Mandibular condylar dimensions: Correlation between 3D tomography and dried skull measurements

被引:1
作者
Scariot, Rafaela [1 ]
Gonsar, Briana [2 ]
Gill, Navenett [2 ]
Furquim, Fabio [1 ]
Cotait de Lucas Corso, Paola Fernanda [1 ]
Trevillato, Paula Cristina [3 ]
Potluri, Anitha [4 ]
Vieira, Alexandre Rezende [2 ]
机构
[1] Positivo Univ, Dept Maxillofacial Surg, Curitiba, PR, Brazil
[2] Univ Pittsburgh, Dept Oral Biol, Pittsburgh, PA USA
[3] Pontificia Univ Catolica Parana, Sch Life Sci, Curitiba, PR, Brazil
[4] Univ Pittsburgh, Dept Diagnost Sci, Pittsburgh, PA USA
来源
CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE | 2019年 / 37卷 / 03期
关键词
Mandibular condyle; skull; cone-beam computed tomography; temporomandibular joint; dimensional measurement accuracy; three-dimensional imaging; mandible; anatomy; TEMPOROMANDIBULAR-JOINT; ACCURACY;
D O I
10.1080/08869634.2017.1409169
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective Compare the anatomical dimensions of mandibular condyles with the same CBCT measurements. Methods Four landmarks were identified on the condyles of dried skulls and are measured with their corresponding areas in CBCT images: Right Width of Condyle (RW), Left Width of Condyle (LW), Right Length of Condyle (RL), and Left Length of Condyle (LL). Results With respect to direct measurements on the dry skulls, statistically significant differences were found between sexes (p < 0.001). When the real values were compared with the CBCT, it was observed that the bias depends on the magnitude of the measurement. It means that there is an underestimation for smaller values and an overestimation for larger values. Conclusion CBCT is reliable imaging modality, but when compared real measures of condyle length are more reliable then width.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 13 条
[1]   Imaging of the temporomandibular joint - A position paper of the American Academy of Oral and Maxillofacial Radiology [J].
Brooks, SL ;
Brand, JW ;
Gibbs, SJ ;
Hollender, L ;
Lurie, AG ;
Omnell, KA ;
Westesson, PL ;
White, SC .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1997, 83 (05) :609-618
[2]   Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography [J].
Hilgers, ML ;
Scarfe, WC ;
Scheetz, JP ;
Farman, AG .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (06) :803-811
[3]   INTERNAL DERANGEMENTS OF THE TEMPOROMANDIBULAR-JOINT - DIAGNOSIS BY DIRECT SAGITTAL COMPUTED-TOMOGRAPHY [J].
MANZIONE, JV ;
KATZBERG, RW ;
BRODSKY, GL ;
SELTZER, SE ;
MELLINS, HZ .
RADIOLOGY, 1984, 150 (01) :111-115
[4]   Geometric accuracy of a newly developed cone-beam device for maxillofacial imaging [J].
Mischkowski, Robert A. ;
Pulsfort, Reinhard ;
Ritter, Lutz ;
Neugebauer, Joerg ;
Brochhagen, Hans Georg ;
Keeve, Erwin ;
Zoeller, Joachim E. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 104 (04) :551-559
[5]   Position and course of the mandibular canal in skulls [J].
Ozturk, Ayla ;
Potluri, Anitha ;
Vieira, Alexandre R. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 113 (04) :453-458
[6]  
Rodrigues AF, 2009, AM J ORTHOD DENTOFAC, V136, P191
[7]  
Rose EK, 2008, ORAL HLTH PREV DENT, V6, P23
[8]   THE TEMPOROMANDIBULAR-JOINT IN YOUNG-ADULTS AT AUTOPSY - A MORPHOLOGIC CLASSIFICATION AND EVALUATION [J].
SOLBERG, WK ;
HANSSON, TL ;
NORDSTROM, B .
JOURNAL OF ORAL REHABILITATION, 1985, 12 (04) :303-321
[9]   Radiographic examination of the temporomandibular joint using cone beam computed tomography [J].
Tsiklakis, K ;
Syriopoulos, K ;
Stamatakis, H .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (03) :196-201
[10]  
WAITZMAN AA, 1992, CLEFT PALATE-CRAN J, V29, P112, DOI 10.1597/1545-1569(1992)029<0112:CSMBOC>2.3.CO