Quantifying the Hawthorne Effect in Hand Hygiene Compliance Through Comparing Direct Observation With Automated Hand Hygiene Monitoring

被引:152
作者
Hagel, Stefan [1 ,2 ]
Reischke, Jana [1 ]
Kesselmeier, Miriam [2 ,3 ]
Winning, Johannes [4 ]
Gastmeier, Petra [5 ]
Brunkhorst, Frank M. [2 ,4 ,6 ,7 ]
Scherag, Andre [2 ,3 ]
Pletz, Mathias W. [1 ]
机构
[1] Jena Univ Hosp, Ctr Infect Dis & Infect Control, D-07747 Jena, Germany
[2] Jena Univ Hosp, Ctr Sepsis Control & Care, D-07747 Jena, Germany
[3] Jena Univ Hosp, Ctr Sepsis Control & Care, Res Grp Clin Epidemiol, D-07747 Jena, Germany
[4] Jena Univ Hosp, Clin Anesthesiol & Intens Care Med, D-07747 Jena, Germany
[5] Charite, Natl Reference Ctr Surveillance Nosocomial Infect, Inst Hyg & Environm Med, D-13353 Berlin, Germany
[6] Jena Univ Hosp, Ctr Clin Studies, D-07747 Jena, Germany
[7] Jena Univ Hosp, Paul Martini Sepsis Res Grp, D-07747 Jena, Germany
关键词
INTENSIVE-CARE UNITS; 5; MOMENTS; SYSTEM;
D O I
10.1017/ice.2015.93
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
OBJECTIVE. To quantify the Hawthorne effect of hand hygiene performance among healthcare workers using direct observation. DESIGN. Prospective observational study. SETTING. Intensive care unit, university hospital. METHODS. Direct observation of hand hygiene compliance over 48 audits of 2 hours each. Simultaneously, hand hygiene events (HHEs) were recorded using electronic alcohol-based handrub dispensers. Directly observed and electronically recorded HHEs during the 2 hours of direct observation were compared using Spearman correlations and Bland-Altman plots. To quantify the Hawthorne effect, we compared the number of electronically recorded HHEs during the direct observation periods with the re-scaled electronically recorded HHEs in the 6 remaining hours of the 8-hour working shift. RESULTS. A total of 3,978 opportunities for hand hygiene were observed during the 96 hours of direct observation. Hand hygiene compliance was 51% (95% CI, 49%-53%). There was a strong positive correlation between directly observed compliance and electronically recorded HHEs (p = 0.68 [95% CI, 0.49-0.81], P <.0001). In the 384 hours under surveillance, 4,180 HHEs were recorded by the electronic dispensers. Of those, 2,029 HHEs were recorded during the 96 hours in which direct observation was also performed, and 2,151 HHEs were performed in the remaining 288 hours of the same working shift that were not under direct observation. Healthcare workers performed 8 HHEs per hour when not under observation compared with 21 HHEs per hour during observation. CONCLUSIONS. Directly and electronically observed HHEs were in agreement. We observed a marked influence of the Hawthorne effect on hand hygiene performance.
引用
收藏
页码:957 / 962
页数:6
相关论文
共 18 条
  • [1] Preventing the Transmission of Multidrug-Resistant Organisms: Modeling the Relative Importance of Hand Hygiene and Environmental Cleaning Interventions
    Barnes, Sean L.
    Morgan, Daniel J.
    Harris, Anthony D.
    Carling, Phillip C.
    Thom, Kerri A.
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2014, 35 (09) : 1156 - 1162
  • [2] Measuring Healthcare Worker Hand Hygiene Activity: Current Practices and Emerging Technologies
    Boyce, John M.
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2011, 32 (10) : 1016 - 1028
  • [3] Introduction of an electronic monitoring system for monitoring compliance with Moments 1 and 4 of the WHO "My 5 Moments for Hand Hygiene" methodology
    Cheng, Vincent C. C.
    Tai, Josepha W. M.
    Ho, Sara K. Y.
    Chan, Jasper F. W.
    Hung, Kwan Ngai
    Ho, Pak Leung
    Yuen, Kwok Yung
    [J]. BMC INFECTIOUS DISEASES, 2011, 11
  • [4] Observer Bias in Hand Hygiene Compliance Reporting
    Dhar, Sorabh
    Tansek, Ryan
    Toftey, Elizabeth A.
    Dziekan, Beth A.
    Chevalier, Thomas C.
    Bohlinger, Connie G.
    Fitch, Michelle
    Flanagan, Margaret E.
    Chopra, Teena
    Marchaim, Dror
    Kaye, Keith S.
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2010, 31 (08) : 869 - 870
  • [5] Compliance with antiseptic hand rub use in intensive care units:: The Hawthorne effect
    Eckmanns, Tim
    Bessert, Jan
    Behnke, Michael
    Gastmeier, Petra
    Rueden, Henning
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2006, 27 (09) : 931 - 934
  • [6] Ellingson K, 2014, INFECT CONT HOSP EP, V35, P937, DOI [10.1017/S0899823X00193900, 10.1086/677145]
  • [7] Systematic Review of Studies on Compliance with Hand Hygiene Guidelines in Hospital Care
    Erasmus, Vicki
    Daha, Thea J.
    Brug, Hans
    Richardus, Jan Hendrik
    Behrendt, Myra D.
    Vos, Margreet C.
    van Beeck, Ed F.
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2010, 31 (03) : 283 - 294
  • [8] Measuring handwashing performance in health service audits and research studies
    Gould, D. J.
    Chudleigh, J.
    Drey, N. S.
    Moralejo, D.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2007, 66 (02) : 109 - 115
  • [9] Measurement of compliance with hand hygiene
    Haas, J. P.
    Larson, E. L.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2007, 66 (01) : 6 - 14
  • [10] Effectiveness of a hospital-wide educational programme for infection control to reduce the rate of health-care associated infections and related sepsis (ALERTS) - methods and interim results
    Hagel, S.
    Ludewig, K.
    Frosinski, J.
    Hutagalung, R.
    Porzelius, C.
    Gastmeier, P.
    Harbarth, S.
    Pletz, M. W.
    Brunkhorst, F. M.
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2013, 138 (34-35) : 1717 - 1722