Continuous glucose monitoring: quality of hypoglycaemia detection

被引:36
作者
Zijlstra, E. [1 ]
Heise, T. [1 ]
Nosek, L. [1 ]
Heinemann, L. [1 ]
Heckermann, S. [1 ]
机构
[1] Profil, Neuss, Germany
关键词
clinical trial; glycaemic control; type; 1; diabetes; CLINICAL ACCURACY;
D O I
10.1111/dom.12001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To evaluate the accuracy of a (widely used) continuous glucose monitoring (CGM)-system and its ability to detect hypoglycaemic events. Methods A total of 18 patients with type 1 diabetes mellitus used continuous glucose monitoring (Guardian REAL-Time CGMS) during two 9-day in-house periods. A hypoglycaemic threshold alarm alerted patients to sensor readings <70?mg/dl. Continuous glucose monitoring sensor readings were compared to laboratory reference measurements taken every 4?h and in case of a hypoglycaemic alarm. Results A total of 2317 paired data points were evaluated. Overall, the mean absolute relative difference (MARD) was 16.7%. The percentage of data points in the clinically accurate or acceptable Clarke Error Grid zones A?+?B was 94.6%. In the hypoglycaemic range, accuracy worsened (MARD 38.8%) leading to a failure to detect more than half of the true hypoglycaemic events (sensitivity 37.5%). Furthermore, more than half of the alarms that warn patients for hypoglycaemia were false (false alert rate 53.3%). Above the low alert threshold, the sensor confirmed 2077 of 2182 reference values (specificity 95.2%). Conclusions Patients using continuous glucose monitoring should be aware of its limitation to accurately detect hypoglycaemia.
引用
收藏
页码:130 / 135
页数:6
相关论文
共 50 条
[41]   Continuous glucose monitoring and hypoglycaemia events: unmet needs. Reply to Papaioannou TG, Snoudou D and Tsiofis C [J].
Teo, Evelyn .
DIABETOLOGIA, 2022, 65 (09) :1571-1571
[42]   The Role of Continuous Glucose Monitoring System Profiles in Diabetes [J].
Monnier, L. ;
Colette, C. ;
Owens, D. .
DIABETES STOFFWECHSEL UND HERZ, 2008, 17 :S17-S22
[43]   Continuous Glucose Monitoring: Current Use and Future Directions [J].
DeSalvo, Daniel ;
Buckingham, Bruce .
CURRENT DIABETES REPORTS, 2013, 13 (05) :657-662
[44]   Cost-Effectiveness of Inpatient Continuous Glucose Monitoring [J].
Verissimo, David ;
Pereira, Beatriz R. ;
Vinhais, Joana ;
Ivo, Catarina ;
Martins, Ana C. ;
Silva, Joao N. ;
Passos, Dolores ;
Lopes, Luis ;
de Castro, Joao Jacome ;
Marcelino, Mafalda .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
[45]   Toward an Optimal Definition of Hypoglycemia with Continuous Glucose Monitoring [J].
Mahmoudi, Zeinab ;
Del Favero, Simone ;
Jacob, Peter ;
Choudhary, Pratik .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 209
[46]   Role of Continuous Glucose Monitoring in the Management of Diabetic Pregnancy [J].
Hewapathirana, Niranjala M. ;
O'Sullivan, Esther ;
Murphy, Helen R. .
CURRENT DIABETES REPORTS, 2013, 13 (01) :34-42
[47]   Rationale and Design for a GRADE Substudy of Continuous Glucose Monitoring [J].
Larkin, Mary E. ;
Nathan, David M. ;
Bebu, Ionut ;
Krause-Steinrauf, Heidi ;
Herman, William H. ;
Higgins, John M. ;
Tiktin, Margaret ;
Cohen, Robert M. ;
Lund, Claire ;
Bergenstal, Richard M. ;
Johnson, Mary L. ;
Arends, Valerie ;
Crandall, Jill P. ;
McKee, Melissa Diane ;
Brown-Friday, Janet ;
Xhori, Entila ;
Ballentine-Cargill, Keisha ;
Duran, Sally ;
Lukin, Jennifer ;
Beringher, Stephanie ;
de la Torre, Susana Gonzalez ;
Phillips, Lawrence ;
Burgess, Elizabeth ;
Olson, Darin ;
Rhee, Mary ;
Wilson, Peter ;
Raines, Tasha Stephanie ;
Costello, Julie ;
Gullett, Chona ;
Maher-Albertelli, Maxine ;
Morehead, Folayan ;
Mungara, Radhika ;
Person, Saranjit ;
Savoye, Louise ;
Sibymon, Mabil ;
Tanukonda, Sridhar ;
White, Carol Ann ;
Holloway, Leah ;
Adams, Cynthia ;
Ross, April ;
Balasubramanyam, Ashok ;
Gonzalez, Erica ;
Wright, Charlyne ;
Hollander, Priscilla ;
Roe, Erin ;
Uy, Analyn ;
Burt, Polly ;
Estrada, Lorie ;
Chionh, Kris ;
Ismail-Beigi, Faramarz .
DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (12) :682-690
[48]   Effect of intermittently scanned continuous glucose monitoring in people with diabetes with a psychosocial indication for initiation [J].
Ssemmondo, Emmanuel ;
Deshmukh, Harshal ;
Wilmot, Emma G. ;
Adeleke, Kazeem A. ;
Shah, Najeeb ;
Walton, Chris ;
Barnes, Dennis ;
Ryder, Robert E. J. ;
Sathyapalan, Thozhukat .
DIABETES OBESITY & METABOLISM, 2024, 26 (04) :1340-1345
[49]   Severe hypoglycaemia is associated with increased risk of adverse cardiovascular complications in adults with type 1 diabetes: risk mitigation using intermittently scanned continuous glucose monitoring [J].
Eeg-Olofsson, Katarina ;
Nathanson, David ;
Spelman, Tim ;
Kyhlstedt, Mattias ;
Seibold, Alexander ;
Levrat-Guillen, Fleur ;
Bolinder, Jan .
DIABETOLOGIA, 2025, 68 (08) :1647-1656
[50]   Evaluation of continuous glucose monitoring system for detection of alterations in glucose homeostasis in pediatric patients with β-thalassemia major [J].
El-Samahy, Mona H. ;
Tantawy, Azza A. ;
Adly, Amira A. ;
Abdelmaksoud, Abeer A. ;
Ismail, Eman A. ;
Salah, Nouran Y. .
PEDIATRIC DIABETES, 2019, 20 (01) :65-72