PLA/F68/Dexamethasone implants prepared by hot-melt extrusion for controlled release of anti-inflammatory drug to implantable medical devices: I. Preparation, characterization and hydrolytic degradation study

被引:54
作者
Li, DeXia [1 ,2 ]
Guo, Gang [1 ,2 ]
Fan, RangRang [1 ,2 ]
Liang, Jian [3 ]
Deng, Xin [3 ]
Luo, Feng [1 ,2 ]
Qian, ZhiYong [1 ,2 ]
机构
[1] Sichuan Univ, W China Med Sch, W China Hosp, State Key Lab Biotherapy, Chengdu 610041, Peoples R China
[2] Sichuan Univ, W China Med Sch, W China Hosp, Ctr Canc, Chengdu 610041, Peoples R China
[3] Guangxi Tradit Chinese Med Univ, RuiKang Hosp, Nanning 530011, Peoples R China
基金
对外科技合作项目(国际科技项目); 中国国家自然科学基金;
关键词
PLA; PEG-PPG-PEG; Dexamethasone; Hot-melt extrusion; Controlled drug delivery; In vitro study; Biocompatibility; SUSTAINED-RELEASE; MATRIX TABLETS; DEXAMETHASONE; DELIVERY; COMPRESSION; COPOLYMERS; BIOSENSORS; PELLETS; SYSTEM; FILMS;
D O I
10.1016/j.ijpharm.2012.11.019
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Dexamethasone (Dex)-loaded implants were prepared by poly(D,L-lactic acid) (PLA) and poly(ethylene glycol)-block-poly(propylene glycol)-block-poly(ethylene glycol) copolymer (PEG-PPG-PEG, Pluronic F68) using hot-melt extrusion method. The purpose of this research was to develop a hot-melt extruded implant PLA/F68/Dex for controlling release of Dex at the implant site. Drug loading and encapsulation efficiency were determined by UV spectrophotometer analysis. The maximum value of the drug loading and encapsulation efficiency for the implants was up to 48.9% and 97.9%, respectively. Differential scanning calorimetry was used to evaluate stability and interaction between the implant and drug. We had studied the water uptake of PLA/F68 implants kept constant at about 12% due to the water was absorbed to a large extent. Dex release profile in vitro was studied, and the results showed that the maximum value of the release rate was approximately 20%. The degradation behavior was confirmed by mass loss and scanning electron microscopy. In addition, the in vivo biocompatibility study indicated that the implants had no negative influence as a foreign material in the body response. (C) 2012 Elsevier B. V. All rights reserved.
引用
收藏
页码:365 / 372
页数:8
相关论文
共 36 条
[1]   Hot melt extrusion of acrylic films [J].
AitkenNichol, C ;
Zhang, F ;
McGinity, JW .
PHARMACEUTICAL RESEARCH, 1996, 13 (05) :804-808
[2]  
Bhardwaj Upkar, 2007, J Diabetes Sci Technol, V1, P8
[3]  
Bhardwaja U., 2010, INT J PHARMACEUT, V384, P78
[4]   Properties of hot-melt extruded tablet formulations for the colonic delivery of 5-aminosalicylic acid [J].
Bruce, LD ;
Shah, NH ;
Malick, AW ;
Infeld, MH ;
McGinity, JW .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2005, 59 (01) :85-97
[5]   Site-specific delivery of dexamethasone from biodegradable implants reduces formation of pericardial adhesions in rabbits [J].
Chorny, Michael ;
Mishaly, David ;
Leibowitz, Avshalom ;
Domb, Abraham J. ;
Golomb, Gershon .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2006, 78A (02) :276-282
[6]   Physicochemical properties and mechanism of drug release from ethyl cellulose matrix tablets prepared by direct compression and hot-melt extrusion [J].
Crowley, MM ;
Schroeder, B ;
Fredersdorf, A ;
Obara, S ;
Talarico, M ;
Kucera, S ;
McGinity, JW .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2004, 269 (02) :509-522
[7]   The influence of guaifenesin and ketoprofen on the properties of hot-melt extruded polyethylene oxide films [J].
Crowley, MM ;
Fredersdorf, A ;
Schroeder, B ;
Kucera, S ;
Prodduturi, S ;
Repka, MA ;
McGinity, JW .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2004, 22 (05) :409-418
[8]   Single high dose dexamethasone treatment decreases the pathological score and increases the survival rate of paraquat-intoxicated rats [J].
Dinis-Oliveira, R. J. ;
Duarte, J. A. ;
Remiao, F. ;
Sanchez-Navarro, A. ;
Bastos, M. L. ;
Carvalho, Felix .
TOXICOLOGY, 2006, 227 (1-2) :73-85
[9]   Safety and pharmacokinetics of an intravitreal biodegradable implant of dexamethasone acetate in rabbit eyes [J].
Fialho, S. L. ;
Rego, M. B. ;
Siqueira, R. C. ;
Jorge, R. ;
Haddad, A. ;
Rodrigues, A. L., Jr. ;
Maia-Filho, A. ;
Silva-Cunha, A. .
CURRENT EYE RESEARCH, 2006, 31 (06) :525-534
[10]   Dexamethasone-loaded poly(ε-caprolactone) intravitreal implants:: A pilot study [J].
Fialho, Silvia Ligorio ;
Behar-Cohen, Francine ;
Silva-Cunha, Armando .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2008, 68 (03) :637-646