Influence of Composite Electrolyte Membrane for Proton Exchange Membrane Fuel Cells

被引:3
作者
Handayani, S. [1 ]
Dewi, E. L. [2 ]
Hardy, J. [1 ]
Christiani, L. [2 ]
Kurniawan [2 ]
机构
[1] Inst Technol Indonesia, Dept Chem Engn, Jl Raya Puspiptek Serpon, Tangerang, Indonesia
[2] Agcy Assessment & Applicat Technol, Ctr Mat Technol, BPPT, Jakarta 810340, Indonesia
来源
INTERNATIONAL CONFERENCE ON INNOVATION IN POLYMER SCIENCE AND TECHNOLOGY | 2012年 / 4卷
关键词
Composite membrane; polyether-ether ketone; acrylonitrile butadiene styrene; silica; proton exchange membrane fuel cell; POLY(ETHER ETHER KETONE); POLYMER MEMBRANES; PERFORMANCE; POLYSULFONE; BLENDS;
D O I
10.1016/j.proche.2012.06.018
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The operation of proton exchange membrane fuel cell (PEMFC) under humidified condition using composite sulfonated polyether-ether ketones (sPEEK) membrane 1 is reported. Composite sPEEK membrane that were used in this report, have been produced and compared by additional of i.e. organic polymer (Acrylonitrile Butadiene Styrene) 2 and silica powder inorganic 3 to sPEEK polymer 1. Whereas, sPEEK 1, which is known as hydrocarbon polyelectrolyte membrane for PEMFC and direct methanol fuel cell (DMFC) to replace Nafion, has been the most used in both PEMFC and DMFC due to its good performance even though in low humidified condition it showed poor current density. Here we reported the effect of inorganic silica in hydrocarbon sPEEK membrane that contributes for a better water management system inside the cell, and showed 0.16 W/cm(2) of power density which is 78% higher than that of non-silica modified. (C) 2012 Published by Elsevier Ltd.
引用
收藏
页码:123 / 130
页数:8
相关论文
共 25 条
[1]   Polymeric proton conducting membranes for medium temperature fuel cells (110-160°C) [J].
Alberti, G ;
Casciola, M ;
Massinelli, L ;
Bauer, B .
JOURNAL OF MEMBRANE SCIENCE, 2001, 185 (01) :73-81
[2]  
Anis N., 2009, INT C FUEL CELL HYDR
[3]  
[Anonymous], INDONESIAN J MAT SCI
[4]   Influence of the acid-base characteristics of inorganic fillers on the high temperature performance of composite membranes in direct methanol fuel cells [J].
Aricò, AS ;
Baglio, V ;
Di Blasi, A ;
Creti, P ;
Antonucci, PL ;
Antonucci, V .
SOLID STATE IONICS, 2003, 161 (3-4) :251-265
[5]   Sulphonated poly(ether ether ketone) membranes for fuel cell application: Thermal and structural characterisation [J].
Carbone, A. ;
Pedicini, R. ;
Portale, G. ;
Longo, A. ;
D'Ilario, L. ;
Passalacqua, E. .
JOURNAL OF POWER SOURCES, 2006, 163 (01) :18-26
[6]   A performance and degradation study of Nafion 212 membrane for proton exchange membrane fuel cells [J].
Fernandes, Adriano C. ;
Ticianelli, Edson Antonio .
JOURNAL OF POWER SOURCES, 2009, 193 (02) :547-554
[7]   Ionomeric membranes for proton exchange membrane fuel cell (PEMFC): sulfonated polysulfone associated with phosphatoantimonic acid [J].
Genova-Dimitrova, P ;
Baradie, B ;
Foscallo, D ;
Poinsignon, C ;
Sanchez, JY .
JOURNAL OF MEMBRANE SCIENCE, 2001, 185 (01) :59-71
[8]   A Proton-Conducting Polymer Membrane as Solid Electrolyte - Function and Required Properties [J].
Gubler, Lorenz ;
Scherer, Guenther G. .
FUEL CELLS I, 2008, 215 (01) :1-14
[9]  
Handayani S., 2008, P INT SEM CHEM 2008, VOP028, P152
[10]  
Handayani S., 2007, JURNAL TEKNOLOGI, V2, P85