Gadolinium-Based Contrast Agents: What Does "Single-Dose" Mean Anymore?

被引:4
作者
Reeder, Scott B. [1 ,2 ,3 ,4 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Med Biomed Engn, Madison, WI USA
[4] Univ Wisconsin, Dept Med, Madison, WI USA
关键词
MR-ANGIOGRAPHY; GADOBENATE DIMEGLUMINE; EOB-DTPA; 3; TESLA; PHASE; SAFETY; MS-325;
D O I
10.1002/jmri.24352
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
[No abstract available]
引用
收藏
页码:1343 / 1345
页数:3
相关论文
共 10 条
  • [1] Liver MRI in the hepatocyte phase with gadolinium-EOB-DTPA: Does increasing the flip angle improve conspicuity and detection rate of hypointense lesions?
    Bashir, Mustafa R.
    Husarik, Daniela B.
    Ziemlewicz, Tim J.
    Gupta, Rajan T.
    Boll, Daniel T.
    Merkle, Elmar M.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (03) : 611 - 616
  • [2] Carotid MR angiography: Phase II study of safety and efficacy for MS-325
    Bluemke, DA
    Stillman, AE
    Bis, KG
    Grist, TM
    Baum, RA
    D'Agostino, R
    Malden, ES
    Pierro, JA
    Yucel, EK
    [J]. RADIOLOGY, 2001, 219 (01) : 114 - 122
  • [3] Liver Vessel Enhancement by Gd-BOPTA and Gd-EOB-DTPA: A Comparison in Healthy Volunteers
    Brismar, T. B.
    Dahlstrom, N.
    Edsborg, N.
    Persson, A.
    Smedby, O.
    Albiin, N.
    [J]. ACTA RADIOLOGICA, 2009, 50 (07) : 709 - 715
  • [4] Optimized High-Resolution Contrast-Enhanced Hepatobiliary Imaging at 3 Tesla: A Cross-over Comparison of Gadobenate Dimeglumine and Gadoxetic Acid
    Frydrychowicz, Alex
    Nagle, Scott K.
    D'Souza, Sharon L.
    Vigen, Karl K.
    Reeder, Scott B.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (03) : 585 - 594
  • [5] Steady-state and dynamic MR angiography with MS-325: Initial experience in humans
    Grist, TM
    Korosec, FR
    Peters, DC
    Witte, S
    Walovitch, RC
    Dolan, RP
    Bridson, WE
    Yucel, EK
    Mistretta, CA
    [J]. RADIOLOGY, 1998, 207 (02) : 539 - 544
  • [6] Double-Dose Gadoxetic Acid-Enhanced Magnetic Resonance Imaging in Patients With Chronic Liver Disease
    Motosugi, Utaroh
    Ichikawa, Tomoaki
    Sano, Katsuhiro
    Sou, Hironobu
    Onohara, Kojiro
    Muhi, Ali
    Kitamura, Takatoshi
    Amemiya, Fumitake
    Enomoto, Nobuyuki
    Matsuda, Masanori
    Asakawa, Masami
    Fujii, Hideki
    Araki, Tsutomu
    [J]. INVESTIGATIVE RADIOLOGY, 2011, 46 (02) : 141 - 145
  • [7] Relaxivity of gadopentetate dimeglumine (Magnevist), gadobutrol (Giadovist), and gadobenate dimeglumine (MultiHance) in human blood plasma at 0.2, 1.5, and 3 Tesla
    Pintaske, J
    Martirosian, P
    Graf, H
    Erb, G
    Lodemann, KP
    Claussen, CD
    Schick, F
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (03) : 213 - 221
  • [8] Nephrotoxicity of high-dose gadolinium compared with iodinated contrast
    Prince, MR
    Arnoldus, C
    Frisoli, JK
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01): : 162 - 166
  • [9] Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths
    Rohrer, M
    Bauer, H
    Mintorovitch, J
    Requardt, M
    Weinmann, HJ
    [J]. INVESTIGATIVE RADIOLOGY, 2005, 40 (11) : 715 - 724
  • [10] Safety and effectiveness of single- versus triple-dose gadodiamide injection-enhanced MR angiography of the abdomen:: A phase III double-blind multicenter study
    Thurnher, SA
    Capelastegui, A
    Del Olmo, FH
    Dondelinger, RF
    Gervás, C
    Jassoy, AG
    Keto, P
    Loewe, C
    Ludman, CN
    Marti-Bonmati, L
    Meusel, M
    da Cruz, JP
    Pruvo, JP
    Sanjuan, VM
    Vogl, T
    [J]. RADIOLOGY, 2001, 219 (01) : 137 - 146