Coordinated Control of DFIG's RSC and GSC Under Generalized Unbalanced and Distorted Grid Voltage Conditions

被引:131
作者
Hu, Jiabing [1 ]
Xu, Hailiang [1 ]
He, Yikang [1 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Converter; coordinated control; distortion; doubly fed induction generator (DFIG); imbalance; modeling; wind turbine; INDUCTION WIND GENERATOR; NETWORK CONDITIONS; CONTROL SCHEME; SYSTEMS; CONVERTERS;
D O I
10.1109/TIE.2012.2217718
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes a coordinated control of the rotor-side converter (RSC) and grid-side converter (GSC) of a doubly fed induction generator (DFIG)-based wind-turbine generation system under generalized unbalanced and/or distorted grid voltage conditions. The system behaviors of the RSC and GSC during supply imbalance and distortion are investigated. To enhance the fault ride-through operation capability, the RSC is properly controlled to eliminate the torque oscillations, whereas the GSC is carefully designed to ensure constant active power output from the overall DFIG generation system. To achieve simultaneous regulation of the positive-/negative-sequence currents and fifth-/seventh-order harmonic currents for both the RSC and GSC, a novel current controller, consisting of a conventional proportional-integral regulator and a dual-frequency resonant compensator, is proposed and implemented in the positive (dq)(+) reference frame. The simulation and experiment studies demonstrate the correctness of the developed model and the effectiveness of the suggested control strategy for DFIG-based wind-turbine systems under such adverse grid conditions.
引用
收藏
页码:2808 / 2819
页数:12
相关论文
共 21 条
  • [1] A Dynamic LVRT Solution for Doubly Fed Induction Generators
    Abdel-Baqi, Omar
    Nasiri, Adel
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (01) : 193 - 196
  • [2] [Anonymous], 2010, P 19 INT C EL MACH I
  • [3] Brekken T, 2003, IEEE POWER ELECTRON, P760
  • [4] Control of a doubly fed induction wind generator under unbalanced grid voltage conditions
    Brekken, Ted K. A.
    Mohan, Ned
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) : 129 - 135
  • [5] Fan Lingling, 2009, POW EN SOC GEN M PES, V10, P1
  • [6] Proportional integral plus multi-frequency resonant current controller for grid-connected voltage source converter under imbalanced and distorted supply voltage conditions
    Hu, Jia-bing
    Zhang, Wei
    Wang, Hong-sheng
    He, Yi-kang
    Xu, Lie
    [J]. JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2009, 10 (10): : 1532 - 1540
  • [7] Dynamic Modeling and Improved Control of DFIG Under Distorted Grid Voltage Conditions
    Hu, Jiabing
    Nian, Heng
    Xu, Hailiang
    He, Yikang
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (01) : 163 - 175
  • [8] DFIG wind generation systems operating with limited converter rating considered under unbalanced network conditions - Analysis and control design
    Hu, Jiabing
    He, Yikang
    [J]. RENEWABLE ENERGY, 2011, 36 (02) : 829 - 847
  • [9] Improved Control of DFIG Systems During Network Unbalance Using PI-R Current Regulators
    Hu, Jiabing
    He, Yikang
    Xu, Lie
    Williams, Barry W.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (02) : 439 - 451
  • [10] Effects of Voltage Unbalance and System Harmonics on the Performance of Doubly Fed Induction Wind Generators
    Kiani, Morgan
    Lee, Wei-Jen
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (02) : 562 - 568