Using on-line solid phase extraction for flow-injection spectrophotometric determination of salbutamol

被引:36
作者
Satínsky, D [1 ]
Karlícek, R [1 ]
Svoboda, A [1 ]
机构
[1] Charles Univ, Fac Pharm, Dept Analyt Chem, Hradec Kralove 50005, Czech Republic
关键词
flow injection analysis; solid phase extraction; salbutamol;
D O I
10.1016/S0003-2670(01)01586-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the proposed procedure, the determination of salbutamol with Folin-Ciocalteau reagent (FC) using a flow injection analysis technique (FIA) with spectrophotometric detection at 750nm is described. The lab-made FIA system consisted of a peristaltic pump Gilson Minipulse 3 equipped with Tygon tubes, double 6-port external Vici Valco sample injector and S 2000/SAD500 fiber optic spectrophotometer. It was controlled by a PC with use of originally compiled LabVIEW(R)- supported software containing the mathematical library with various statistical functions for off-line data evaluation. Concentration, volume of reagents and flow rate were optimised by a simplex method. The proposed system was used for the direct determination of salbutamol sulphate in the tablets and the human urine without preliminary pre-treatment of the sample. The negative effect of interfering substances (excipients of the tablets and matrix of the urine) is overcome by a solid phase extraction (SPE), when salbutamol is adsorbed on the solid phase in the microcolumn, which is integrated directly into the flow system. Pre-treatment of the sample takes place directly in the flowing stream. The sample throughput without carryover of on-line SPE was 60-80 samples per hour. With the SPE column (Baker-carboxylic acid), salbutamol was determined in the linear range from 1 to 15 mug ml(-1) (R.S.D. = 1.2%), with detection limit (3sigma) 0.1 mug ml(-1) and a frequency of 40-60 samples per hour in the water solutions. The salbutamol was determined in the linear range from 2 to 20 mug ml(-1) (R.S.D. = 1.7%), with detection limit (3sigma) 1 mug ml(-1) and a frequency of 30 samples per hour in the samples of the human urine. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:103 / 109
页数:7
相关论文
共 16 条
[1]   Spectrophotometric determination of salbutamol sulphate using chlorinated quinones in the presence or absence of acetaldehyde [J].
Bakry, RS ;
Razak, OA ;
ElWalily, AFM ;
Belal, SF .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (03) :357-362
[2]   Analytical methodology for enantiomers of salbutamol in human urine for application in doping control [J].
Bergés, R ;
Segura, J ;
de la Torre, X ;
Ventura, R .
JOURNAL OF CHROMATOGRAPHY B, 1999, 723 (1-2) :173-184
[3]  
BHATT KK, 1999, INDIAN DRUGS, V36, P524
[4]  
BURNS DT, 1992, ANAL CHIM ACTA, V260, P65
[5]  
CHOWDARY KPR, 1997, INDIAN DRUGS, V34, P283
[6]   SOLID-PHASE REACTORS IN FLOW-INJECTION ANALYSIS [J].
DECASTRO, MDL .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1992, 11 (04) :149-155
[7]   AN IMPROVED SPECTROPHOTOMETRIC METHOD FOR THE DETERMINATION OF SALBUTAMOL SULFATE WITH 3-METHYLBENZTHIAZOLINONE-2-HYDRAZONE [J].
GEETA, N ;
BAGGI, TR .
MICROCHEMICAL JOURNAL, 1989, 39 (02) :137-144
[8]   Multiresidue analysis of β2-agonists in human and calf urine using multimodal solid-phase extraction and high-performance liquid chromatography with electrochemical detection [J].
Koole, A ;
Bosman, J ;
Franke, JP ;
de Zeeuw, RA .
JOURNAL OF CHROMATOGRAPHY B, 1999, 726 (1-2) :149-156
[9]  
LAINE LM, 1994, J PHARM BIOMED ANAL, V12, P543
[10]  
Loss JR, 2000, BIOMED CHROMATOGR, V14, P1