A pixel is an artifact: On the necessity of zero-filling in fourier imaging

被引:18
作者
Zhu, Xiaolu [1 ]
Tomanek, Boguslaw [2 ]
Sharp, Jonathan [1 ]
机构
[1] Natl Res Council Canada, Calgary, AB, Canada
[2] Natl Res Council Canada, MR Technol Grp, Calgary, AB, Canada
关键词
MRI; Fourier transform; zero-filling; image interpolation; k-space; ZOOMED MR IMAGES; FILLED INTERPOLATION; ANGIOGRAPHY;
D O I
10.1002/cmr.a.21256
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
MR imaging data is sometimes presented in a patchwork quilt format with individual pixels visible as squares of uniform intensity. This phenomenon often arises by default from an image space convolution (performed implicitly by the graphics system) used to convert the sparse point sampling of the spatial domain offered by the discrete Fourier transform (DFT) into a sufficiently dense sampling to allow assignment of an intensity value to each addressable point on the display device. Typical examples are fMRI maps, spectroscopic images and zoomed-in views. These square patches are image structure not present in the object, i.e., artifacts. This form of image display is studied by both an image analysis method and by Fourier analysis. Image formation by display of the 2D DFT of an acquired k-space matrix as a 2D pixel array is a poor reconstruction because it does not ensure a faithful representation of the spatial frequency content actually present in the data. By analysis of the visual appearance of 2D pixel arrays we show that there are two principal effects: (a) attenuation of higher spatial frequencies (i.e., low-pass filtering); (b) introduction of artifactual high frequency image structure. These effects can lead to very poor performance with an artifact/signal ratio of over 200% in the corners of 2D k-space. Generated k-space maps demonstrate that both detrimental effects increase radially in k-space. The simple remedy is to zero-fill (resulting in image interpolation) until individual pixels become invisible in the displayed image. Alternatively, data modeling may be used. (c) 2013 Wiley Periodicals, Inc. Concepts Magn Reson Part 42A: 3244, 2013.
引用
收藏
页码:32 / 44
页数:13
相关论文
共 18 条
[1]  
[Anonymous], 2010, MAGN RESON MED, V63
[2]   FOURIER SPECTROSCOPY AND CAUSALITY PRINCIPLE [J].
BARTHOLD.E ;
ERNST, RR .
JOURNAL OF MAGNETIC RESONANCE, 1973, 11 (01) :9-19
[3]   Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy [J].
Bernstein, MA ;
Fain, SB ;
Riederer, SJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :270-280
[4]  
Brigham E. O., 1988, FAST FOURIER TRANSFO
[5]   A high quality 2x image interpolator [J].
Carrato, S ;
Tenze, L .
IEEE SIGNAL PROCESSING LETTERS, 2000, 7 (06) :132-134
[6]   HIGH-QUALITY ZOOMED MR IMAGES [J].
CONSTABLE, RT ;
KAY, I ;
SMITH, MR ;
HENKELMAN, RM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (01) :179-181
[7]   REDUCTION OF PARTIAL-VOLUME ARTIFACTS WITH ZERO-FILLED INTERPOLATION IN 3-DIMENSIONAL MR-ANGIOGRAPHY [J].
DU, YPP ;
PARKER, DL ;
DAVIS, WL ;
CAO, G .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) :733-741
[8]   Improved image registration by using Fourier interpolation [J].
Eddy, WF ;
Fitzgerald, M ;
Noll, DC .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :923-931
[9]   Improved depiction of small anatomic structures in MR images using Gaussian-weighted spirals and zero-filled interpolation [J].
Elgavish, RA ;
Twieg, DB .
MAGNETIC RESONANCE IMAGING, 2003, 21 (02) :103-112
[10]   Variability of myocardial perfusion dark rim Gibbs artifacts due to sub-pixel shifts [J].
Ferreira, Pedro ;
Gatehouse, Peter ;
Kellman, Peter ;
Bucciarelli-Ducci, Chiara ;
Firmin, David .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2009, 11