Correlations between corneal biomechanical properties measured with the Ocular Response Analyzer and ICare rebound tonometry

被引:58
作者
Martins Jorge, Jorge Manuel [1 ]
Gonzalez-Meijome, Jose M. [1 ]
Queiros, Antonio [1 ]
Fernandes, Paulo [1 ]
Parafita, Manuel A. [2 ]
机构
[1] Univ Minho, Dept Phys Optometry, Sch Sci, P-4710057 Braga, Portugal
[2] Univ Santiago de Compostela, Sch Opt & Optometry, Dept Surg Ophthalmol, Santiago De Compostela, Spain
关键词
corneal biomechanics; Ocular Response Analyzer; corneal thickness; rebound tonometry; intraocular pressure;
D O I
10.1097/IJG.0b013e31815f52b8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the biomechanical properties of the normal cornea, and correlate them with central and peripheral corneal thickness and age. Methods: Seventy-six right eyes of volunteers were measured with Ocular Response Analyzer (ORA), ICare rebound tonometry and an ultrasound pachymeter at corneal center and at 4 mm from corneal center in the nasal and temporal directions. Results: ICare readings were significantly correlated with central and peripheral corneal thickness and corneal biomechanical properties. Corneal resistance factor was the biomechanical parameter with the higher correlation with ICare intraocular pressure (IOP) values. Ware tonometry at center and Goldmann equivalent IOP obtained with ORA were significantly higher for thicker than thinner corneas (P < 0.05). IOP compensated for conical properties with the ORA was lower than the remaining IOP values measured in the Study. Higher correlation was found between Goldmann equivalent IOP with ORA and ICare IOP values. Conclusions: IOP values obtained with the rebound tonometer are higher in thicker corneas and are positively correlated with biomechanical corneal parameters. namely corneal resistance factor. Although corneal thickness plays a significant role in rebound tonometry, elastic and Viscous properties of the cornea seem to play a significant role in the interaction of the tonometer probe with the ocular surface. However, the mechanism behind this process is presently unknown.
引用
收藏
页码:442 / 448
页数:7
相关论文
共 25 条
  • [1] The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology
    Browning, AC
    Bhan, A
    Rotchford, AP
    Shah, S
    Dua, HS
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (11) : 1395 - 1399
  • [2] Central corneal thickness and corneal hysteresis associated with glaucoma damage
    Congdon, NG
    Broman, AT
    Bandeen-Roche, K
    Grover, D
    Quigley, HA
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) : 868 - 875
  • [3] Clinical evaluation of rebound tonometer
    Davies, LN
    Bartlett, H
    Mallen, EAH
    Wolffsohn, JS
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (02): : 206 - 209
  • [4] Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    Doughty, MJ
    Zaman, ML
    [J]. SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) : 367 - 408
  • [5] Corneal thickness: measurement and implications
    Ehlers, N
    Hjortdal, J
    [J]. EXPERIMENTAL EYE RESEARCH, 2004, 78 (03) : 543 - 548
  • [6] Comparison of the ICare® rebound tonometer with the Goldmann tonometer in a normal population
    Fernandes, P
    Díaz-Rey, JA
    Queirós, A
    Gonzalez-Meijome, JM
    Jorge, J
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (05) : 436 - 440
  • [7] Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes
    García-Resúa, C
    González-Meijome, JM
    Gilino, J
    Yebra-Pimentel, E
    [J]. OPTOMETRY AND VISION SCIENCE, 2006, 83 (02) : 102 - 107
  • [8] Age differences in central and peripheral intraocular pressure using a rebound tonometer
    Gonzalez-Meijome, J. M.
    Jorge, J.
    Queiros, A.
    Fernandes, P.
    Montes-Mico, R.
    Almeida, J. B.
    Parafita, M. A.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (12) : 1495 - 1500
  • [9] Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry
    González-Méijome, JM
    Cerviño, A
    Yebra-Pimentel, E
    Parafita, MA
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01) : 125 - 132
  • [10] Changes in corneal structure with continuous wear of high-Dk soft contact lenses:: A pilot study
    González-Méijome, JM
    González-Pérez, J
    Cerviño, A
    Yebra-Pimentel, E
    Parafita, MA
    [J]. OPTOMETRY AND VISION SCIENCE, 2003, 80 (06) : 440 - 446