Self-Navigated Three-Dimensional Ultrashort Echo Time Technique for Motion-Corrected Skull MRI

被引:11
作者
Lee, Hyunyeol [1 ]
Zhao, Xia [1 ]
Song, Hee Kwon [1 ]
Wehrli, Felix W. [1 ]
机构
[1] Univ Penn, Perelman Sch Med, Lab Struct Physiol & Funct Imaging LSPFI, Dept Radiol, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
Ultrashort echo time (UTE); skull MRI; motion correction; self-navigation; k-space trajectory correction; MAGNETIC-RESONANCE; RECONSTRUCTION; OPTIMIZATION; REGISTRATION; STRATEGY; IMAGES; ROBUST; MYELIN;
D O I
10.1109/TMI.2020.2978405
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Ultrashort echo time (UTE) MRI is capable of detecting signals from protons with very short T-2 relaxation times, and thus has potential for skull-selective imaging as a radiation-free alternative to computed tomography. However, relatively long scan times make the technique vulnerable to artifacts from involuntary subject motion. Here, we developed a self-navigated, three-dimensional (3D) UTE pulse sequence, which builds on dual-RF, dual-echo UTE imaging, and a retrospective motion correction scheme for motion-resistant skull MRI. Full echo signals in the second readout serve as a self-navigator that yields a time-course of center of mass, allowing for adaptive determination of motion states. Furthermore, golden-means based k-space trajectory was employed to achieve a quasi-uniform distribution of sampling views on a spherical k-space surface for any subset of the entire data collected, thereby allowing reconstruction of low-resolution images pertaining to each motion state for subsequent estimation of rigid-motion parameters. Finally, the extracted trajectory of the head was used to make the whole k-space datasets motion-consistent, leading to motion-corrected, high-resolution images. Additionally, we posit that hardware-related k-space trajectory errors, if uncorrected, result in obscured bone contrast. Thus, a calibration scan was performed once to measure k-space encoding locations, subsequently used during image reconstruction of actual imaging data. In vivo studies were performed to evaluate the effectiveness of the proposed correction schemes in combination with approaches to accelerated bone-selective imaging. Results illustrating effective removal of motion artifacts and clear depiction of skull bone voxels suggest that the proposed method is robust to intermittent head motions during scanning.
引用
收藏
页码:2869 / 2880
页数:12
相关论文
共 54 条
  • [1] Gradient characterization using a Fourier-transform technique
    Alley, MT
    Glover, GH
    Pelc, NJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) : 581 - 587
  • [2] Adaptive retrospective correction of motion artifacts in cranial MRI with multicoil three-dimensional radial acquisitions
    Anderson, Ashley G., III
    Velikina, Julia
    Block, Walter
    Wieben, Oliver
    Samsonov, Alexey
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (04) : 1094 - 1103
  • [3] ANDERSON PG, 1993, APPLICATIONS OF FIBONACCI NUMBERS, VOL 5, P1
  • [4] Characterization and Correction of System Delays and Eddy Currents for MR Imaging with Ultrashort Echo-Time and Time-Varying Gradients
    Atkinson, Ian C.
    Lu, Aiming
    Thulborn, Keith R.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (02) : 532 - 537
  • [5] Single-point ramped imaging with T-1 enhancement (SPRITE)
    Balcom, BJ
    MacGregor, RP
    Beyea, SD
    Green, DP
    Armstrong, RL
    Bremner, TW
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES A, 1996, 123 (01) : 131 - 134
  • [6] Augmented generalized SENSE reconstruction to correct for rigid body motion
    Bammer, Roland
    Aksoy, Murat
    Liu, Chunlei
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (01) : 90 - 102
  • [7] Matrix description of general motion correction applied to multishot images
    Batchelor, PG
    Atkinson, D
    Irarrazaval, P
    Hill, DLG
    Hajnal, J
    Larkman, D
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) : 1273 - 1280
  • [8] LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING
    BERGIN, CJ
    PAULY, JM
    MACOVSKI, A
    [J]. RADIOLOGY, 1991, 179 (03) : 777 - 781
  • [9] block kai tobias, 2014, Investigative Magnetic Resonance Imaging, V18, P87
  • [10] Characterizing and Correcting Gradient Errors in Non-Cartesian Imaging: Are Gradient Errors Linear Time-Invariant (LTI)?
    Brodsky, Ethan K.
    Samsonov, Alexey A.
    Block, Walter F.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (06) : 1466 - 1476