Numerical investigation on the effects of building configuration on discharge coefficient for a cross-ventilated dairy building model

被引:14
作者
Yi, Qianying [1 ]
Li, Hao [1 ]
Wang, Xiaoshuai [2 ]
Zong, Chao [3 ]
Zhang, Guoqiang [1 ]
机构
[1] Aarhus Univ, Dept Engn, Blichers Alle 20,POB 50, DK-8830 Tjele, Denmark
[2] Zhejiang Univ, Coll Biosyst Engn & Food Sci, Yuhangtang Rd 866, Hangzhou 310058, Zhejiang, Peoples R China
[3] China Agr Univ, Coll Water Resources & Civil Engn, Qinghua Donglu 17, Beijing 100083, Peoples R China
关键词
Orifice equation; Discharge coefficient; Naturally-ventilated dairy building; Opening configurations; Roof slope; Numerical simulation; ATMOSPHERIC BOUNDARY-LAYER; DRIVEN NATURAL VENTILATION; AIR EXCHANGE-RATE; CFD SIMULATION; WIND; FLOW; PREDICTION; ENVIRONMENT; VALIDATION; GUIDELINES;
D O I
10.1016/j.biosystemseng.2019.04.003
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
To estimate the ventilation rate of buildings, the orifice equation with a fixed discharge coefficient (C-d) is often applied. However, values of C-d may be not a constant for the openings of naturally-ventilated dairy buildings. The main objective of this study was to investigate the influence of the building configurations on the C-d value. In addition, since the value of the pressure difference across the opening is crucial to the application of the orifice equation, another objective was to evaluate the accuracy of using the orifice plate method in pressure difference measurements. The investigations were carried out using computational fluid dynamics simulations. The results showed that applying the orifice plate method to measure the pressure drop could result in up to 18.9% relative error in estimates of C-d for the case with an opening ratio of 81.4%. Additionally, the value of C-d was found to be dependent on the opening ratio, the inlet opening position, and the inlet-to-outlet area ratio, but it was independent of the outlet opening position and the roof slope. It can be concluded that the C-d value should be specified according to the opening configurations in the application of the orifice equation. (C) 2019,IAgrE. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:107 / 122
页数:16
相关论文
共 48 条
[1]  
[Anonymous], P ROOMV 2002 COP DEN
[2]  
[Anonymous], P CIBSE A
[3]  
[Anonymous], 2009, ASHRAE Handbook|Fundamentals
[4]  
ASME, 2004, FLOW MEAS PTC 19 5
[5]  
Bickert W.G., 2000, Dairy Freestall Housing and Equipment (MWPS-7)
[6]   CFD evaluation of wind speed conditions in passages between parallel buildings - effect of wall-function roughness modifications for the atmospheric boundary layer flow [J].
Blocken, Bert ;
Carmeliet, Jan ;
Stathopoulos, Ted .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2007, 95 (9-11) :941-962
[7]   CFD simulation of the atmospheric boundary layer: wall function problems [J].
Blocken, Bert ;
Stathopoulos, Ted ;
Carmeliet, Jan .
ATMOSPHERIC ENVIRONMENT, 2007, 41 (02) :238-252
[8]  
CD-Adapco, 2017, STAR CCM V12 02 US G
[9]   Ventilation performance prediction for buildings: A method overview and recent applications [J].
Chen, Qingyan .
BUILDING AND ENVIRONMENT, 2009, 44 (04) :848-858
[10]   On-site assessment of the discharge coefficient of open windows [J].
Cruz, Hildebrando ;
Viegas, Joao Carlos .
ENERGY AND BUILDINGS, 2016, 126 :463-476