The effect of SO2 on the sensitive layer of a NOx dosimeter

被引:9
作者
Gross, A. [1 ]
Hanft, D. [1 ]
Beulertz, G. [1 ]
Marr, I. [1 ]
Kubinski, D. J. [2 ]
Visser, J. H. [2 ]
Moos, R. [1 ]
机构
[1] Univ Bayreuth, D-95440 Bayreuth, Germany
[2] Ford Res & Adv Engn, Dearborn, MI 48124 USA
关键词
Low level NOx detection; SO2; poisoning; Dosimeter; sensor; Lean NOx trap; NOx storage and reduction catalyst; EXHAUST; STORAGE; SENSOR; TRAP; CATALYSTS; ADSORBER; MODEL;
D O I
10.1016/j.snb.2012.10.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The accumulating-type or integrating-type NOx sensor works like a dosimeter being well suited for long-term total amount detection of low levels of NO and NO2 while information about the instantaneous NOx concentration is obtained from the signal derivative. A potassium-based lean NOx trap material, known from automotive catalysts, is applied as sensitive material. It accumulates NOx in the form of nitrates and thereby changes its conductivity with the NOx loading state. Since SO2 is known to poison the catalytic properties of LNTs, the effect of SO2 on the sensing characteristics is addressed now. The competition between SO2 and NO2 for the accessible storage sites was found to affect the sensor signal in two ways: due to sulfate formation, the resistance of the LNT material decreases in the presence of SO2 and the accumulating NOx sensing properties are strongly reduced. However, a high reversibility of sulfur poisoning was obtained by desulfurization of the sensitive device at 650 degrees C in H-2 containing gas. The results reveal that with the presented setup, SO2 detection is possible with a linear correlation between the conductivity and the exposed SO2 amount. Since at 380 degrees C, the sensitivity to SO2 is about half compared to NOx, cross sensitivities need to be concerned. At higher temperatures nitrates are decomposed and the sensor is selective to SO2. (C) 2012 Elsevier B. V. All rights reserved.
引用
收藏
页码:153 / 161
页数:9
相关论文
共 35 条
[1]   Engines and exhaust after treatment systems for future automotive applications [J].
Alkemade, Ulrich G. ;
Schumann, Bemd .
SOLID STATE IONICS, 2006, 177 (26-32) :2291-2296
[2]   Determining the total amount of NOx in a gas stream - Advances in the accumulating gas sensor principle [J].
Beulertz, G. ;
Gross, A. ;
Moos, R. ;
Kubinski, D. J. ;
Visser, J. H. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 175 :157-162
[3]   Composite Effect of Solid Electrolytes based on Alkali Carbonates and Sulfates [J].
Brosda, S. ;
Bouwmeester, H. J. M. ;
Guth, U. .
IONICS, 1996, 2 (3-4) :323-328
[4]   STUDY OF ELECTRICAL-CONDUCTIVITY AND TRANSITION POINTS OF POTASSIUM CARBONATE [J].
CERISIER, P ;
ROUX, F .
SOLID STATE COMMUNICATIONS, 1978, 26 (10) :661-663
[5]  
Chen H. Y., 2010, US Patent Application, Patent No. 20100146935
[6]   Thermal decomposition of dispersed and bulk-like NOx species in model NOx trap materials [J].
Chen, XY ;
Schwank, J ;
Li, J ;
Schneider, WF ;
Goralski, CT ;
Schmitz, PJ .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2005, 61 (1-2) :164-175
[7]   Overview of the fundamental reactions and degradation mechanisms of NOx storage/reduction catalysts [J].
Epling, WS ;
Campbell, LE ;
Yezerets, A ;
Currier, NW ;
Parks, JE .
CATALYSIS REVIEWS-SCIENCE AND ENGINEERING, 2004, 46 (02) :163-245
[8]   SO2 adsorption capacity of K2CO3-impregnated activated carbon as a function of K2CO3 content loaded by soaking and incipient wetness [J].
Fortier, H. ;
Zelenietz, C. ;
Dahn, T. R. ;
Westreich, P. ;
Stevens, D. A. ;
Dahn, J. R. .
APPLIED SURFACE SCIENCE, 2007, 253 (06) :3201-3207
[9]   Determination of the NOx Loading of an Automotive Lean NOx Trap by Directly Monitoring the Electrical Properties of the Catalyst Material Itself [J].
Fremerey, Peter ;
Reiss, Sebastian ;
Geupel, Andrea ;
Fischerauer, Gerhard ;
Moos, Ralf .
SENSORS, 2011, 11 (09) :8261-8280
[10]   SOLID-STATE DETECTORS FOR POTENTIOMETRIC DETERMINATION OF GASEOUS OXIDES .1. MEASUREMENT IN AIR [J].
GAUTHIER, M ;
CHAMBERLAND, A .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1977, 124 (10) :1579-1583