DMNB, a taggant), along with 2,6-dinitrotoluene (2,6-DNT, a lessprominent TNT impurity), which was also included in numerous tests. Selective preconcentration, on-column focusing, temperature-programmed chromatographic separation, and sensor array detection/recognition facilitated determinations of the primary markers in the presence of 20 (or more) interferences within similar to 2 min under laptop control. Estimated LODs of 2.2, 0.48, and 0.86 ng were achieved for DMNB, 2,6-DNT, and 2,4-DNT, respectively, which correspond to 0.30, 0.067, and 0.12 ppb in each 1-L air sample collected.
引用
收藏
页码:655 / 663
页数:9
相关论文
共 35 条
[1]  
[Anonymous], EPA600177005
[2]   Characterization of Dense Arrays of Chemiresistor Vapor Sensors with Submicrometer Features and Patterned Nanoparticle Interface Layers [J].
Bohrer, Forest I. ;
Covington, Elizabeth ;
Kurdak, Cagliyan ;
Zellers, Edward T. .
ANALYTICAL CHEMISTRY, 2011, 83 (10) :3687-3695
[3]   Facile hyphenation of gas chromatography and a microcantilever array sensor for enhanced selectivity [J].
Chapman, Peter J. ;
Vogt, Frank ;
Dutta, Pampa ;
Datskos, Panos G. ;
Devault, Gerald L. ;
Sepaniak, Michael J. .
ANALYTICAL CHEMISTRY, 2007, 79 (01) :364-370
[4]   Integrated explosive preconcentrator and electrochemical detection system for 2,4,6-trinitrotoluene (TNT) vapor [J].
Cizek, Karel ;
Prior, Chad ;
Thammakhet, Chongdee ;
Galik, Michal ;
Linker, Kevin ;
Tsui, Ray ;
Cagan, Avi ;
Wake, John ;
La Belle, Jeff ;
Wang, Joseph .
ANALYTICA CHIMICA ACTA, 2010, 661 (01) :117-121
[5]   Comparison of fluorescence and QCM technologies: Example of explosives detection with a π-conjugated thin film [J].
Clavaguera, Simon ;
Montmeat, Pierre ;
Parret, Frederic ;
Pasquinet, Eric ;
Lere-Porte, Jean-Pierre ;
Hairault, Lionel .
TALANTA, 2010, 82 (04) :1397-1402
[6]  
Collin W., 2013, P 17 INT C SOL STAT, P2763
[7]  
Ingram R., 2010, P SOC PHOTO-OPT INS, V7664
[8]  
Jenkins T., 9921 CRREL
[9]  
Kim H., 2007, P TRANSDUCERS 2007, P1505, DOI DOI 10.1109/SENSOR.2007.4300430
[10]   Microfabricated Gas Chromatograph for On-Site Determinations of TCE in Indoor Air Arising from Vapor Intrusion. 2. Spatial/Temporal Monitoring [J].
Kim, Sun Kyu ;
Burris, David R. ;
Bryant-Genevier, Jonathan ;
Gorder, Kyle A. ;
Dettenmaier, Erik M. ;
Zellers, Edward T. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (11) :6073-6080