MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system

被引:19
作者
Omidvari, Negar [1 ]
Topping, Geoffrey [1 ]
Cabello, Jorge [1 ]
Paul, Stephan [2 ]
Schwaiger, Markus [1 ]
Ziegler, Sibylle, I [1 ,3 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Nucl Med, Ismaninger Str 22, D-81675 Munich, Germany
[2] Tech Univ Munich, Phys Dept E18, James Franck Str 1, D-85748 Garching, Germany
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Nucl Med, Marchioninistr 15, D-81377 Munich, Germany
关键词
positron emission tomography (PET); magnetic resonance imaging (MRI); PET/MRI; SiPM; MR-compatibility; performance evaluation; POSITRON-EMISSION-TOMOGRAPHY; SILICON PHOTOMULTIPLIER PET; SIMULTANEOUS PET/MRI; PERFORMANCE EVALUATION; SCANNER; DETECTOR;
D O I
10.1088/1361-6560/aab9d1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Compromises in the design of a positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system should minimize the deterioration of image quality in both modalities, particularly when simultaneous demanding acquisitions are performed. In this work, the advantages of using individually read-out crystals with high-gain silicon photomultipliers (SiPMs) were studied with a small animal PET insert for a 7 T MRI system, in which the SiPM charge was transferred to outside the MRI scanner using coaxial cables. The interferences between the two systems were studied with three radio-frequency (RF) coil configurations. The effects of PET on the static magnetic field, flip angle distribution, RF noise, and image quality of various MRI sequences (gradient echo, spin echo, and echo planar imaging (EPI) at H-1 frequency, and chemical shift imaging at C-13 frequency) were investigated. The effects of fast-switching gradient fields and RF pulses on PET count rate were studied, while the PET insert and the readout electronics were not shielded. Operating the insert inside a H-1 volume coil, used for RF transmission and reception, limited the MRI to T1-weighted imaging, due to coil detuning and RF attenuation, and resulted in significant PET count loss. Using a surface receive coil allowed all tested MR sequences to be used with the insert, with 45-59% signal-to-noise ratio (SNR) degradation, compared to without PET. With a H-1/C-13 volume coil inside the insert and shielded by a copper tube, the SNR degradation was limited to 23-30% with all tested sequences. The insert did not introduce any discernible distortions into images of two tested EPI sequences. Use of truncated sinc shaped RF excitation pulses and gradient field switching had negligible effects on PET count rate. However, PET count rate was substantially affected by high-power RF block pulses and temperature variations due to high gradient duty cycles.
引用
收藏
页数:23
相关论文
共 37 条
[1]   Simultaneous in vivo positron emission tomography and magnetic resonance imaging [J].
Catana, Ciprian ;
Procissi, Daniel ;
Wu, Yibao ;
Judenhofer, Martin S. ;
Qi, Jinyi ;
Pichler, Bernd J. ;
Jacobs, Russell E. ;
Cherry, Simon R. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2008, 105 (10) :3705-3710
[2]   POSITRON EMISSION TOMOGRAPHY WITHIN A MAGNETIC-FIELD USING PHOTOMULTIPLIER TUBES AND LIGHTGUIDES [J].
CHRISTENSEN, NL ;
HAMMER, BE ;
HEIL, BG ;
FETTERLY, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (04) :691-697
[3]  
Delso G, 2011, J NUCL MED, V52, P1914, DOI 10.2967/jnumed.111.092726
[4]   Simultaneous PET/MR imaging with a radio frequency- penetrable PET insert [J].
Grant, Alexander M. ;
Lee, Brian J. ;
Chang, Chen-Ming ;
Levin, Craig S. .
MEDICAL PHYSICS, 2017, 44 (01) :112-120
[5]   NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system [J].
Grant, Alexander M. ;
Deller, Timothy W. ;
Khalighi, Mohammad Mehdi ;
Maramraju, Sri Harsha ;
Delso, Gaspar ;
Levin, Craig S. .
MEDICAL PHYSICS, 2016, 43 (05) :2334-2343
[6]   Characterization methods for comprehensive evaluations of shielding materials used in an MRI [J].
Gross-Weege, Nicolas ;
Dey, Thomas ;
Gebhardt, Pierre ;
Schug, David ;
Weissler, Bjoern ;
Schulz, Volkmar .
MEDICAL PHYSICS, 2018, 45 (04) :1415-1424
[7]  
Hammer B, 1990, US Patent, Patent No. [4,939,464, 4939464]
[8]   A prototype MR insertable brain PET using tileable GAPD arrays [J].
Hong, Key Jo ;
Choi, Yong ;
Jung, Jin Ho ;
Kang, Jihoon ;
Hu, Wei ;
Lim, Hyun Keong ;
Huh, Yoonsuk ;
Kim, Sangsu ;
Jung, Ji Woong ;
Kim, Kyu Bom ;
Song, Myung Sung ;
Park, Hyun-wook .
MEDICAL PHYSICS, 2013, 40 (04)
[9]   SiPM-PET with a short optical fiber bundle for simultaneous PET-MR imaging [J].
Hong, Seong Jong ;
Kang, Han Gyoo ;
Ko, Guen Bae ;
Song, In Chan ;
Rhee, June-Tak ;
Lee, Jae Sung .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12) :3869-3883
[10]   Simultaneous PET-MRI:: a new approach for functional and morphological imaging [J].
Judenhofer, Martin S. ;
Wehrl, Hans F. ;
Newport, Danny F. ;
Catana, Ciprian ;
Siegel, Stefan B. ;
Becker, Markus ;
Thielscher, Axel ;
Kneilling, Manfred ;
Lichy, Matthias P. ;
Eichner, Martin ;
Klingel, Karin ;
Reischl, Gerald ;
Widmaier, Stefan ;
Roecken, Martin ;
Nutt, Robert E. ;
Machulla, Hans-Juergen ;
Uludag, Kamil ;
Cherry, Simon R. ;
Claussen, Claus D. ;
Pichler, Bernd J. .
NATURE MEDICINE, 2008, 14 (04) :459-465