Dose optimization for dual-energy contrast-enhanced digital mammography based on an energy-resolved photon-counting detector: A Monte Carlo simulation study

被引:5
|
作者
Lee, Youngjin [1 ]
Lee, Seungwan [2 ,3 ]
Kang, Sooncheol [3 ]
Eom, Jisoo [2 ]
机构
[1] Eulji Univ, Coll Hlth Sci, Dept Radiol Sci, 553 Sanseong Daero, Seongnam 13135, Gyeonggi Do, South Korea
[2] Konyang Univ, Coll Med Sci, Dept Radiol Sci, 158 Gwanjeodong Ro, Daejeon 35365, South Korea
[3] Konyang Univ, Dept Med Sci, 158 Gwanjeodong Ro, Daejeon 35365, South Korea
基金
新加坡国家研究基金会;
关键词
Dual-energy imaging; Photon-counting detector; Contrast-enhanced digital mammography; Radiation dose; Monte Carlo simulation; ADDITIONAL SPECTRAL FILTRATION; SOURCE CT; COMPUTED-TOMOGRAPHY; FEASIBILITY; NOISE; DIFFERENTIATION; QUANTIFICATION; RADIOGRAPHY; CALIBRATION; TISSUE;
D O I
10.1016/j.radphyschem.2016.11.016
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Dual-energy contrast-enhanced digital mammography (CEDM) has been used to decompose breast images and improve diagnostic accuracy for tumor detection. However, this technique causes an increase of radiation dose and an inaccuracy in material decomposition due to the limitations of conventional X-ray detectors. In this study, we simulated the dual-energy CEDM with an energy-resolved photon-counting detector (ERPCD) for reducing radiation dose and improving the quantitative accuracy of material decomposition images. The ERPCD-based dual-energy CEDM was compared to the conventional dual-energy CEDM in terms of radiation dose and quantitative accuracy. The correlation between radiation dose and image quality was also evaluated for optimizing the ERPCD-based dual-energy CEDM technique. The results showed that the material decomposition errors of the ERPCD-based dual-energy CEDM were 0.56-0.67 times lower than those of the conventional dual-energy CEDM. The imaging performance of the proposed technique was optimized at the radiation dose of 1.09 mGy, which is a half of the MGD for a single view mammogram. It can be concluded that the ERPCD-based dual-energy CEDM with an optimal exposure level is able to improve the quality of material decomposition images as well as reduce radiation dose.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [21] A novel approach to background subtraction in contrast-enhanced dual-energy digital mammography with commercially available mammography devices: Polychromaticity correction
    Contillo, Adriano
    Di Domenico, Giovanni
    Cardarelli, Paolo
    Gambaccini, Mauro
    Taibi, Angelo
    MEDICAL PHYSICS, 2015, 42 (11) : 6641 - 6650
  • [22] Susceptibility of iodine concentration map of dual-energy contrast-enhanced digital mammography for quantitative and tumor enhancement assessment
    Hwang, Yi-Shuan
    Cheung, Yun-Chung
    Lin, Yu-Ying
    Hsu, Hsiao-Lan
    Tsai, Hui-Yu
    ACTA RADIOLOGICA, 2018, 59 (08) : 893 - 901
  • [23] Assessment of a photon-counting detector for a dual-energy C-arm angiographic system
    Ahmad, Moiz
    Fahrig, Rebecca
    Pung, Leland
    Spahn, Martin
    Koester, Niko S.
    Reitz, Silke
    Moore, Teri
    Choi, Jang-Hwan
    Hinshaw, Waldo
    Xia, Yan
    Mueller, Kerstin
    MEDICAL PHYSICS, 2017, 44 (11) : 5938 - 5948
  • [24] Pediatric contrast-enhanced chest CT on a photon-counting detector CT: radiation dose and image quality compared to energy-integrated detector CT
    El-Ali, Alexander M.
    Strubel, Naomi
    Pinkney, Lynne
    Xue, Christine
    Dane, Bari
    Lala, Shailee V.
    PEDIATRIC RADIOLOGY, 2024, 54 (12) : 1984 - 1995
  • [25] Anatomical noise in contrast-enhanced digital mammography. Part II. Dual-energy imaging
    Hill, Melissa L.
    Mainprize, James G.
    Carton, Ann-Katherine
    Saab-Puong, Sylvie
    Iordache, Razvan
    Muller, Serge
    Jong, Roberta A.
    Dromain, Clarisse
    Yaffe, Martin J.
    MEDICAL PHYSICS, 2013, 40 (08)
  • [26] The effect of energy weighting on x-ray imaging based on photon counting detector: a Monte Carlo simulation
    Lee, Seung-Wan
    Choi, Yu-Na
    Cho, Hyo-Min
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Kim, Hee-Joung
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [27] Validation of a modified PENELOPE Monte Carlo code for applications in digital and dual-energy mammography
    Del Lama, L. S.
    Cunha, D. M.
    Poletti, M. E.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 137 : 151 - 156
  • [28] Material decomposition with a prototype photon-counting detector CT system: expanding a stoichiometric dual-energy CT method via energy bin optimization and K-edge imaging
    Richtsmeier, Devon
    Rodesch, Pierre-Antoine
    Iniewski, Kris
    Bazalova-Carter, Magdalena
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (05)
  • [29] Material discrimination study of dual-energy imaging using photon counting detector
    Hao Jia
    Zhang Li
    Xing Yuxiang
    Kang Kejun
    Xiao Yongshun
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 524 - 527
  • [30] Evaluation of exposure factors of dual-energy contrast-enhanced mammography to optimize radiation dose with improved image quality
    Niroshani, Sachila
    Nakamura, Tokiko
    Michiru, Nikaidou
    Negishi, Toru
    ACTA RADIOLOGICA OPEN, 2022, 11 (08)