Liquid chromatographic-electrospray ionization mass spectrometric quantitative analysis of buprenorphine, norbuprenorphine, nordiazepam and oxazepam in rat plasma

被引:15
作者
Pirnay, S
Herve, F
Bouchonnet, S
Perrin, B
Baud, FJ
Ricordel, I
机构
[1] NIDA, Chem & Drug Metab Sect, NIH, Baltimore, MD 21224 USA
[2] Lab Toxicol Prefecture Police, F-75012 Paris, France
[3] Univ Paris 07, INSERM, U705, CNRS,UMR 7157, F-75475 Paris, France
[4] Univ Paris 05, Hop Fernand Widal, F-75475 Paris 10, France
[5] Ecole Polytech, Dept Chim Mecanismes Reactionnels, F-91128 Palaiseau, France
关键词
buprenorphine; norbuprenorphine; nordiazepam; oxazepam; LC-ESI-MS; rat plasma; validation;
D O I
10.1016/j.jpba.2006.02.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A liquid chromatographic-mass spectrometric method with electrospray ionization is presented for the simultaneous determination of buprenorphine, nordiazepam and their pharmacologically active metabolites, norbuprenorphine and oxazepam, in rat plasma. The drugs were extracted from plasma by liquid-liquid extraction and chromatographically separated using a gradient elution of aqueous ammonium formate and acetonitrile. Following electrospray ionization, the analytes were quantified in the single ion storage mode. The assay was validated according to current acceptance criteria for bioanalytical method validation. It was proved to be linear from 0.7 to 200 ng/ml plasma for buprenorphine, 1.0 to 200 ng/ml for norbuprenorphine, 2.0 to 200 ng/ml for nordiazepam, and from 5.0 to 200 ng/ml for oxazepam. The average recoveries of buprenorphine, norbuprenorphine, nordiazepam and oxazepam were 89, 39, 88 and 82%, respectively, with average coefficients of variation ranging from 1.8 to 14.3%. The limits of quantitation for these drugs were 0.7, 1.0, 2.0 and 5.0 ng/ml, respectively, with associated precisions within 17% and accuracies within +/- 18% of the nominal values. Both the intra- and inter-assay precision values did not exceed 11.3% for the four analytes. Intra- and inter-assay accuracies lay within +/- 15% of the nominal values. The validated method was applied to the determination of buprenorphine, norbuprenorphine, nordiazepam, and oxazepam in plasma samples collected from rats at various times after intravenous administration of buprenorphine and nordiazepam. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1135 / 1145
页数:11
相关论文
共 42 条
[1]  
BICKEL WK, 1988, J PHARMACOL EXP THER, V247, P47
[2]   Liquid chromatography-mass spectrometry as a routine method in forensic sciences: a proof of maturity [J].
Bogusz, MJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 748 (01) :3-19
[3]   Flunitrazepam variably alters morphine, buprenorphine, and methadone lethality in the rat [J].
Borron, SW ;
Monier, C ;
Risède, P ;
Baud, FJ .
HUMAN & EXPERIMENTAL TOXICOLOGY, 2002, 21 (11) :599-605
[4]   Sensitive determination of buprenorphine and its N-dealkylated metabolite norbuprenorphine in human plasma by liquid chromatography coupled to tandem mass spectrometry [J].
Ceccato, A ;
Klinkenberg, R ;
Hubert, P ;
Streel, B .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) :619-631
[5]  
CONE EJ, 1984, DRUG METAB DISPOS, V12, P577
[6]   BENZODIAZEPINE USE AMONG INJECTING HEROIN USERS [J].
DARKE, SG ;
ROSS, JE ;
HALL, WD .
MEDICAL JOURNAL OF AUSTRALIA, 1995, 162 (12) :645-647
[7]   Flunitrazepam: an evaluation of use, abuse and toxicity [J].
Druid, H ;
Holmgren, P ;
Ahlner, J .
FORENSIC SCIENCE INTERNATIONAL, 2001, 122 (2-3) :136-141
[8]  
Gaulier JM, 2000, J FORENSIC SCI, V45, P226
[9]  
GOPAL S, 2002, EUR J PHARM SCI, V62, P148
[10]   Trends in opiate and opioid poisonings in addicts in north-east Paris and suburbs, 1995-99 [J].
Gueye, PN ;
Megarbane, B ;
Borron, SW ;
Adnet, F ;
Galliot-Guilley, M ;
Ricordel, I ;
Tourneau, J ;
Goldgran-Toledano, D ;
Baud, FJ .
ADDICTION, 2002, 97 (10) :1295-1304