Seismic Behavior of High-Strength Concrete-Filled FRP Tube Columns

被引:113
作者
Idris, Yunita [1 ]
Ozbakkaloglu, Togay [1 ]
机构
[1] Univ Adelaide, Sch Civil Environm & Min Engn, Adelaide, SA 5005, Australia
关键词
Fiber-reinforced polymer; High-strength concrete; Confinement; Columns; Tubes; Lateral drift; FIBER-REINFORCED POLYMER; RC COLUMNS; COMPRESSIVE BEHAVIOR; AXIAL-COMPRESSION; CYCLIC BEHAVIOR; PERFORMANCE; SQUARE; JACKETS; MANUFACTURE; COMPOSITES;
D O I
10.1061/(ASCE)CC.1943-5614.0000388
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper reports on an experimental program that investigated the seismic behavior of high-strength concrete (HSC)-filled fiber-reinforced-polymer (FRP) tubes (HSCFFTs), designed to perform as building columns. Five square and one circular concrete-filled FRP tube (CFFT) columns were tested under constant axial compression and reversed-cyclic lateral loading. The main parameters of the experimental study were the axial load level, column cross-sectional shape, concrete strength, amount and type of FRP confinement, and FRP tube corner radius. Examination of the test data resulted in a number of significant conclusions with regard to the influence of the investigated column parameters on the performance of CFFT columns. Of primary importance, the results indicate that square HSCFFT columns are capable of developing very high inelastic deformation capacities under simulated seismic loading. The results also indicate that increasing the FRP tube corner radius up to a certain threshold leads to a significant increase in column lateral drift capacities. By contrast, increasing the corner radius beyond that threshold value provides no additional improvement in the hysteretic behavior of square CFFT columns. The influence of the cross-sectional shape is found to be significant, with the circular CFFT exhibiting a larger lateral drift capacity compared with the companion square CFFTs. A set of comparable columns from previous studies has also been included in the discussion to clarify the influence of each parameter on the column behavior. The results of the experimental program are presented together with a discussion on the influence of the main parameters on the seismic behavior of CFFT columns. (C) 2013 American Society of Civil Engineers.
引用
收藏
页数:13
相关论文
共 48 条
[1]  
Bae SJ, 2008, ACI STRUCT J, V105, P290
[2]   Textile-Reinforced Mortar versus FRP Jacketing in Seismic Retrofitting of RC Columns with Continuous or Lap-Spliced Deformed Bars [J].
Bournas, D. A. ;
Triantafillou, T. C. ;
Zygouris, K. ;
Stavropoulos, F. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2009, 13 (05) :360-371
[3]   Seismic retrofitting of columns with lap spliced smooth bars through FRP or concrete jackets [J].
Bousias, Stathis ;
Spathis, Alexis-Loukas ;
Fardis, Michael N. .
JOURNAL OF EARTHQUAKE ENGINEERING, 2007, 11 (05) :653-674
[4]  
Chung YS, 2008, ACI STRUCT J, V105, P87
[5]  
Compos J., 2002, ACI STRUCT J, V99, P72
[6]   Experimental Study of Normal- and High-Strength Concrete Confined with Fiber-Reinforced Polymers [J].
Cui, C. ;
Sheikh, S. A. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (05) :553-561
[7]   Seismic retrofit of square RC columns with polyethylene terephthalate (PET) fibre reinforced polymer composites [J].
Dai, Jian-Guo ;
Lam, Lik ;
Ueda, Tamon .
CONSTRUCTION AND BUILDING MATERIALS, 2012, 27 (01) :206-217
[8]   Normal- and High-Strength Concrete Circular Elements Wrapped with FRP Composites [J].
Eid, R. ;
Roy, N. ;
Paultre, P. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2009, 13 (02) :113-124
[9]   Rectangular filament-wound glass fiber reinforced polymer tubes filled with concrete under flexural and axial loading: Experimental investigation [J].
Fam, A ;
Schnerch, D ;
Rizkalla, S .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2005, 9 (01) :25-33
[10]  
Fam AZ, 2001, ACI STRUCT J, V98, P451