Dose optimization for dual-energy contrast-enhanced digital mammography based on an energy-resolved photon-counting detector: A Monte Carlo simulation study

被引:5
|
作者
Lee, Youngjin [1 ]
Lee, Seungwan [2 ,3 ]
Kang, Sooncheol [3 ]
Eom, Jisoo [2 ]
机构
[1] Eulji Univ, Coll Hlth Sci, Dept Radiol Sci, 553 Sanseong Daero, Seongnam 13135, Gyeonggi Do, South Korea
[2] Konyang Univ, Coll Med Sci, Dept Radiol Sci, 158 Gwanjeodong Ro, Daejeon 35365, South Korea
[3] Konyang Univ, Dept Med Sci, 158 Gwanjeodong Ro, Daejeon 35365, South Korea
基金
新加坡国家研究基金会;
关键词
Dual-energy imaging; Photon-counting detector; Contrast-enhanced digital mammography; Radiation dose; Monte Carlo simulation; ADDITIONAL SPECTRAL FILTRATION; SOURCE CT; COMPUTED-TOMOGRAPHY; FEASIBILITY; NOISE; DIFFERENTIATION; QUANTIFICATION; RADIOGRAPHY; CALIBRATION; TISSUE;
D O I
10.1016/j.radphyschem.2016.11.016
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Dual-energy contrast-enhanced digital mammography (CEDM) has been used to decompose breast images and improve diagnostic accuracy for tumor detection. However, this technique causes an increase of radiation dose and an inaccuracy in material decomposition due to the limitations of conventional X-ray detectors. In this study, we simulated the dual-energy CEDM with an energy-resolved photon-counting detector (ERPCD) for reducing radiation dose and improving the quantitative accuracy of material decomposition images. The ERPCD-based dual-energy CEDM was compared to the conventional dual-energy CEDM in terms of radiation dose and quantitative accuracy. The correlation between radiation dose and image quality was also evaluated for optimizing the ERPCD-based dual-energy CEDM technique. The results showed that the material decomposition errors of the ERPCD-based dual-energy CEDM were 0.56-0.67 times lower than those of the conventional dual-energy CEDM. The imaging performance of the proposed technique was optimized at the radiation dose of 1.09 mGy, which is a half of the MGD for a single view mammogram. It can be concluded that the ERPCD-based dual-energy CEDM with an optimal exposure level is able to improve the quality of material decomposition images as well as reduce radiation dose.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [1] Contrast-enhanced spectral mammography based on a photon-counting detector: Quantitative accuracy and radiation dose
    Lee, Seungwan
    Kang, Sooncheol
    Eom, Jisoo
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [2] Quantification of breast composition by using a dual-energy technique with a photon-counting detector: Monte Carlo simulation studies
    Lee, Seungwan
    Choi, Yu-Na
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (02) : 305 - 312
  • [3] Performance evaluation of total variation (TV) denoising technique for dual-energy contrast-enhanced digital mammography (CEDM) with photon counting detector (PCD): Monte Carlo simulation study
    Lee, Seungwan
    Lee, Youngjin
    RADIATION PHYSICS AND CHEMISTRY, 2019, 156 : 94 - 100
  • [4] A feasibility study of projection-based energy weighting based on a photon-counting detector in contrast-enhanced digital subtraction mammography: A simulation study
    Choi, Sunghoon
    Lee, Seungwan
    Choi, Yu-Na
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (12) : 1900 - 1906
  • [5] Quantification of breast composition by using a dual-energy technique with a photon-counting detector: Monte Carlo simulation studies
    Seungwan Lee
    Yu-Na Choi
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2014, 64 : 305 - 312
  • [6] Quantitative material decomposition using spectral computed tomography with an energy-resolved photon-counting detector
    Lee, Seungwan
    Choi, Yu-Na
    Kim, Hee-Joung
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18) : 5457 - 5482
  • [7] A Monte Carlo simulation study of the effect of energy windows in computed tomography images based on an energy-resolved photon counting detector
    Lee, Seung-Wan
    Choi, Yu-Na
    Cho, Hyo-Min
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Kim, Hee-Joung
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (15) : 4931 - 4949
  • [8] Feasibility study of contrast enhanced digital mammography based on photon-counting detector by projection-based weighting technique: A simulation study
    Lee, Minjae
    Lee, Donghoon
    Jo, Byungdu
    Kim, Hyemi
    Kim, Dohyeon
    Choi, Seungyeon
    Kim, Hee-Joung
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [9] Energy-resolved CT imaging with a photon-counting silicon-strip detector
    Persson, Mats
    Huber, Ben
    Karlsson, Staffan
    Liu, Xuejin
    Chen, Han
    Xu, Cheng
    Yveborg, Moa
    Bornefalk, Hans
    Danielsson, Mats
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22) : 6709 - 6727
  • [10] Preliminary Evaluation of A Novel Energy-Resolved Photon-Counting Gamma Ray Detector
    Meng, L. J.
    Tan, J. W.
    Spartiotis, K.
    Schulman, T.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5115 - +