A diamond detector in the dosimetry of high-energy electron and photon beams

被引:73
|
作者
Laub, WU [1 ]
Kaulich, TW [1 ]
Nüsslin, F [1 ]
机构
[1] Univ Tubingen, Dept Med Phys, D-72076 Tubingen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1999年 / 44卷 / 09期
关键词
D O I
10.1088/0031-9155/44/9/306
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A diamond detector type 60003 (PTW Freiburg) was examined for the purpose of dosimetry with 4-20 MeV electron beams and 4-25 MV photon beams. Results were compared with those obtained by using a Markus chamber for electron beams and an ionization chamber for photon beams. Dose distributions were measured in a water phantom with the detector connected to a Unidos electrometer (PTW Freiburg). After a pre-irradiation of about 5 Gy the diamond detector shows a stability in response which is better than that of an ionization chamber. The current of the diamond detector was measured under variation of photon beam dose rate between 0.1 and 7 Gy min(-1). Different FSDs were chosen. Furthermore the pulse repetition frequency and the depth of the detector were changed. The electron beam dose rate was varied between 0.23 and 4.6 Gy min(-1) by changing the pulse-repetition frequency. The response shows no energy dependence within the covered photon-beam energy range. Between 4 MeV and 18 MeV electron beam energy it shows only a small energy dependence of about 2%, as expected from theory. For smaller electron energies the response increases significantly and an influence of the contact material used for the diamond detector can be surmised. A slight sublinearity of the current and dose rare was found. Detector current and dose rate are related by the expression i proportional to (D) over dot(Delta), where i is the detector current, (D) over dot is the dose rate and Delta is a correction factor of approximately 0.963. Depth-dose curves of photon beams, measured with the diamond detector, show a slight overestimation compared with measurements with the ionization chamber. This overestimation is compensated for by the above correction term. The superior spatial resolution of the diamond detector leads to minor deviations between depth-dose curves of electron beams measured with a Markus chamber and a diamond detector.
引用
收藏
页码:2183 / 2192
页数:10
相关论文
共 50 条
  • [1] SWISS RECOMMENDATIONS FOR THE DOSIMETRY OF HIGH-ENERGY PHOTON BEAMS AND ELECTRON-BEAMS
    ANDRE, L
    VONARX, A
    CORD, I
    GARAVAGLIA, G
    JONESCU, F
    VALLEY, JF
    HELVETICA PHYSICA ACTA, 1987, 60 (02): : 262 - 262
  • [2] Diamond detector in absorbed dose measurements in high-energy linear accelerator photon and electron beams
    Ravichandran, Ramamoorthy
    Binukumar, John Pichy
    Al Amri, Iqbal
    Davis, Cheriyathmanjiyil Antony
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 291 - 303
  • [3] SWISS RECOMMENDATIONS FOR THE DOSIMETRY OF HIGH-ENERGY PHOTON AND ELECTRON-BEAMS
    GARAVAGLIA, G
    ANDRE, L
    ARX, AV
    CORDT, I
    IONESCU, F
    VALLEY, JF
    MEDICAL PHYSICS, 1986, 13 (04) : 575 - 575
  • [4] NEW PROTOCOLS FOR THE DOSIMETRY OF HIGH-ENERGY PHOTON AND ELECTRON-BEAMS
    DUTREIX, A
    MIJNHEER, B
    SVENSSON, H
    RADIOTHERAPY AND ONCOLOGY, 1985, 4 (04) : 289 - 290
  • [5] Design and characterization of a tissue-equivalent CVD-diamond detector for clinical dosimetry in high-energy photon beams
    Gorka, B.
    Nilsson, B.
    Svensson, R.
    Brahme, A.
    Ascarelli, P.
    Trucchi, D. M.
    Conte, G.
    Kalish, R.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2008, 24 (03): : 159 - 168
  • [6] Quantification of mean energy and photon contamination for accurate dosimetry of high-energy electron beams
    Sorcini, BB
    Hyodynmaa, S
    Brahme, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (10): : 1849 - 1873
  • [7] Influence of electron contamination on in vivo surface dosimetry for high-energy photon beams
    Sjogren, R
    Karlsson, M
    MEDICAL PHYSICS, 1998, 25 (06) : 916 - 921
  • [9] DOSIMETRY AND QUALITY SPECIFICATION OF HIGH-ENERGY PHOTON BEAMS
    BRAHME, A
    ANDREO, P
    ACTA RADIOLOGICA ONCOLOGY, 1986, 25 (03): : 213 - 223
  • [10] DOSIMETRY OF LARGE WEDGED HIGH-ENERGY PHOTON BEAMS
    PODGORSAK, MB
    KUBSAD, SS
    PALIWAL, BR
    MEDICAL PHYSICS, 1993, 20 (02) : 369 - 373