The chronic defibrillation energy requirement (DER) is believed to remain clinically stable in patients with defibrillators. Six patients (two with an epicardial and four with a nonthoracotomy system) were identified with a rise in their chronic DER, which eliminated a 10-J safety margin, thus necessitating a defibrillator lead system revision. The mean increase in DER was 14.7 +/- 4J and was discovered at a mean of 16.0 +/- 18 months (range 2-41) following implantation. Management included placement of a defibrillator with a biphasic waveform, placement of an additional defibrillation electrode, or both. At 2 months following revision of the defibrillation system, a 10-J DER safety margin was present in each patient. In some patients, there is a progressive increase in the chronic DER with elimination of a 10-J safety margin necessitating revision of the defibrillation system. Routine reevaluation of the chronic DER, therefore, is necessary to identify these patients.
引用
收藏
页码:714 / 719
页数:6
相关论文
共 50 条
  • [21] CHRONIC ATENOLOL AND DEFIBRILLATION ENERGY-REQUIREMENTS
    LEMMER, JH
    SMITH, BG
    MOWER, MM
    DREWS, TA
    HULL, M
    KIENZLE, MG
    CIRCULATION, 1993, 88 (04) : 113 - 113
  • [22] Defibrillation energy requirements using a left anterior chest cutaneous to subcutaneous shocking vector: Implications for a total subcutaneous implantable defibrillator
    Burke, MC
    Coman, JA
    Cates, AW
    Lindstrom, CC
    Sandler, DA
    Kim, SS
    Knight, BP
    HEART RHYTHM, 2005, 2 (12) : 1332 - 1338
  • [23] Measurement of body-surface leakage energy of defibrillation shock by an implantable cardioverter defibrillator (ICD) system in humans
    Niwano, S
    Kojima, J
    Yoshizawa, N
    Inuo, K
    Hara, H
    Saito, J
    Moriguchi, M
    Kitano, Y
    Niwano, H
    Izumi, T
    EUROPACE 2001, 2001, : 137 - 141
  • [24] Unexpectedly high defibrillation thresholds in an active can implantable cardioverter defibrillator system
    Rao, A
    Reynolds, DW
    Beckman, KJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (07): : 1168 - 1169
  • [25] Defibrillation efficacy of downsized quadripolar implantable cardioverter-defibrillator lead: a randomized worldwide trial
    Ahern, T
    Canby, R
    Thamasett, S
    Kimber, S
    Roberts, D
    Eickhoff, C
    EUROPEAN HEART JOURNAL, 2000, 21 : 198 - 198
  • [26] THE EFFECTS OF NORMOTHERMIC AND HYPOTHERMIC CARDIOPULMONARY BYPASS ON DEFIBRILLATION ENERGY-REQUIREMENTS AND TRANSMYOCARDIAL IMPEDANCE - IMPLICATIONS FOR IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IMPLANTATION
    MARTIN, D
    GARCIA, J
    VALERI, CR
    KHURI, SF
    LIM, C
    DOURSOUNIAN, M
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 109 (05): : 981 - 988
  • [27] Atrial defibrillation success comparing a novel passive implantable atrial defibrillator with a routine transvenous atrial defibrillation system
    Manoharan, G
    Evans, N
    Allen, JD
    Anderson, J
    Adgey, AAJ
    EUROPEAN HEART JOURNAL, 2000, 21 : 558 - 558
  • [28] Implantable cardioverter/defibrillator:: long-term stability of the defibrillation threshold using a unipolar lead system ("active-can")
    Knuefermann, P
    Wolpert, C
    Spehl, S
    Korte, T
    Manz, M
    Lüderitz, B
    Jung, W
    ZEITSCHRIFT FUR KARDIOLOGIE, 2000, 89 (09): : 774 - 780
  • [29] PREDICTORS OF DEFIBRILLATION ENERGY-REQUIREMENTS WITH NONEPICARDIAL LEAD SYSTEMS
    KOPP, DE
    BLAKEMAN, BP
    KALL, JG
    OLSHANSKY, B
    KINDER, CA
    WILBER, DJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (02): : 253 - 260
  • [30] CHRONIC DEFIBRILLATION THRESHOLDS IN AN IMPLANTED TRANSVENOUS CARDIOVERTER DEFIBRILLATOR SYSTEM
    VENDITTI, FJ
    VASSOLAS, G
    MARTIN, D
    CIRCULATION, 1992, 86 (04) : 441 - 441