Performance of a high-sensitivity dedicated cardiac SPECT scanner for striatal uptake quantification in the brain based on analysis of projection data

被引:8
作者
Park, Mi-Ae [1 ,2 ]
Moore, Stephen C. [1 ,2 ]
Mueller, Stefan P. [3 ]
McQuaid, Sarah J. [1 ,2 ]
Kijewski, Marie Foley [1 ,2 ]
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
[3] Univ Klinikum Essen, Abt Nukl Med, D-45147 Essen, Germany
关键词
quantitative SPECT; collimation; phantom study; Cramer-Rao bound; striatal imaging; DOPAMINE TRANSPORTERS; PARKINSONS-DISEASE; RECEPTOR;
D O I
10.1118/1.4794488
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkinson disease (PD), as well as for monitoring progression of the disease. Realizing the full potential of DaTscan requires efficient estimation of striatal uptake from SPECT images. They have evaluated two SPECT systems, a conventional dual-head gamma camera with low-energy high-resolution collimators (conventional) and a dedicated high-sensitivity multidetector cardiac imaging system (dedicated) for imaging tasks related to PD. Methods: Cramer-Rao bounds (CRB) on precision of estimates of striatal and background activity concentrations were calculated from high-count, separate acquisitions of the compartments (right striata, left striata, background) of a striatal phantom. CRB on striatal and background activity concentration were calculated from essentially noise-free projection datasets, synthesized by scaling and summing the compartment projection datasets, for a range of total detected counts. They also calculated variances of estimates of specific-to-nonspecific binding ratios (BR) and asymmetry indices from these values using propagation of error analysis, as well as the precision of measuring changes in BR on the order of the average annual decline in early PD. Results: Under typical clinical conditions, the conventional camera detected 2 M counts while the dedicated camera detected 12 M counts. Assuming a normal BR of 5, the standard deviation of BR estimates was 0.042 and 0.021 for the conventional and dedicated system, respectively. For an 8% decrease to BR = 4.6, the signal-to-noise ratio were 6.8 (conventional) and 13.3 (dedicated); for a 5% decrease, they were 4.2 (conventional) and 8.3 (dedicated). Conclusions: This implies that PD can be detected earlier with the dedicated system than with the conventional system; therefore, earlier identification of PD progression should be possible with the high-sensitivity dedicated SPECT camera. (C) 2013 American Association of Physicists in Medicine. [http ://dx.doi. org/10.1118/1.4794488]
引用
收藏
页数:8
相关论文
共 25 条
  • [1] Asenbaum S, 1997, J NUCL MED, V38, P1
  • [2] [I-123]FP-CIT SPECT shows a pronounced decline of striatal dopamine transporter labelling in early and advanced Parkinson's disease
    Booij, J
    Tissingh, G
    Boer, GJ
    Speelman, JD
    Stoof, JC
    Janssen, AGM
    Wolters, EC
    vanRoyen, EA
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1997, 62 (02) : 133 - 140
  • [3] Monitoring therapeutic effects in Parkinson's disease by serial imaging of the nigrostriatal dopaminergic pathway
    Booij, Jan
    Berendse, Henk W.
    [J]. JOURNAL OF THE NEUROLOGICAL SCIENCES, 2011, 310 (1-2) : 40 - 43
  • [4] Imaging Approaches to Parkinson Disease
    Brooks, David J.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (04) : 596 - 609
  • [5] Erlandsson K, 2011, IEEE NUCL SCI CONF R, P3354, DOI 10.1109/NSSMIC.2011.6152608
  • [6] Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology
    Erlandsson, Kjell
    Kacperski, Krzysztof
    van Gramberg, Dean
    Hutton, Brian F.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) : 2635 - 2649
  • [7] Fischman AJ, 1998, SYNAPSE, V29, P128, DOI 10.1002/(SICI)1098-2396(199806)29:2<128::AID-SYN4>3.0.CO
  • [8] 2-9
  • [9] A Novel High-Sensitivity Rapid-Acquisition Single-Photon Cardiac Imaging Camera
    Gambhir, Sanjiv S.
    Berman, Daniel S.
    Ziffer, Jack
    Nagler, Michael
    Sandler, Martin
    Patton, Jim
    Hutton, Brian
    Sharir, Tali
    Ben Haim, Shlomo
    Ben Haim, Simona
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (04) : 635 - 643
  • [10] Genna S., 2004, FUNDAMENTALS PET SPE, P167