A randomised comparison of variable-frequency automated mandatory boluses with a basal infusion for patient-controlled epidural analgesia during labour and delivery

被引:33
作者
Sia, A. T. [1 ]
Leo, S. [1 ]
Ocampo, C. E. [1 ]
机构
[1] KK Womens & Childrens Hosp, Dept Womens Anaesthesia, Singapore, Singapore
关键词
BACKGROUND INFUSION; PAIN RELIEF; INTERMITTENT; ROPIVACAINE; SUFENTANIL; FENTANYL; PCEA;
D O I
10.1111/anae.12093
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This trial was conducted to compare the analgesic efficacy of administering variable-frequency automated boluses at a rate proportional to the patient's needs with fixed continuous basal infusion in patient-controlled epidural analgesia (PCEA) during labour and delivery. We recruited a total of 102 parturients in labour who were randomly assigned to receive either a novel PCEA with automated mandatory boluses of 5 ml administered once, twice, three or four times per hour depending on the history of the parturient's analgesic demands over the past hour (Automated bolus group), or a conventional PCEA with a basal infusion of 5 ml.h(-1) (Infusion group). The incidence of breakthrough pain requiring supplementation by an anaesthetist was significantly lower in the Automated bolus group, three out of 51 (5.9%) compared with the Infusion group, 12 out of 51 (23.5%, p = 0.023). The time-weighted mean (SD) hourly consumption of ropivacaine was similar in both groups, 10.0 (3.0) mg in the Automated bolus group vs 11.1 (3.2) mg in the Infusion group (p = 0.06). Parturients from the Automated bolus group reported higher satisfaction scores compared with those in the Infusion group, 96.5 (5.0) vs 89.2 (9.4), respectively (p < 0.001). There was no difference in the incidence of maternal side-effects and obstetric and neonatal outcomes.
引用
收藏
页码:267 / 275
页数:9
相关论文
共 18 条
[1]   Background infusion is not beneficial during labor patient-controlled analgesia with 0.1% ropivacaine plus 0.5 μg/ml sufentanil [J].
Boselli, E ;
Debon, R ;
Cimino, Y ;
Rimmelé, T ;
Allaouchiche, B ;
Chassard, D .
ANESTHESIOLOGY, 2004, 100 (04) :968-972
[2]   Comparison of intermittent epidural bolus, continuous epidural infusion and patient controlled-epidural analgesia during labor [J].
Boutros, A ;
Blary, S ;
Bronchard, R ;
Bonnet, F .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 1999, 8 (04) :236-241
[3]   Comparison of continuous background infusion plus demand dose and demand-only parturient-controlled epidural analgesia (PCEA) using ropivacaine combined with sufentanil for labor and delivery [J].
Bremerich, DH ;
Waibel, HJ ;
Mierdl, S ;
Meininger, D ;
Byhahn, C ;
Zwissler, BC ;
Ackermann, HH .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2005, 14 (02) :114-120
[4]  
Chua SMH, 2004, CAN J ANAESTH, V51, P581, DOI 10.1007/BF03018402
[5]   New techniques for labor analgesia: PCEA and CSE [J].
D'Angelo, R .
CLINICAL OBSTETRICS AND GYNECOLOGY, 2003, 46 (03) :623-632
[6]  
FERRANTE FM, 1994, ANESTH ANALG, V79, P80
[7]   Intermittent vs continuous administration of epidural ropivacaine with fentanyl for analgesia during labour [J].
Fettes, P. D. W. ;
Moore, C. S. ;
Whiteside, J. B. ;
Mcleod, G. A. ;
Wildsmith, J. A. W. .
BRITISH JOURNAL OF ANAESTHESIA, 2006, 97 (03) :359-364
[8]   Distribution of solution in the epidural space: Examination by cryomicrotome section [J].
Hogan, Q .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2002, 27 (02) :150-156
[9]   Epidural infusion: Continuous or bolus? [J].
Kaynar, AM ;
Shankar, KB .
ANESTHESIA AND ANALGESIA, 1999, 89 (02) :534-534
[10]   Comparison of computer integrated patient controlled epidural analgesia vs. conventional patient controlled epidural analgesia for pain relief in labour [J].
Lim, Y ;
Sia, AT ;
Ocampo, CE .
ANAESTHESIA, 2006, 61 (04) :339-344