Characterization of a Novel Hafnium-Based X-ray Contrast Agent

被引:19
作者
Frenzel, Thomas [1 ]
Bauser, Marcus [1 ]
Berger, Markus [1 ]
Hilger, Christoph Stephan [1 ]
Hegele-Hartung, Christa [1 ]
Jost, Gregor [1 ]
Neis, Christian [2 ]
Hegetschweiler, Kaspar [2 ]
Riefke, Bjoern [1 ]
Suelzle, Detlev [1 ]
Pietsch, Hubertus [1 ]
机构
[1] Bayer Pharma AG, Drug Discovery, Muellerstr 178, D-13342 Berlin, Germany
[2] Univ Saarland, Inorgan Chem, Saarbrucken, Germany
关键词
CT imaging; hafnium; noniodine contrast agent; radiation dose; pharmacokinetics; toxicology; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; CT; GADOBUTROL; MEDIA;
D O I
10.1097/RLI.0000000000000291
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Characterization of BAY-576, a new x-ray contrast agent which is not based on iodine, but rather on the heavy metal hafnium. Compared with iodine, hafnium provides better x-ray absorption in the energy range of computed tomography (CT) and allows images of comparable quality to be acquired at a significantly reduced radiation dose. Materials and Methods: A range of standard methods were used to explore the physicochemistry of BAY-576 as well as its tolerability in in vitro assays, its pharmacokinetics and toxicology in rats, and its performance in CT imaging in rabbits. Results: BAY-576 is an extraordinarily stable chelate with a metal content of 42% (wt/wt) and with excellent water solubility. Formulations of 300 mg Hf/mL exhibited viscosity (3.3-3.6 mPa) and osmolality (860-985 mOsm/kg) in the range of nonionic x-ray agents. No relevant effects on erythrocytes, the coagulation, or complement system or on a panel of 87 potential biological targets were observed. The compound did not bind to plasma proteins of a number of species investigated. After intravenous injection in rats, it was excreted fast and mainly via the kidneys. Its pharmacokinetics was comparable to known extracellular contrast agents. A dose of 6000 mg Hf/kg, approximately 10 to 20 times the expected diagnostic dose, was well tolerated by rats with only moderate adverse effects. Computed tomography imaging in rabbits bearing a tumor in the liver demonstrated excellent image quality when compared with iopromide at the same contrast agent dose in angiography during the arterial phase. At 70% of the radiation dose, BAY-576 provided a contrast-to-noise ratio of the tumor, which was equivalent to iopromide at 100% radiation dose. Conclusions: The profile of BAY-576 indicates its potential as the first compound in a new class of noniodine x-ray contrast agents, which can contribute to the reduction of the radiation burden in contrast-enhanced CT imaging.
引用
收藏
页码:776 / 785
页数:10
相关论文
共 35 条
[1]  
American College of Radiology, 2011, ACR PRACT GUID PERF
[2]  
Berger M, 2014, Patent, Patent No. [WO2014/173857/A1, 2014173857]
[3]   Radiation Exposure from CT Scans: How to Close Our Knowledge Gaps, Monitor and Safeguard Exposure-Proceedings and Recommendations of the Radiation Dose Summit, Sponsored by NIBIB, February 24-25, 2011 [J].
Boone, John M. ;
Hendee, William R. ;
McNitt-Gray, Michael F. ;
Seltzer, Steven E. .
RADIOLOGY, 2012, 265 (02) :544-554
[4]   Reducing safety-related drug attrition: the use of in vitro pharmacological profiling [J].
Bowes, Joanne ;
Brown, Andrew J. ;
Hamon, Jacques ;
Jarolimek, Wolfgang ;
Sridhar, Arun ;
Waldron, Gareth ;
Whitebread, Steven .
NATURE REVIEWS DRUG DISCOVERY, 2012, 11 (12) :909-922
[5]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[6]  
Dawson P., 1999, Textbook of Contrast Media, V1st
[7]  
Emsley J., 1989, ELEMENTS
[8]   Computed tomography practice Germany - Results of a national survey in 1999 - Preface [J].
Galanski, M ;
Nagel, HD ;
Stamm, G .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (10) :R1-R1
[9]   TOXICOLOGIC AND PHARMACOLOGIC EFFECTS OF HAFNIUM SALTS [J].
HALEY, TJ ;
UPHAM, HC ;
RAYMOND, K ;
KOMESU, N .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1962, 4 (02) :238-&
[10]   A rigid, cyclohexane-based polyamino-polyalcohol as a versatile building block for tailored chelating agents [J].
Hegetschweiler, K .
CHEMICAL SOCIETY REVIEWS, 1999, 28 (04) :239-249