Targeted Data Extraction of the MS/MS Spectra Generated by Data-independent Acquisition: A New Concept for Consistent and Accurate Proteome Analysis

被引:1990
作者
Gillet, Ludovic C. [1 ]
Navarro, Pedro [1 ]
Tate, Stephen [2 ]
Roest, Hannes [1 ]
Selevsek, Nathalie [1 ]
Reiter, Lukas [1 ,3 ]
Bonner, Ron [2 ]
Aebersold, Ruedi [1 ,4 ]
机构
[1] ETH, Dept Biol, Inst Mol Syst Biol, CH-8093 Zurich, Switzerland
[2] ABSciex, Concord, ON L4K 4V8, Canada
[3] Biognosys AG, CH-8952 Schlieren, Switzerland
[4] Univ Zurich, Fac Sci, CH-8057 Zurich, Switzerland
基金
欧洲研究理事会;
关键词
MASS-SPECTROMETRY; PRECURSOR; VALIDATION; PEPTIDES; PROTEINS; MODEL; SRM;
D O I
10.1074/mcp.O111.016717
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Most proteomic studies use liquid chromatography coupled to tandem mass spectrometry to identify and quantify the peptides generated by the proteolysis of a biological sample. However, with the current methods it remains challenging to rapidly, consistently, reproducibly, accurately, and sensitively detect and quantify large fractions of proteomes across multiple samples. Here we present a new strategy that systematically queries sample sets for the presence and quantity of essentially any protein of interest. It consists of using the information available in fragment ion spectral libraries to mine the complete fragment ion maps generated using a data-independent acquisition method. For this study, the data were acquired on a fast, high resolution quadrupole-quadrupole time-of-flight (TOF) instrument by repeatedly cycling through 32 consecutive 25-Da precursor isolation windows (swaths). This SWATH MS acquisition setup generates, in a single sample injection, time-resolved fragment ion spectra for all the analytes detectable within the 400-1200 m/z precursor range and the user-defined retention time window. We show that suitable combinations of fragment ions extracted from these data sets are sufficiently specific to confidently identify query peptides over a dynamic range of 4 orders of magnitude, even if the precursors of the queried peptides are not detectable in the survey scans. We also show that queried peptides are quantified with a consistency and accuracy comparable with that of selected reaction monitoring, the gold standard proteomic quantification method. Moreover, targeted data extraction enables ad libitum quantification refinement and dynamic extension of protein probing by iterative re-mining of the once-and-forever acquired data sets. This combination of unbiased, broad range precursor ion fragmentation and targeted data extraction alleviates most constraints of present proteomic methods and should be equally applicable to the comprehensive analysis of other classes of analytes, beyond proteomics. Molecular & Cellular Proteomics 11: 10.1074/mcp.O111.016717, 1-17, 2012.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Multi-site assessment of the precision and reproducibility of multiple reaction monitoring-based measurements of proteins in plasma
    Addona, Terri A.
    Abbatiello, Susan E.
    Schilling, Birgit
    Skates, Steven J.
    Mani, D. R.
    Bunk, David M.
    Spiegelman, Clifford H.
    Zimmerman, Lisa J.
    Ham, Amy-Joan L.
    Keshishian, Hasmik
    Hall, Steven C.
    Allen, Simon
    Blackman, Ronald K.
    Borchers, Christoph H.
    Buck, Charles
    Cardasis, Helene L.
    Cusack, Michael P.
    Dodder, Nathan G.
    Gibson, Bradford W.
    Held, Jason M.
    Hiltke, Tara
    Jackson, Angela
    Johansen, Eric B.
    Kinsinger, Christopher R.
    Li, Jing
    Mesri, Mehdi
    Neubert, Thomas A.
    Niles, Richard K.
    Pulsipher, Trenton C.
    Ransohoff, David
    Rodriguez, Henry
    Rudnick, Paul A.
    Smith, Derek
    Tabb, David L.
    Tegeler, Tony J.
    Variyath, Asokan M.
    Vega-Montoto, Lorenzo J.
    Wahlander, Asa
    Waldemarson, Sofia
    Wang, Mu
    Whiteaker, Jeffrey R.
    Zhao, Lei
    Anderson, N. Leigh
    Fisher, Susan J.
    Liebler, Daniel C.
    Paulovich, Amanda G.
    Regnier, Fred E.
    Tempst, Paul
    Carr, Steven A.
    [J]. NATURE BIOTECHNOLOGY, 2009, 27 (07) : 633 - U85
  • [2] Mass spectrometry-based proteomics
    Aebersold, R
    Mann, M
    [J]. NATURE, 2003, 422 (6928) : 198 - 207
  • [3] Performance Characteristics of a New Hybrid Quadrupole Time-of-Flight Tandem Mass Spectrometer (TripleTOF 5600)
    Andrews, Genna L.
    Simons, Brigitte L.
    Young, J. Bryce
    Hawkridge, Adam M.
    Muddiman, David C.
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (13) : 5442 - 5446
  • [4] Deconvolution of Mixture Spectra from Ion-Trap Data-Independent-Acquisition Tandem Mass Spectrometry
    Bern, Marshall
    Finney, Gregory
    Hoopmann, Michael R.
    Merrihew, Gennifer
    Toth, Michael J.
    MacCoss, Michael J.
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (03) : 833 - 841
  • [5] Improving Protein and Proteome Coverage through Data-Independent Multiplexed Peptide Fragmentation
    Blackburn, Kevin
    Mbeunkui, Flaubert
    Mitra, Srijeet K.
    Mentzel, Tobias
    Goshe, Michael B.
    [J]. JOURNAL OF PROTEOME RESEARCH, 2010, 9 (07) : 3621 - 3637
  • [6] Advances in Mass Spectrometry for Lipidomics
    Blanksby, Stephen J.
    Mitchell, Todd W.
    [J]. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 3, 2010, 3 : 433 - 465
  • [7] XDIA: improving on the label-free data-independent analysis
    Carvalho, Paulo C.
    Han, Xuemei
    Xu, Tao
    Cociorva, Daniel
    Carvalho, Maria da Gloria
    Barbosa, Valmir C.
    Yates, John R., III
    [J]. BIOINFORMATICS, 2010, 26 (06) : 847 - 848
  • [8] Cancer genetics-guided discovery of serum biomarker signatures for diagnosis and prognosis of prostate cancer
    Cima, Igor
    Schiess, Ralph
    Wild, Peter
    Kaelin, Martin
    Schueffler, Peter
    Lange, Vinzenz
    Picotti, Paola
    Ossola, Reto
    Templeton, Arnoud
    Schubert, Olga
    Fuchs, Thomas
    Leippold, Thomas
    Wyler, Stephen
    Zehetner, Jens
    Jochum, Wolfram
    Buhmann, Joachim
    Cerny, Thomas
    Moch, Holger
    Gillessen, Silke
    Aebersold, Ruedi
    Krek, Wilhelm
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2011, 108 (08) : 3342 - 3347
  • [9] Using annotated peptide mass spectrum libraries for protein identification
    Craig, R.
    Cortens, J. C.
    Fenyo, D.
    Beavis, R. C.
    [J]. JOURNAL OF PROTEOME RESEARCH, 2006, 5 (08) : 1843 - 1849
  • [10] Comprehensive mass-spectrometry-based proteome quantification of haploid versus diploid yeast
    de Godoy, Lyris M. F.
    Olsen, Jesper V.
    Cox, Juergen
    Nielsen, Michael L.
    Hubner, Nina C.
    Froehlich, Florian
    Walther, Tobias C.
    Mann, Matthias
    [J]. NATURE, 2008, 455 (7217) : 1251 - U60