Two-year clinical, angiographic, and serial optical coherence tomographic follow-up after implantation of an everolimus-eluting bioresorbable scaffold and an everolimus-eluting metallic stent: insights from the randomised ABSORB Japan trial

被引:123
作者
Onuma, Yoshinobu [1 ]
Sotomi, Yohei [2 ]
Shiomi, Hiroki [3 ]
Ozaki, Yukio [4 ]
Namiki, Atsuro [5 ]
Yasuda, Satoshi [6 ]
Ueno, Takafumi [7 ]
Ando, Kenji [8 ]
Furuya, Jungo [9 ]
Igarashi, Keiichi [9 ]
Kozuma, Ken [10 ]
Tanabe, Kengo [11 ]
Kusano, Hajime [12 ]
Rapoza, Richard [12 ]
Popma, Jeffrey J. [13 ]
Stone, Gregg W. [14 ,15 ]
Simonton, Charles [12 ]
Serruys, Patrick W. [16 ]
Kimura, Takeshi [3 ]
机构
[1] Erasmus MC, Thoraxctr, Rotterdam, Netherlands
[2] Acad Med Ctr, Amsterdam, Netherlands
[3] Kyoto Univ Hosp, Kyoto, Japan
[4] Fujita Hlth Univ Hosp, Dept Cardiol, Toyoake, Aichi, Japan
[5] Kanto Rosai Hosp, Dept Cardiol, Kawasaki, Kanagawa, Japan
[6] Natl Cerebral & Cardiovasc Ctr, Dept Cardiovasc Med, Osaka, Japan
[7] Kurume Univ, Sch Med, Dept Med, Div Cardiovasc Med, Kurume, Fukuoka, Japan
[8] Kokura Mem Hosp, Div Cardiol, Kitakyushu, Fukuoka, Japan
[9] Japan Community Hlth Care Org Hokkaido Hosp, Cardiovasc Ctr, Sapporo, Hokkaido, Japan
[10] Teikyo Univ Hosp, Tokyo, Japan
[11] Mitsui Mem Hosp, Tokyo, Japan
[12] Abbott Vasc, Santa Clara, CA USA
[13] Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[14] Columbia Univ, Med Ctr, New York Presbyterian Hosp, New York, NY USA
[15] Cardiovasc Res Fdn, New York, NY USA
[16] Imperial Coll London, NHLI, Int Ctr Circulatory Hlth, London, England
关键词
everolimus-eluting bioresorbable scaffold; everolimus-eluting metallic stent; optical coherence tomography; randomised trial; CORONARY-ARTERY-DISEASE; VASCULAR SCAFFOLD; PATIENT-LEVEL; THROMBOSIS; 2ND-GENERATION; OUTCOMES;
D O I
10.4244/EIJY16M09_01
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: We sought to investigate two-year clinical and serial optical coherence tomography (OCT) outcomes after implantation of a fully bioresorbable vascular scaffold (BVS) or a cobalt-chromium everolimus-eluting stent (CoCr-EES). Methods and results: In the ABSORB Japan trial, 400 patients were randomised in a 2:1 ratio to BVS (N=266) or CoCr-EES (N=134). A pre-specified OCT subgroup (N=125, OCT-1 group) underwent angiography and OCT post procedure and at two years. Overall, the two-year TLF rates were 7.3% and 3.8% in the BVS and CoCr-EES arms (p=0.18), respectively. Very late scaffold thrombosis (VLST) beyond one year was observed in 1.6% (four cases: all in non-OCT-1 subgroups) of the BVS arm, while there was no VLST in the CoCr-EES arm. In three cases, OCT at the time of or shortly after VLST demonstrated strut discontinuities, malapposition and/or uncovered struts. However, the vessel healing by two-year OCT was nearly complete in both BVS and CoCr-EES arms with almost fully covered struts, and minimal malapposition. The flow area by two-year OCT was smaller in the BVS arm than in the CoCr-EES arm, mainly due to tissue growth inside the device. However, there were no differences between the BVS and CoCr-EES with regard to the quality of homogenous tissues growing inside the devices. Conclusions: The rate of TLF was numerically higher in the BVS arm than in the CoCr-EES arm, although this difference was not statistically significant. VLST was observed only in the BVS arm at a rate of 1.6% between one and two years. Further studies are mandatory to investigate the risk of BVS relative to metallic stents for VLST, and the underlying mechanisms of BVS VLST.
引用
收藏
页码:1090 / 1101
页数:12
相关论文
共 29 条
  • [1] [Anonymous], CIRC CARDIOVASC INTE
  • [2] Vascular Compliance Changes of the Coronary Vessel Wall After Bioresorbable Vascular Scaffold Implantation in the Treated and Adjacent Segments
    Brugaletta, Salvatore
    Gogas, Bill D.
