Influence of cracks on leakage and obturation efficiency of root-end filling materials after ultrasonic preparation: An in vitro evaluation

被引:0
作者
De Bruyne, Mieke A. A. [1 ]
De Moor, Roeland J. G. [1 ]
机构
[1] Univ Ghent, Dept Operat Dent & Endodontol, Sch Dent, Ghent Univ Hosp, B-9000 Ghent, Belgium
来源
QUINTESSENCE INTERNATIONAL | 2008年 / 39卷 / 08期
关键词
crack; Fuji IX; glass-ionomer cement; leakage; MTA; obturation; periradicular surgery; root-end filling; seal;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate (1) the apical seal of root-end cavities using mineral trioxide aggregate (MTA) and glass-ionomer cement in teeth with and without cracks after ultrasonic root-end preparation and (2) the obturation efficiency of the materials in the root-end cavities. Method and Materials: Sixty teeth with root-end cavities were divided into 3 groups: teeth without cracks (-) (group A) and teeth with cracks (+) (group 13). The third group (4 teeth) served as a control. Groups A and B were each divided into 2 subgroups: Groups 1 A and 1 B were filled with Fuji IX capsules (GC) after treatment with cavity conditioner; groups 2A and 2B were filled with white MTA (Dentsply). The teeth were immersed in india ink and cleared. Apical leakage was measured from the resection surface to the maximal point of ink infiltration. Obturation efficiency was scored as good (acceptable), irregular (acceptable), or poor (unacceptable). Statistical analysis was performed using nonparametric and Fisher exact tests. Results: Apical leakage could be arranged in the following order: Fuji IX+ > MTA+ > Fuji IX- > MTA-. Significant differences between Fuji IX- and Fuji IX+ (P <.001) and between MTA- and MTA+ (P <.001) were demonstrated. Fuji IX showed significantly more unacceptable fillings than did MTA (P <.005). No correlation between obturation efficiency and apical leakage was demonstrated (P >.05). Conclusion: The presence of cracks originating from the root canal negatively influences the seal of root-end filling materials and is probably of major clinical importance. MTA and Fuji IX showed equal sealing capacity, but MTA showed better obturation efficiency in the root-end cavity than Fuji IX.
引用
收藏
页码:685 / 692
页数:8
相关论文
共 34 条
[1]   EFFECTS OF ULTRASONIC ROOT-END CAVITY PREPARATION ON THE ROOT APEX [J].
ABEDI, HR ;
VANMIERLO, BL ;
WILDERSMITH, P ;
TORABINEJAD, M .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 80 (02) :207-213
[2]  
ARENS DE, 1998, PRACTICAL LESSONS EN, P121
[3]   In vitro neurotoxic evaluation of root-end-filling materials [J].
Asrari, M ;
Lobner, D .
JOURNAL OF ENDODONTICS, 2003, 29 (11) :743-746
[4]  
Carr G B, 1997, Dent Clin North Am, V41, P541
[5]  
Chou HG, 1997, J FORMOS MED ASSOC, V96, P727
[6]   Capillary flow porometry to assess the seal provided by root-end filling materials in a standardized and reproducible way [J].
De Bruyne, MAA ;
De Bruyne, RJE ;
De Moor, RJG .
JOURNAL OF ENDODONTICS, 2006, 32 (03) :206-209
[7]   SEM analysis of the integrity of resected root apices of cadaver and extracted teeth after ultrasonic root-end preparation at different intensities [J].
De Bruyne, MAA ;
De Moor, RJG .
INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (05) :310-319
[8]   Longitudinal study on microleakage of three root-end filling materials by the fluid transport method and by capillary flow porometry [J].
De Bruyne, MAA ;
De Bruyne, RJE ;
Rosiers, L ;
De Moor, RJG .
INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (02) :129-136
[9]   The use of glass ionomer cements in both conventional and surgical endodontics [J].
De Bruyne, MAA ;
De Moor, RJG .
INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (02) :91-104
[10]  
De Moor RJG, 1999, ENDOD DENT TRAUMATOL, V15, P239