Assessing test-retest reliability of phase contrast MRI for measuring cerebrospinal fluid and cerebral blood flow dynamics

被引:39
作者
Sakhare, Ashwin R. [1 ,2 ]
Barisano, Giuseppe [2 ,3 ]
Pa, Judy [1 ,2 ,3 ]
机构
[1] Univ Southern Calif, Viterbi Sch Engn, Dept Biomed Engn, Los Angeles, CA USA
[2] Univ Southern Calif, Stevens Neuroimaging & Informat Inst, Dept Neurol, Lab Neuro Imaging, Los Angeles, CA USA
[3] Univ Southern Calif, Neurosci Grad Program, Los Angeles, CA USA
基金
美国国家卫生研究院;
关键词
brain; cerebral blood flow dynamics; cerebrospinal fluid flow dynamics; phase-contrast MRI; test-retest reliability; CHIARI-I MALFORMATION; MAGNETIC-RESONANCE; MULTIPLE-SCLEROSIS; WAVE-FORMS; CSF FLOW; VELOCITY; HYDROCEPHALUS; QUANTIFICATION; REPRODUCIBILITY; AQUEDUCT;
D O I
10.1002/mrm.27752
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposePathological states occur when cerebrospinal fluid (CSF) and cerebral blood flow (CBF) dynamics become dysregulated in the brain. Phase-contrast MRI (PC-MRI) is a noninvasive imaging technique that enables quantitative measurements of CSF and CBF flow. While studies have validated PC-MRI as an imaging technique for flow, few studies have evaluated its reliability for CSF and CBF flow parameters commonly associated with neurological disease. The purpose of this study was to evaluate test-retest reliability at the cerebral aqueduct (CA) and C2-C3 area using PC-MRI to assess the feasibility of investigating CSF and CBF flow dynamics. MethodsThis study was performed on 27 cognitively normal young adults (ages 20-35 years). Flow data was acquired on a 3T Siemens Prisma using a 2D cine-PC pulse sequence. Three consecutive flow measurements were acquired at the CA and C2-C3 area. Intraclass correlation coefficient (ICC) and coefficient of variance (CV) were used to evaluate intrarater, inter-rater, and test-retest reliability. ResultsAmong the 26 flow parameters analyzed, 22 had excellent reliability (ICC > 0.80), including measurements of CSF stroke volume, flush peak, and fill peak, and 4 parameters had good reliability (ICC 0.60-0.79). 16 flow parameters had a mean CV 10%, 7 had a CV 15%, and 3 had a CV 30%. All CSF and CBF flow measurements had excellent inter-rater and intrarater reliability (ICC > 0.80). ConclusionThis study shows that CSF and CBF flow can be reliably measured at the CA and C2-C3 area using PC-MRI, making it a promising tool for studying flow dynamics in the central nervous system.
引用
收藏
页码:658 / 670
页数:13
相关论文
共 70 条
[1]   The Effect of Daily Caffeine Use on Cerebral Blood Flow: How Much Caffeine can we Tolerate? [J].
Addicott, Merideth A. ;
Yang, Lucie L. ;
Peiffer, Ann M. ;
Burnett, Luke R. ;
Burdette, Jonathan H. ;
Chen, Michael Y. ;
Hayasaka, Satoru ;
Kraft, Robert A. ;
Maldjian, Joseph A. ;
Laurienti, Paul J. .
HUMAN BRAIN MAPPING, 2009, 30 (10) :3102-3114
[2]   QUANTITATIVE CINE-MODE MAGNETIC-RESONANCE-IMAGING OF CHIARI-I MALFORMATIONS - AN ANALYSIS OF CEREBROSPINAL-FLUID DYNAMICS [J].
ARMONDA, RA ;
CITRIN, CM ;
FOLEY, KT ;
ELLENBOGEN, RG .
NEUROSURGERY, 1994, 35 (02) :214-223
[3]   Glial and neuronal control of brain blood flow [J].
Attwell, David ;
Buchan, Alastair M. ;
Charpak, Serge ;
Lauritzen, Martin ;
MacVicar, Brian A. ;
Newman, Eric A. .
NATURE, 2010, 468 (7321) :232-243
[4]   Relationship between cerebrospinal fluid and blood dynamics in healthy volunteers and patients with communicating hydrocephalus [J].
Balédent, O ;
Gondry-Jouet, C ;
Meyer, ME ;
De Marco, G ;
Le Gars, D ;
Henry-Feugeas, MC ;
Idy-Peretti, I .
INVESTIGATIVE RADIOLOGY, 2004, 39 (01) :45-55
[5]   Cerebrospinal fluid dynamics and relation with blood flow -: A magnetic resonance study with semiautomated cerebrospinal fluid segmentation [J].
Balédent, O ;
Henry-Feugeas, MCC ;
Idy-Peretti, I .
INVESTIGATIVE RADIOLOGY, 2001, 36 (07) :368-377
[6]   Can MR measurement of intracranial hydrodynamics and compliance differentiate which patient with idiopathic normal pressure hydrocephalus will improve following shunt insertion? [J].
Bateman, G. A. ;
Loiselle, A. M. .
ACTA NEUROCHIRURGICA, 2007, 149 (05) :455-462
[7]   Cerebrospinal fluid flow imaging by using phase-contrast MR technique [J].
Battal, B. ;
Kocaoglu, M. ;
Bulakbasi, N. ;
Husmen, G. ;
Sanal, H. Tuba ;
Tayfun, C. .
BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1004) :758-765
[8]   Concomitant gradient terms in phase contrast MR: Analysis and correction [J].
Bernstein, MA ;
Zhou, XHJ ;
Polzin, JA ;
King, KF ;
Ganin, A ;
Pelc, NJ ;
Glover, GH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (02) :300-308
[9]  
BHADELIA RA, 1995, AM J NEURORADIOL, V16, P389
[10]   CEREBROSPINAL-FLUID FLOW WAVE-FORMS - ANALYSIS IN PATIENTS WITH CHIARI-I MALFORMATION BY MEANS OF GATED PHASE-CONTRAST MR-IMAGING VELOCITY-MEASUREMENTS [J].
BHADELIA, RA ;
BOGDAN, AR ;
WOLPERT, SM ;
LEV, S ;
APPIGNANI, BA ;
HEILMAN, CB .
RADIOLOGY, 1995, 196 (01) :195-202