Improvement of upper extremity kinematics estimation using a subject-specific forearm model implemented in a kinematic chain

被引:15
作者
Fohanno, Vincent [1 ,2 ]
Lacouture, Patrick [1 ,2 ]
Colloud, Floren [1 ,2 ]
机构
[1] Univ Poitiers, Poitiers, France
[2] Inst Pprime UPR CNRS 3346, F-86962 Futuroscope, France
关键词
Global optimisation; Daily living tasks; Joint kinematics; Modelling; TIBIO-FEMORAL JOINT; IN-VIVO; GLOBAL OPTIMIZATION; KNEE KINEMATICS; FORMAL METHODS; HUMAN MOVEMENT; SKIN MARKER; ELBOW; AXIS; MOTION;
D O I
10.1016/j.jbiomech.2013.01.029
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Human movement reconstruction is still difficult due to noise generated by the use of skin markers. The a priori definition of a kinematic chain associated with a global optimisation method allows reducing these deleterious effects. When dealing with the forearm, this approach can be improved by personalising the two axes of rotation because their common modelling is not representative of joint geometry. The aim of the present study is to evaluate the kinematic effects of personalising these two axes of rotation, determined by a functional method and implemented in a kinematic chain (AXIS model). The AXIS model was compared with a reference model (ISB model), in which the forearm axes of rotation were defined according to the recommendations of the International Society of Biomechanics. The kinematic comparison (15 subjects and 3 tasks) was based on marker residuals (actual versus model-determined), joint kinematic root mean square differences (AXIS versus ISB) and joint amplitudes (AXIS versus ISB). The AXIS model improved the pose of the forearm and hand. The reduction in marker residuals for these segments ranged between 23% and 60%. The use of a functional method was also beneficial in personalising the flexion-extension and pronation-supination axes of the forearm. The contribution of pronation-supination, in terms of joint amplitudes, was increased by 15% during the specific task. The approach developed in this study is all the more interesting since this forearm model could be integrated into a kinematic chain to be used with a global approach becoming increasingly popular in biomechanics. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1053 / 1059
页数:7
相关论文
共 44 条
[21]   Design of patient-specific gait modifications for knee osteoarthritis rehabilitation [J].
Fregly, Benjamin J. ;
Reinbolt, Jeffrey A. ;
Rooney, Kelly L. ;
Mitchell, Kim H. ;
Chmielewski, Terese L. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (09) :1687-1695
[22]   Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using 'interventional' MRI [J].
Johal, P ;
Williams, A ;
Wragg, P ;
Hunt, D ;
Gedroyc, W .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :269-276
[23]  
Kapandji A.I., 2007, The physiology of the joints
[24]   A framework for the definition of standardized protocols for measuring upper-extremity kinematics [J].
Kontaxis, A. ;
Cutti, A. G. ;
Johnson, G. R. ;
Veeger, H. E. J. .
CLINICAL BIOMECHANICS, 2009, 24 (03) :246-253
[25]   Human movement analysis using stereophotogrammetry - Part 3. Soft tissue artifact assessment and compensation [J].
Leardini, A ;
Chiari, L ;
Della Croce, U ;
Cappozzo, A .
GAIT & POSTURE, 2005, 21 (02) :212-225
[26]  
Leboucher J., 2009, GAIT POSTURE, V30, pS60
[27]   Dynamic tracking of the scapula using skin-mounted markers [J].
Lovern, B. ;
Stroud, L. A. ;
Evans, R. O. ;
Evans, S. L. ;
Holt, C. A. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H7) :823-831
[28]   Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints [J].
Lu, TW ;
O'Connor, JJ .
JOURNAL OF BIOMECHANICS, 1999, 32 (02) :129-134
[29]   Correction of axis misalignment in the analysis of knee rotations [J].
Marin, F ;
Mannel, H ;
Claes, L ;
Dürselen, L .
HUMAN MOVEMENT SCIENCE, 2003, 22 (03) :285-296
[30]   Deviation of skin marker from bone target during movement of the scapula [J].
Matsui, K ;
Shimada, K ;
Andrew, PD .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2006, 11 (02) :180-184