Influence of geometry on the thermal performance of water pit seasonal heat storages for solar district heating

被引:23
作者
Bai, Yakai [1 ,2 ,3 ,4 ]
Yang, Ming [1 ,2 ,5 ,6 ]
Fan, Jianhua [4 ]
Li, Xiaoxia [7 ]
Chen, Longfei [1 ]
Yuan, Guofeng [1 ,2 ,5 ,6 ]
Wang, Zhifeng [1 ,2 ,3 ,5 ,6 ]
机构
[1] Chinese Acad Sci, Key Lab Solar Thermal Energy & Photovolta Syst, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Inst Elect Engn, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Tech Univ Denmark, Dept Civil Engn, Brovej 118, DK-2800 Lyngby, Denmark
[5] Chinese Acad Sci, Inst Elect Engn, Joint Lab, Beijing 100190, Peoples R China
[6] Guangdong Five Star Solar Energy Co Ltd, Beijing 100190, Peoples R China
[7] Lanzhou Univ Technol, Lanzhou 730050, Gansu, Peoples R China
关键词
water pit; seasonal heat storage; truncated cone; storage capacity; thermal stratification; coordinate transformation; ENERGY-STORAGE; COMPUTATIONAL MODEL; COOLING SYSTEM; SIMULATION; TANK; STRATIFICATION; PUMP;
D O I
10.1007/s12273-020-0671-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
The aim of the study is to investigate the influence of geometry on the thermal capacity and stratifications of a water pit heat storage for solar district heating. A TRNSYS component model for a truncated cone water pit was developed based on the coordinate transformation method and validated by experimental results from the water pit heat storage in Huangdicheng in 2018. The thermal performance of 26 water pits with different heights and side wall slopes was calculated for 10 consecutive years. It takes four to six years for the water pit to reach steady-state operation. The operation data from the tenth year was selected to evaluate the thermal performance of each configuration. The results show that because of the thermal insulation on top of the water pit, the height to diameter ratio of a water pit with minimum annual heat loss was always smaller than 1.0. The annual storage efficiency of a water pit increases with side wall slope due to the reduced side wall area. There is an almost linear increase in the thermal stratification number of a water pit with height. With an increase in the height, thermal stratification in water pits with a steeper slope increased more gradually than water pits with a lower slope. The findings in this paper are relevant for the design optimization of water pits as seasonal thermal energy storages.
引用
收藏
页码:579 / 599
页数:21
相关论文
共 52 条
[1]   CFD analysis of thermal stratification in domestic hot water storage tank during dynamic mode [J].
Abdelhak, Olfa ;
Mhiri, Hatem ;
Bournot, Philippe .
BUILDING SIMULATION, 2015, 8 (04) :421-429
[2]  
[Anonymous], 2003, P ISES SOL WORLD C
[3]   Numerical and experimental study of an underground water pit for seasonal heat storage [J].
Bai, Yakai ;
Wang, Zhifeng ;
Fan, Jianhua ;
Yang, Ming ;
Li, Xiaoxia ;
Chen, Longfei ;
Yuan, Guofeng ;
Yang, Junfeng .
RENEWABLE ENERGY, 2020, 150 (487-508) :487-508
[4]   Thermal stratification in a cylindrical tank due to heat losses while in standby mode [J].
Bai, Yakai ;
Yang, Ming ;
Wang, Zhifeng ;
Li, Xiaoxia ;
Chen, Longfei .
SOLAR ENERGY, 2019, 185 :222-234
[5]   German central solar heating plants with seasonal heat storage [J].
Bauer, D. ;
Marx, R. ;
Nussbicker-Lux, J. ;
Ochs, F. ;
Heidemann, W. ;
Mueller-Steinhagen, H. .
SOLAR ENERGY, 2010, 84 (04) :612-623
[6]   Dimensionless numbers used to characterize stratification in water tanks for discharging at low flow rates [J].
Castell, A. ;
Medrano, M. ;
Sole, C. ;
Cabeza, L. F. .
RENEWABLE ENERGY, 2010, 35 (10) :2192-2199
[7]   Comparative study of the transient natural convection in an underground water pit thermal storage [J].
Chang, Chun ;
Wu, Zhiyong ;
Navarro, Helena ;
Li, Chuan ;
Leng, Guanghui ;
Li, Xiaoxia ;
Yang, Ming ;
Wang, Zhifeng ;
Ding, Yulong .
APPLIED ENERGY, 2017, 208 :1162-1173
[8]   Thermal Analysis of a Volumetric Solar Receiver [J].
Chen Longfei ;
Yang Ming ;
Li Jinping ;
Bai Yakai ;
Li Xiaoxia ;
Tang Wenxue ;
Yang Nancong ;
Wang Zhifeng .
JOURNAL OF THERMAL SCIENCE, 2019, 28 (06) :1176-1185
[9]   Simulation of a central solar heating system with seasonal storage in Korea [J].
Chung, M ;
Park, JU ;
Yoon, HK .
SOLAR ENERGY, 1998, 64 (4-6) :163-178
[10]  
Dahash A., 2018, P COMSOL 2018 C LAUS