    Garcia-Garcia, Hector M.
    Farooq, Vasim
    Girasis, Chrysafios
    Heo, Jung Ho
    van Geuns, Robert Jan
    de Bruyne, Bernard
    Dudek, Dariuz
    Koolen, Jacques
    Smits, Pieter
    Veldhof, Susan
    Rapoza, Richard
    Onuma, Yoshinobu
    Ormiston, John
    Serruys, Patrick W.
    [J]. CIRCULATION JOURNAL, 2012, 76 (07) : 1616 - 1623
  • [3] Chevalier B, 2016, EUROINTERVENTION
  • [4] Intravascular ultrasound-guided optimized stent deployment - Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)
    de Jaegere, P
    Mudra, H
    Figulla, H
    Almagor, Y
    Doucet, S
    Penn, I
    Colombo, A
    Hamm, C
    Bartorelli, A
    Rothman, M
    Nobuyoshi, M
    Yamaguchi, T
    Voudris, V
    DiMario, C
    Makovski, S
    Hausmann, D
    Rowe, S
    Rabinovich, S
    Sunamura, M
    van Es, GA
    [J]. EUROPEAN HEART JOURNAL, 1998, 19 (08) : 1214 - 1223
  • [5] Thrombosis of Second-Generation Drug-Eluting Stents in Real Practice Results From the Multicenter Spanish Registry ESTROFA-2 (Estudio Espanol Sobre Trombosis de Stents Farmacoactivos de Segunda Generacion-2)
    de la Torre Hernandez, Jose M.
    Alfonso, Fernando
    Gimeno, Federico
    Diarte, Jose A.
    Lopez-Palop, Ramon
    Perez de Prado, Armando
    Rivero, Fernando
    Sanchis, Juan
    Larman, Mariano
    Diaz, Jose F.
    Elizaga, Jaime
    Martin Moreiras, Javier
    Gomez Jaume, Alfredo
    Hernandez, Jose M.
    Mauri, Josepa
    Sanchez Recalde, Angel
    Bullones, Juan A.
    Rumoroso, Jose R.
    Garcia del Blanco, Bruno
    Baz, Jose A.
    Bosa, Francisco
    Botas, Javier
    Hernandez, Felipe
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (09) : 911 - 919
  • [6] Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease
    Ellis, Stephen G.
    Kereiakes, Dean J.
    Metzger, D. Christopher
    Caputo, Ronald P.
    Rizik, David G.
    Teirstein, Paul S.
    Litt, Marc R.
    Kini, Annapoorna
    Kabour, Ameer
    Marx, Steven O.
    Popma, Jeffrey J.
    McGreevy, Robert
    Zhang, Zhen
    Simonton, Charles
    Stone, Gregg W.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2015, 373 (20) : 1905 - 1915
  • [7] Bioresorbable Vascular Scaffolds Versus Metallic Stents in Patients With Coronary Artery Disease ABSORB China Trial
    Gao, Runlin
    Yang, Yuejin
    Han, Yaling
    Huo, Yong
    Chen, Jiyan
    Yu, Bo
    Su, Xi
    Li, Lang
    Kuo, Hai-Chien
    Ying, Shih-Wa
    Cheong, Wai-Fung
    Zhang, Yunlong
    Su, Xiaolu
    Xu, Bo
    Popma, Jeffery J.
    Stone, Gregg W.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (21) : 2298 - 2309
  • [8] Head-to-Head Comparison of the Neointimal Response Between Metallic and Bioresorbable Everolimus-Eluting Scaffolds Using Optical Coherence Tomography
    Gomez-Lara, Josep
    Brugaletta, Salvatore
    Farooq, Vasim
    Onuma, Yoshinobu
    Diletti, Roberto
    Windecker, Stephan
    Thuesen, Leif
    McClean, Dougal
    Koolen, Jacques
    Whitbourn, Robert
    Dudek, Dariusz
    Smits, Pieter C.
    Chevalier, Bernard
    Regar, Evelyn
    Veldhof, Susan
    Rapoza, Richard
    Ormiston, John A.
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (12) : 1271 - 1280
  • [9] Vascular Tissue Reaction to Acute Malapposition in Human Coronary Arteries Sequential Assessment With Optical Coherence Tomography
    Gutierrez-Chico, Juan Luis
    Wykrzykowska, Joanna
    Nueesch, Eveline
    van Geuns, Robert Jan
    Koch, Karel T.
    Koolen, Jacques J.
    di Mario, Carlo
    Windecker, Stephan
    van Es, Gerrit-Anne
    Gobbens, Pierre
    Jueni, Peter
    Regar, Evelyn
    Serruys, Patrick W.
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (01) : 20 - U81
  • [10] Iannaccone M, 2016, EUR HEART J CARDIOVA