Effect of framework design on crown failure

被引:46
作者
Bonfante, Estevam A. [1 ]
da Silva, Nelson R. F. A. [2 ]
Coelho, Paulo G. [2 ]
Bayardo-Gonzalez, Daniel E. [1 ]
Thompson, Van P. [2 ]
Bonfante, Gerson [1 ]
机构
[1] Univ Sao Paulo, Bauru Sch Dent, Integrated Ctr Res, Dept Prosthodont, BR-17012901 Bauru, SP, Brazil
[2] NYU, Sch Dent, Dept Biomat & Biomimet, New York, NY USA
关键词
all-ceramic; design; framework; single-crown; strength; FIXED-PARTIAL DENTURES; ALL-CERAMIC CROWNS; CERAMOMETAL RESTORATIONS; CONNECTOR DESIGN; METAL CROWNS; FRACTURE; PROSTHESES; STRENGTH;
D O I
10.1111/j.1600-0722.2008.00608.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the effect of core-design modification on the characteristic strength and failure modes of glass-infiltrated alumina (In-Ceram) (ICA) compared with porcelain fused to metal (PFM). Premolar crowns of a standard design (PFMs and ICAs) or with a modified framework design (PFMm and ICAm) were fabricated, cemented on dies, and loaded until failure. The crowns were loaded at 0.5 mm min(-1) using a 6.25 mm tungsten-carbide ball at the central fossa. Fracture load values were recorded and fracture analysis of representative samples were evaluated using scanning electron microscopy. Probability Weibull curves with two-sided 90% confidence limits were calculated for each group and a contour plot of the characteristic strength was obtained. Design modification showed an increase in the characteristic strength of the PFMm and ICAm groups, with PFM groups showing higher characteristic strength than ICA groups. The PFMm group showed the highest characteristic strength among all groups. Fracture modes of PFMs and of PFMm frequently reached the core interface at the lingual cusp, whereas ICA exhibited bulk fracture through the alumina core. Core-design modification significantly improved the characteristic strength for PFM and for ICA. The PFM groups demonstrated higher characteristic strength than both ICA groups combined.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 34 条
  • [1] Bindl A, 2002, INT J PROSTHODONT, V15, P451
  • [2] Current ceramic materials and systems with clinical recommendations: A systematic review
    Conrad, Heather J.
    Seong, Wook-Jin
    Pesun, Gor J.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2007, 98 (05) : 389 - 404
  • [3] Characterization of damage modes in dental ceramic bilayer structures
    Deng, Y
    Lawn, BR
    Lloyd, IK
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (02): : 137 - 145
  • [4] Lifetime prediction of all-ceramic bridges by computational methods
    Fischer, H
    Weber, M
    Marx, R
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 (03) : 238 - 242
  • [5] Comparison of the load at failure of soldered and nonsoldered porcelain-fused-to-metal crowns
    Kang, MS
    Ercoli, C
    Galindo, DF
    Graser, GN
    Moss, ME
    Tallents, RH
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (03) : 235 - 240
  • [6] Clinically relevant approach to failure testing of all-ceramic restorations
    Kelly, JR
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (06) : 652 - 661
  • [7] Fracture of porcelain-veneered structures in fatigue
    Kim, B.
    Zhang, Y.
    Pines, M.
    Thompson, V. P.
    [J]. JOURNAL OF DENTAL RESEARCH, 2007, 86 (02) : 142 - 146
  • [8] Maximal bite force in patients with reduced periodontal tissue support with and without splinting
    Kleinfelder, JW
    Ludwig, K
    [J]. JOURNAL OF PERIODONTOLOGY, 2002, 73 (10) : 1184 - 1187
  • [9] The effect of core framework designs on the fracture loads of all-ceramic fixed partial dentures on posterior implants
    Kokubo, Y.
    Tsumita, M.
    Sakurai, S.
    Torizuka, K.
    von Steyern, P. Vult
    Fukushima, S.
    [J]. JOURNAL OF ORAL REHABILITATION, 2007, 34 (07) : 503 - 507
  • [10] KORNFELD M, 1974, MOUTH REHABILITATION, V1, P1