The new Roche Vitamin D Total assay: fit for its purpose ?

被引:32
作者
Emmen, Judith M. A. [1 ]
Wielders, Jos P. M. [2 ]
Boer, Arjen-Kars [3 ]
van den Ouweland, Johannes M. W. [4 ]
Vader, Huib L. [1 ]
机构
[1] Maxima Med Ctr, Clin Chem Lab, NL-5500 MB Veldhoven, Netherlands
[2] Meander Med Ctr, Dept Clin Chem, Amersfoort, Netherlands
[3] Catharina Hosp, Clin Lab, Eindhoven, Netherlands
[4] Canisius Wilhelmina Hosp, Dept Clin Chem, Nijmegen, Netherlands
关键词
25-hydroxyvitamin D; HPLC; immunoassay; liquid chromatography-tandem mass spectrometry (LC-MS/MS); method validation; TANDEM MASS-SPECTROMETRY; 25-HYDROXYVITAMIN D; ACCURACY;
D O I
10.1515/cclm-2011-0085
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Measurement of serum 25-hydroxyvitamin D [25(OH)D] is used to assess vitamin D status. We evaluated the analytical performance of a new automated assay, Elecsys Vitamin D Total (Roche Diagnostics, Mannheim, Germany), based on competitive protein binding. Methods: The Elecsys assay was tested for imprecision, linearity and functional sensitivity at three test-sites and compared to a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, a high-performance liquid chromatography (HPLC) method and the Liaison 25(OH) Vitamin D Total immunoassay (Diasorin). Results: Imprecision testing with human serum specimens showed within-run CVs of <= 6% and between-run CVs of <= 8%. The assay was linear from 33 up to at least 111 nmol/L and showed equivalent 25(OH) D levels for matched serum and heparinized plasma samples. The assay correlated reasonable to well with LC-MS/MS (r=0.93; y=1.07x-5.04 nmol/L), HPLC (r=0.91, y=0.90x+3.03 nmol/L) and the Liaison assay (r=0.86, y=1.19x+2.80 nmol/L). Some of the samples showed large between-method differences. Conclusions: The new Elecsys assay fulfilled present analytical performance requirements and showed close agreement to other well-established methods for 25(OH) D analysis, making it fit for routine assessment of vitamin D status.
引用
收藏
页码:1969 / 1972
页数:4
相关论文
共 12 条
[1]   Current status of clinical 25-hydroxyvitamin D measurement: An assessment of between-laboratory agreement [J].
Binkley, Neil ;
Krueger, Diane C. ;
Morgan, Sarah ;
Wiebe, Donald .
CLINICA CHIMICA ACTA, 2010, 411 (23-24) :1976-1982
[2]  
Carter GD, 2011, CURR DRUG TARGETS, V12, P19
[3]   Overreporting of vitamin D deficiency with the Roche Elecsys Vitamin D3 (25-OH) method [J].
Connell, A. B. ;
Jenkins, N. ;
Black, M. ;
Pasco, J. A. ;
Kotowicz, M. A. ;
Schneider, H-G. .
PATHOLOGY, 2011, 43 (04) :368-371
[4]   State-of-the-Art Vitamin D Assays: A Comparison of Automated Immunoassays with Liquid Chromatography-Tandem Mass Spectrometry Methods [J].
Farrell, Christopher-John L. ;
Martin, Steven ;
McWhinney, Brett ;
Straub, Isabella ;
Williams, Paul ;
Herrmann, Markus .
CLINICAL CHEMISTRY, 2012, 58 (03) :531-542
[5]   Accuracy of 6 Routine 25-Hydroxyvitamin D Assays: Influence of Vitamin D Binding Protein Concentration [J].
Heijboer, Annemieke C. ;
Blankenstein, Marinus A. ;
Kema, Ido P. ;
Buijs, Madelon M. .
CLINICAL CHEMISTRY, 2012, 58 (03) :543-548
[6]   Vitamin D deficiency [J].
Holick, Michael F. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (03) :266-281
[7]   Automated Measurement of 25-OH Vitamin D3 on the Roche Modular E170 Analyzer [J].
Leino, Aila ;
Turpeinen, Ursula ;
Koskinen, Pertti .
CLINICAL CHEMISTRY, 2008, 54 (12) :2059-2062
[8]   The 2011 Report on Dietary Reference Intakes for Calcium and Vitamin D from the Institute of Medicine: What Clinicians Need to Know [J].
Ross, A. Catharine ;
Manson, JoAnn E. ;
Abrams, Steven A. ;
Aloia, John F. ;
Brannon, Patsy M. ;
Clinton, Steven K. ;
Durazo-Arvizu, Ramon A. ;
Gallagher, J. Christopher ;
Gallo, Richard L. ;
Jones, Glenville ;
Kovacs, Christopher S. ;
Mayne, Susan T. ;
Rosen, Clifford J. ;
Shapses, Sue A. .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2011, 96 (01) :53-58
[9]   Specifications for trueness and precision of a reference measurement system for serum/plasma 25-hydroxyvitamin D analysis [J].
Stoeckl, Dietmar ;
Sluss, Patrick M. ;
Thienpont, Linda M. .
CLINICA CHIMICA ACTA, 2009, 408 (1-2) :8-13
[10]   Measurement of 25-OH-vitamin D in human serum using liquid chromatography tandem-mass spectrometry with comparison to radioimmunoassay and automated immunoassay [J].
van den Ouweland, Johannes M. W. ;
Beijers, Antonius M. ;
Demacker, Pierre N. M. ;
van Daal, Henny .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (15-16) :1163-1168