Closed-Loop Control of Myoelectric Prostheses With Electrotactile Feedback: Influence of Stimulation Artifact and Blanking

被引:45
作者
Hartmann, Cornelia [1 ]
Dosen, Strahinja [1 ]
Amsuess, Sebastian [1 ]
Farina, Dario [1 ]
机构
[1] Univ Gottingen, Univ Med Ctr Gottingen, Dept Neurorehabil Engn, D-37075 Gottingen, Germany
关键词
Closed loop systems; electrical stimulation; feedback; pattern recognition; prosthetic hand; PHANTOM LIMB PAIN; SENSORY FEEDBACK; ELECTRICAL-STIMULATION; SYSTEM; HAND;
D O I
10.1109/TNSRE.2014.2357175
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electrocutaneous stimulation is a promising approach to provide sensory feedback to amputees, and thus close the loop in upper limb prosthetic systems. However, the stimulation introduces artifacts in the recorded electromyographic (EMG) signals, which may be detrimental for the control of myoelectric prostheses. In this study, artifact blanking with three data segmentation approaches was investigated as a simple method to restore the performance of pattern recognition in prosthesis control (eight motions) when EMG signals are corrupted by stimulation artifacts. The methods were tested over a range of stimulation conditions and using four feature sets, comprising both time and frequency domain features. The results demonstrated that when stimulation artifacts were present, the classification performance improved with blanking in all tested conditions. In some cases, the classification performance with blanking was at the level of the benchmark (artifact-free data). The greatest pulse duration and frequency that allowed a full performance recovery were 400 and 150 Hz, respectively. These results show that artifact blanking can be used as a practical solution to eliminate the negative influence of the stimulation artifact on EMG pattern classification in a broad range of conditions, thus allowing to close the loop in myoelectric prostheses using electrotactile feedback.
引用
收藏
页码:807 / 816
页数:10
相关论文
共 26 条
[1]   ELECTRICAL-STIMULATION AND MYOELECTRIC CONTROL - A THEORETICAL AND APPLIED STUDY RELEVANT TO PROSTHESIS SENSORY FEEDBACK [J].
ALMSTROM, C ;
ANANI, A ;
HERBERTS, P ;
KORNER, L .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1981, 19 (05) :645-653
[2]  
[Anonymous], 2004, 9 ANN C INT FES SOC
[3]  
Antfolk C, 2013, EXPERT REV MED DEVIC, V10, P45, DOI [10.1586/erd.12.68, 10.1586/ERD.12.68]
[4]   SPREAD OF MONO-SYNAPTIC AND POLYSYNAPTIC CONNECTIONS WITHIN CATS MOTOR CORTEX [J].
ASANUMA, H ;
ROSEN, I .
EXPERIMENTAL BRAIN RESEARCH, 1973, 16 (05) :507-520
[5]  
Di Pino G, 2012, P IEEE RAS-EMBS INT, P1831, DOI 10.1109/BioRob.2012.6290808
[6]   Sensory feedback prosthesis reduces phantom limb pain: Proof of a principle [J].
Dietrich, Caroline ;
Walter-Walsh, Katrin ;
Preissler, Sandra ;
Hofmann, Gunther O. ;
Witte, Otto W. ;
Miltner, Wolfgang H. R. ;
Weiss, Thomas .
NEUROSCIENCE LETTERS, 2012, 507 (02) :97-100
[7]   A robust, real-time control scheme for multifunction myoelectric control [J].
Englehart, K ;
Hudgins, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (07) :848-854
[8]   Effect of sensory discrimination training on cortical reorganisation and phantom limb pain [J].
Flor, H ;
Denke, C ;
Schaefer, M ;
Grüsser, S .
LANCET, 2001, 357 (9270) :1763-1764
[9]   EMG signals detection and processing for on-line control of functional electrical stimulation [J].
Frigo, C ;
Ferrarin, M ;
Frasson, W ;
Pavan, E ;
Thorsen, R .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2000, 10 (05) :351-360
[10]  
Arieta AH, 2005, P ANN INT IEEE EMBS, P6919